Manhattan · Block 921 · Lot 19 · 10003

333 East 14 Street

17 floors · 207 apartments · 197,904 sq ft · built 1965 · class D4 · owner of record: Stuyvesant Owners Inc

39open violations
$15,000ECB/OATH penalties owed
2HPD class C (immediately hazardous)
43dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 43 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 43 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 59 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 197,904 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 164 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 164 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 287 days
Registered through 2027-09-01
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. Agency page

Feb 21, 2029
in 826 days
Filing window not open yet
Energy audit and retro-commissioning (2031) Likely applies
Local Law 87 · Calendar year 2031
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 921). Agency page

Dec 31, 2031
in 1869 days
Next due 2031
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-08 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (4) · $15,000 owed
IssuedViolationHearingBalance
Jul 29, 2026Construction CLASS - 3
MISCELLANEOUS VIOLATIONS. ATOI OBSERVED LOCAL LAW 110 NOT IN COMPLIANCE. SERVED NOTICE OF VIOLATION# 39171514R ISSUED ON 12/24/2025 FOR ROOF VENTILATION W/O A PERMIT, WAS NOT POSTED IN LOBBY PER LOCAL LAW 110.
#39198292K
Oct 8, 2026
ADMIT/IN-VIO
$0
Dec 24, 2025Construction CLASS - 2
NEGATIVE AIR PRESSURE HAS BEEN OBSERVED IN THE BATHROOMS AND KITCHEN EXHAUSTS LOCATED IN COMBINED APARTMENTS 6A AND 6N.; BC -MISC, COMPLY WITH CODE; ADJUST THE INTAKE AND EXHAUST AIRFLOW FOR THE BATHROOMS/KITCH
#39175020P
Dec 10, 2026
PENDING
$1,250
Dec 24, 2025Construction CLASS - 2
OBSERVED THE FOLLOWING MECHANICAL VENTILATION FANS INSTALLED ON THE ROOF WITHOUT PROPER DOB PERMITS. 1-GREENHECK FAN MODEL-GB-360 -15-1-46-X AND 1- JENCO FAN MODEL - SDB22QH3S. OBTAIN ALL PERMITS AS PER AC-28-1
#39171514R
Nov 10, 2026
PENDING
$1,250
Jul 20, 2021Unknown CLASS - 1
NO SST 40 HR CERTIFICATES.AT TIME OF INSPECTION OF ACTIVE 17 STORY ALT 2 QITH 6 WORKERS REQUESTED FOR SST FOUR WORKERS UNABLE TO PROVIDE MR SERGIO E MACANCELLA,VICTOR O MINCHALA.JORGE B PAIAN AND HOSE GUALLPA
#35580480J
Sep 30, 2021
DEFAULT
$12,500
DOB (2)
IssuedViolationStatus
Feb 25, 2026CONSTRUCTION
FAILURE TO MAINTAIN EXHAUST/ VENTILATION SYSTEM INSIDE APT. 6A/6N
#26-00608
DOB VIOLATION - ACTIVE
May 4, 2004ELEVATOR

#9444/199966
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Nov 25, 2024Parking Structures FTF-PS-INITL
Failure to file sub cycle 1A compliance report by 12/31/2023
Active
HPD (33) · C 2 · B 27 · A 4
IssuedClassViolationCorrect by
Oct 26, 2026BApt 6N · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTNov 30, 2026
Oct 26, 2026CApt 6N · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTNov 9, 2026
Oct 26, 2026BApt 6N · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE BATHROOM LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTNov 30, 2026
Oct 26, 2026BApt 6N · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTNov 30, 2026
Oct 26, 2026BApt 6N · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTNov 30, 2026
Oct 6, 2026BApt 6N · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18990341 ISSUED 03-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CNov 10, 2026
Sep 30, 2026BApt 6N · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQFT AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18966714 ISSUED 29-MAY-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODNov 4, 2026
Jun 22, 2026CApt 6A · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH SET AT 2ND DOOR ENYTRANCE TO APT 6N IN THE ENTRANCE LOCATED AT APT 6A, 1st STORY, 4th APARTMENT FROM WEST AT NORTHJul 6, 2026
Jun 17, 2026AApt 6N · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHSep 20, 2026
Jun 17, 2026BApt 6N · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT SOUTH WALL IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHJul 22, 2026
Jun 17, 2026BApt 6N · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHJul 22, 2026
Jun 17, 2026BApt 6N · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT WEST WALL IN THE 1st BATHROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHJul 22, 2026
Jun 17, 2026AApt 6N · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHSep 20, 2026
Jun 17, 2026AApt 6N · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHSep 20, 2026
Jun 2, 2026BApt 6N · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM AT SOUTH WALL IN THE 4th BATHROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHJul 7, 2026
Jun 2, 2026AApt 6N · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHSep 5, 2026
Jun 2, 2026BApt 6N · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM AT WEST WALL IN THE 2nd BATHROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHJul 7, 2026
May 27, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT LAUNDRY ROOM DOOR AT PUBLIC HALL, 1st STORYJul 1, 2026
May 27, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT FIRE STAIRS ''A'' DOOR AT PUBLIC HALL, 1st STORYJul 1, 2026
May 4, 2026BApt 6NA · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENT AT WEST WALL IN THE BATHROOM LOCATED AT APT 6NA, 6th STORY, 3rd APARTMENT FROM WEST AT NORTHJun 8, 2026
Apr 27, 2026BApt 6NA · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENT AT WEST WALL IN THE BATHROOM LOCATED AT APT 6NA, 6th STORY, 2nd APARTMENT FROM WEST AT NORTHJun 1, 2026
Apr 23, 2026BApt 6N · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INOPERATIVE VENTILATION SYSTEM IN THE BATHROOM LOCATED AT APT 6N, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHMay 28, 2026
Apr 6, 2026B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 20SQ FEET AT EAST WALL AT PUBLIC HALL, 1st STORY ORIGINAL VIOLATION 18482547 ISSUED 04-DEC-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) or (b).May 11, 2026
Nov 27, 2019BApt 6C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE KITCHEN LOCATED AT APT 6C, 6th STORY, 6th APARTMENT FROM WEST AT NORTHJan 1, 2020
Nov 27, 2019BApt 6C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE 4th ROOM FROM EAST LOCATED AT APT 6C, 6th STORY, 6th APARTMENT FROM WEST AT NORTHJan 1, 2020
Nov 27, 2019BApt 6C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK THROUGHOUT CEILING IN THE KITCHEN LOCATED AT APT 6C, 6th STORY, 6th APARTMENT FROM WEST AT NORTHJan 1, 2020
Nov 27, 2019BApt 6C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE FOYER LOCATED AT APT 6C, 6th STORY, 6th APARTMENT FROM WEST AT NORTHJan 1, 2020
Nov 27, 2019BApt 6C · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE IGNITION COIL AT RANGE IN THE KITCHEN LOCATED AT APT 6C, 6th STORY, 6th APARTMENT FROM WEST AT NORTHJan 1, 2020
Nov 27, 2019BApt 6C · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM EAST LOCATED AT APT 6C, 6th STORY, 6th APARTMENT FROM WEST AT NORTHJan 1, 2020
Nov 27, 2019BApt 6C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE 1st BATHROOM FROM NORTH LOCATED AT APT 6C, 6th STORY, 6th APARTMENT FROM WEST AT NORTHJan 1, 2020
Nov 27, 2019BApt 6C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE 2nd ROOM FROM EAST LOCATED AT APT 6C, 6th STORY, 6th APARTMENT FROM WEST AT NORTHJan 1, 2020
Nov 27, 2019BApt 6C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND ALL WALLS IN THE PRIVATE HALLWAY LOCATED AT APT 6C, 6th STORY, 6th APARTMENT FROM WEST AT NORTHJan 1, 2020
Nov 27, 2019BApt 6C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE PRIVATE HALLWAY LOCATED AT APT 6C, 6th STORY, 6th APARTMENT FROM WEST AT NORTHJan 1, 2020

Issued in the last 120 days

DateSourceWhatNow
Oct 26, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE 2nd ROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Oct 26, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Oct 26, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL IN THE BATHROOM LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Oct 26, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Oct 26, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM NORTH AT EASTOpen
Oct 6, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18990341 ISSUED 03-JUN-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE COpen
Sep 30, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQFT AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 6N, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18966714 ISSUED 29-MAY-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODOpen
Aug 5, 2026ECBConstruction: AT TIME OF INSP, NOTICE OF VIO # 39175020P ISSUED ON 12/24/2025 FOR BTHRM AND KIT EXHAUSTS FOR COMBINED UNITS 6A AND 6N WAS NOT DIST. TO RESIDENTS OF OCCUPIED DWELLING UNIT WHERE VIO WAS OBSERVED, OR TO OCCUPIEClosed
Jul 29, 2026ECBConstruction: MISCELLANEOUS VIOLATIONS. ATOI OBSERVED LOCAL LAW 110 NOT IN COMPLIANCE. SERVED NOTICE OF VIOLATION# 39171514R ISSUED ON 12/24/2025 FOR ROOF VENTILATION W/O A PERMIT, WAS NOT POSTED IN LOBBY PER LOCAL LAW 110.Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 5:16 PM ET. BBL 1009210019.