2 floors · 17,922 sq ft · built 1998 · class H4 · owner of record: Hillgun Realty Corp.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2024-10-08 (Accepted). Agency page | Dec 31, 2026 in 68 days | 1 of 1 without an accepted 2026 report yet |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 433 days | Next cycle year 2027 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 14, 1998 | Construction Non-Hazardous MECHANICAL DEMOLITION WORK WITHOUT A PERMIT NOTED: DEMOLITION OF SAID PREMISE BY USE OF A DOZER WITH BOOM. DEPT OF BUILDING SHOW NO PERMIT FOR MECH. DEMO WAS ISSUED FOR SAID PREMISE. REMEDY: OBTAIN NECESSARY #34178257P | Sep 22, 2000 WRITTEN OFF | $0 |
| Dec 8, 1993 | Construction Non-Hazardous ALTERED BUILDING OCCUPIED WITHOUTA VALID COFO. ALTERATION 457-87. REMEDY:OBTAIN A VALID COFO. #34102538K | Sep 22, 2000 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 30, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION #09110 | DOB VIOLATION - ACTIVE |
| Jan 31, 2005 | LOCAL LAW 62/91 - BOILERS #09431 | DOB VIOLATION - ACTIVE |
| May 25, 2004 | CONSTRUCTION #1201PK | DOB VIOLATION - ACTIVE |
| Feb 13, 2004 | LOCAL LAW 62/91 - BOILERS #10150 | DOB VIOLATION - ACTIVE |
| Oct 12, 1993 | CONSTRUCTION #11DB01 | DOB VIOLATION - ACTIVE |
| May 17, 1993 | CONSTRUCTION #11W02 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jun 30, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jan 31, 2005 | Boiler LL6291 | Active |
| Jan 31, 2005 | Boiler LL6291 | Active |
| Feb 13, 2004 | Boiler LL6291 | Active |
| Feb 13, 2004 | Boiler LL6291 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 12:35 AM ET. BBL 2047320012.