Manhattan · Block 939 · Lot 20 · 10016

331 East 33 Street

5 floors · 21 apartments · 9,200 sq ft · built 1910 · class C5 · owner of record: 331 East 33rd Llc

14open violations
$0ECB/OATH penalties owed
7HPD class C (immediately hazardous)
50dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 50 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 50 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 50 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 66 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 294 days
Registered through 2027-09-01
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-11 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (3)
IssuedViolationHearingBalance
Dec 1, 2023Construction CLASS - 1
OCCUPANCY CONTRARY TO CERTIFICATE OF OCCUPANCY. OBSERVED TWO CLASS A APARTMENTS IN BASEMENT. C OF O#74076, LIST ONE APARTMENT., DISCONTINUE ILLEGAL OCCUPANCY OR AMEND C OF O; AMEND C OF O
#39100502L
Feb 22, 2024
IN VIOLATION
$0
Dec 1, 2023Construction CLASS - 2
OBSERVED IN BASEMENT BY THE GAS METERS USING LAMP WICK ON GAS LINE WHICH IS CONTRARY TO FGC 403.9.3, REPAIR AND/OR REPLACE
#39100498H
Oct 11, 2024
IN VIOLATION
$0
Dec 28, 2013Construction CLASS - 2
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE COFO. NOTE: COFO #74076 AND APPROVED PLANS DATE 9/17/13 WITH APPLICATION #121755573 INDICATE ONE CLASS"A"APT IN RIGHT SIDE OF BASEMENT AND STORAGE.NOW AT TIME OF INSPE
#35073862Z
Feb 28, 2014
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
May 15, 2014LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
#04286
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
May 15, 2014Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT
Active
HPD (8) · C 7 · B 1 · A 0
IssuedClassViolationCorrect by
Mar 23, 2026CApt 1A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTMar 29, 2026
Mar 23, 2026CApt 3C · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHMar 29, 2026
Mar 23, 2026CApt 5A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT GAS RANGE IN THE KITCHEN LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTMar 29, 2026
Sep 8, 2025CApt 5A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTOct 4, 2025
Sep 8, 2025CApt 5A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5A, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTOct 4, 2025
Apr 22, 2024CApt 1A · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 1A, 1st STORY, 1st APARTMENT FROM SOUTH AT WESTApr 28, 2024
Nov 30, 2023CApt 3C · § 27-2070 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF GAS TO THE FIXTURES AT RANGE IN THE KITCHEN LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM WEST AT NORTHDec 6, 2023
Jun 5, 2008BApt 1C · D26-10.01, 10.05 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE 1ST STY REAR APT 1C REAR ROOM WEST WINDOW. , SECTION '' ''Jul 10, 2008

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 11, 2026, 5:32 PM ET. BBL 1009390020.