5 floors · 100 apartments · 23,492 sq ft · built 1900 · class N2 · owner of record: Nyc Department Of Homeless Services
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2015-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 70 days | Annual |
| Annual boiler inspection (5 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-10-30 (Accepted). Agency page | Dec 31, 2026 in 70 days | 5 of 5 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 86 days | Annual |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 801 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Dec 16, 2025 | Construction CLASS - 2 ON 5TH FLOOR INSTALLED NEW PIPING FOR SHOWER AND SINKS IN BATHROOM 95 PERCENT WORK COMPLETED NO PLUMBING PERMIT ON FILE, OBTAIN ALL PERMITS #39170661M | Dec 24, 2025 POP/IN-VIO | $0 |
| Dec 16, 2025 | Construction CLASS - 2 OBSERVED ON THE THIRD FLOOR IN STAIRCASE A SPRINKLER HEAD IS DAMAGED AND ON THE FIRST FLOOR SPRINKLER HEAD CAP IS PAINTED TO CELLING. IN BASEMENT SPRINKLER MAIN VALVE AND WATER MAIN VALVE NOT ACCESSIBLE. ALSO T #39170660K | Dec 24, 2025 POP/IN-VIO | $0 |
| Mar 13, 2025 | Construction CLASS - 1 UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED FLAMMABLE CONTAINERS IN FIRE PUMP ROOM. (CAR ANTI FREEZE, DIESEL FUEL, POWER STEERING FUEL), MAINTAIN STORAGE IN COMPLIANCE WITH FIRE CODE #39141472K | Mar 25, 2025 POP/IN-VIO | $0 |
| Mar 13, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED BENT SPRINKLER HEAD AT 3RD FLOOR STAIRWELL LANDING. POTENTIAL FIRE HAZARD., REPAIR AND/OR REPLACE #39141475X | Mar 25, 2025 POP/IN-VIO | $0 |
| Mar 13, 2025 | Construction CLASS - 1 FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED PUMP ROOM OBSTRUCTED WITH CONSTRUCTION MATERIAL AND PIPES AT DOORWAY. POTENTIAL FIRE HAZARD., REMOVE OBSTRUCTION #39141474Y | Mar 18, 2025 POP/IN-VIO | $0 |
| Mar 13, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1 (2014 CODE); 27-371; BC 1008.1.9 (2014 CODE); BC 1010.1.8 (2022 CODE); BC 1010.1.9 (2022 CODE). OBSERV #39141476H | Mar 25, 2025 POP/IN-VIO | $0 |
| Mar 13, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED AC INSTALLED INTO WALL AT 1ST FLOOR AND BASEMENT AND HOLE PENETRATIONS T #39141473M | Mar 25, 2025 POP/IN-VIO | $0 |
| May 15, 2024 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #39074955H ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH COMMISSI #39114411N | May 30, 2024 POP/IN-VIO | $0 |
| May 15, 2024 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39074958N ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE TO FILE PERMI #39114407K | May 30, 2024 POP/IN-VIO | $0 |
| May 15, 2024 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39074958P ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH COMMISSI #39114410L | Jul 9, 2024 POP/IN-VIO | $0 |
| Mar 27, 2024 | Construction CLASS - 2 OBSERVED IN THE BOILER ROOM LOCATED IN THE BASEMENT/CELLAR ACTIVE LEAK ON PIPING FROM TEMP BOILER. AS PER 102.3 OF THE PLUMBING CODE MAINTENANCE. INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE #39110101J | May 29, 2024 POP/IN-VIO | $0 |
| Mar 27, 2024 | Construction CLASS - 2 OBSERVED IN THE BASEMENT/CELLAR JIM CAPS INSTALLED ON CAST IRON FITTINGS., REPAIR AND/OR REPLACE #39110100H | May 29, 2024 POP/IN-VIO | $0 |
| Dec 15, 2023 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#39074955H ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE #39101586M | Jan 2, 2024 POP/IN-VIO | $0 |
| Dec 15, 2023 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#39074958N ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE #39101589H | Jan 2, 2024 POP/IN-VIO | $0 |
| Dec 15, 2023 | Construction CLASS - 1 UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #39074959P ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILUR #39101596X | Jan 2, 2024 POP/IN-VIO | $0 |
| Dec 2, 2022 | Boilers CLASS - 2 AS PER ONE AO SMITH DOMESTIC HOT WATER BOILER, YEAR BUILT 2014, SERIAL NO. 1433M001233. BOILER NOT REGISTERED. APPLY FOR PROPER PERMITS, CORRECT VIOLATING CONDITIONS, CALL FOR AN INSPECTION. #39074976R | Dec 6, 2022 POP/IN-VIO | $0 |
| Dec 2, 2022 | Elevators CLASS - 2 AS PER ONE NATURAL GAS BURNHAM BOILER, YEAR BUILT 2006. SERIAL NO. 64938167; BOILER NOT REGISTERED. APPLY FOR PROPER PERMITS, CORRECT VIOLATING CONDITIONS, CALL FOR AN INSPECTION. #39074975P | Dec 6, 2022 POP/IN-VIO | $0 |
| Dec 2, 2022 | Boilers CLASS - 2 AS PER ONE NATURAL GAS, BURNHAM CAST IRON BOILER, YEAR BUILT 2015, SERIAL NO. 65539938; BOILER NOT REGISTERED. APPLY FOR PROPER PERMITS, CORRECT VIOLATING CONDITIONS, CALL FOR AN INSPECTION. #39074974N | Dec 6, 2022 POP/IN-VIO | $0 |
| Nov 30, 2022 | Construction CLASS - 2 AT FIRST FLOOR, MECHANICAL ROOM, ACTIVE WATER FILTRATION FROM THE ROOF TO THE INTERIOR OF THE MECHANICAL ROOM., REPAIR AND/OR REPLACE #39074960M | Dec 6, 2022 POP/IN-VIO | $0 |
| Nov 30, 2022 | Construction CLASS - 1 OBSERVED: AT EXPOSURE # 3, BACK YARD, DISCHARD FIRE SCAPE IS BEING OBSTRUCTED BY MATERIALS STORED. ALSO, AT FIRST FL, EXIT TO BACKYARD, A DEFECTIVE WOODEN STAIRCASE WAS BUILT, BEING AN EMINENT RISK OF ACCIDENT #39074955H | Dec 8, 2022 POP/IN-VIO | $0 |
| Nov 30, 2022 | Construction CLASS - 2 OBSERVED: AT FIRST FLOOR, MECHANICAL ROOM, WOODEN STRUCTURE THAT SUPPORTS THE ROOF OF THE MECHANICAL ROOM, IS BEING PROVISIONALLY SUPPORTED BY DEFECTIVE WOODEN COLUMNS, WITHOUT PROPER ANCHORING AND INSTALLATION #39074956J | Dec 6, 2022 POP/IN-VIO | $0 |
| Nov 30, 2022 | Construction CLASS - 1 OBSERVED: AT FIRST FL, MECHANICAL ROOM, FLAMMABLE MATERIAL IS BEING STORED. ALSO, WOODEN STRUCTURE THAT SUPPORTS THE CEILING (COLUMNS) AND CEILING BEAMS HAVE NO FIRE PROTECTION, ROOM CONDITION WITH EASY PROPAGA #39074959P | Dec 6, 2022 POP/IN-VIO | $0 |
| Nov 30, 2022 | Construction CLASS - 1 OBSERVED: AT FIRST FLOOR, MECHANICAL ROOM, WOODEN STRUCTURE THAT SUPPORTS THE ROOF OF THE MECHANICAL ROOM, IS BEING PROVISIONALLY SUPPORTED BY DEFECTIVE WOODEN COLUMNS, WITHOUT PROPER ANCHORING AND INSTALLATION #39074958N | Dec 6, 2022 POP/IN-VIO | $0 |
| Nov 30, 2022 | Construction CLASS - 2 OBSERVED: AT CELLAR LEVEL, FIRE PROOF WALLS & CEILING SHOWS SEVERAL HOLES, OPENINGS DUE TO CEILING DAMAGE OR PIPE PENETRATION WITHOUT FIRE STOPPING PROVIDED. PREVIOUS VIOLATION # 39048680Z., PROVIDE/MAINTAIN FI #39074957L | Dec 6, 2022 POP/IN-VIO | $0 |
| Apr 7, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:OBSERVED:AT 1ST FL,MECHANICAL ROOM,EXPOSED WOOD CEILING W/O FIRE BARRIER,CEILING SUPPORTED BY DEFECTIVE WOODEN COLUMNS(CRACKS). ALSO,THE STRUCTURE(SHORING) #35650620N | Jul 21, 2022 POP/IN-VIO | $0 |
| Apr 7, 2022 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY OR BUILDING DEPT RECORDS.OBSERVED CERTIFICATE OF OCCUPANCY #113386/1997 INDICATES AT CELLAR LEVEL BOILER ROOM FIRE PUMPRM GENERATOR PUMP ROOM & STO #35650619X | Jul 21, 2022 POP/IN-VIO | $0 |
| Oct 4, 2021 | Construction CLASS - 2 NOTED: OBSERVED AT FIRST FLOOR LEVEL (REAR) MECHANICAL ROOM, 6"X6" WOODEN VERTICAL POST THAT SUPPORTS THE CEILING IS SHIFTING OFF OF THE CEILING JOISTS, JOIST IS RESTING ON BEAM BY APPROXIMATELY 1 INCH., REPAIR #39048679L | Oct 15, 2021 POP/IN-VIO | $0 |
| Oct 4, 2021 | Construction CLASS - 2 NOTED: OBSERVED AT CELLAR'S, GENERATOR/FIRE PUMP ROOM, FIREPROOF CEILING TILES ARE MISSING AT VARIOUS LOCATIONS EXPOSING WOODEN JOISTS FROM FLOOR ABOVE., PROVIDE/MAINTAIN FIRE STOPPING #39048680Z | Oct 15, 2021 POP/IN-VIO | $0 |
| Sep 25, 2019 | Construction CLASS - 2 NOTE: OBSERVED AT FIRST FLOOR MECHANICAL ROOM, 6"X6" WOODEN SUPPORT MEMBERS THAT SUPPORT THE CEILING HAVE SHIFTED AND ARE BARELY ON THE HORIZONTAL BEAM. , REPAIR AND/OR REPLACE #39010119J | Oct 4, 2019 POP/IN-VIO | $0 |
| Sep 25, 2019 | Construction CLASS - 2 NOTED: OBSERVED AT FIRE PUMP/GENERATOR ROOM AT CELLAR, FIREPROOF CEILING TILES ARE MISSING THROUGHOUT ROOM AND EXPOSING WOODEN JOISTS AND SUB-FLOORING, ALSO ABOVE GAS METER. , PROVIDE/MAINTAIN FIRE STOPPING #39010120R | Oct 4, 2019 POP/IN-VIO | $0 |
| Sep 25, 2018 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED ON 9/25/18 AT ABOVE ADDRESS GAS LEAK ON DRESSER COUPLIN ON THE SERVICE SIDE OF THE BUILDING. CON-ED CALLED AND LOCKED THE VALVE. REMEDY:REPLACE AN #35361829N | Nov 29, 2018 POP/IN-VIO | $0 |
| Sep 25, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:NO FIRE STOPPINGPER BC 712.3;27-345. NOTED:AT CELLAR, IN FIRE PUMP ROOM, DROP CEILING TILES MISSING AT CEILING ELIMINATING FIRE STOPPING. REMEDY:PROVIDE/MAI #35361385L | Nov 29, 2018 POP/IN-VIO | $0 |
| Sep 25, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT 1ST STORY IN MECHANICAL ROOM, WATER PENETRATING CEILING WITH AN ACTIVE FLOW. REMEDY: REPAIR AND/OR REPLACE #35361383H | Nov 29, 2018 POP/IN-VIO | $0 |
| Mar 8, 2018 | Construction CLASS - 2 WORK W/OUT A PERMIT.OBSERVED ON THE UPPERMOST FL IN THE STIRWELL WHERETHE INSP TEST(VALVE)IS INSTALLED A PRESSURE GUAGE HAS BEEN INSTALLED W/OUT A PERMI DOB RECORDS DO NOT SHOW ANY PERMITS/APPROVALS ISSUED FOR #35322072Z | May 17, 2018 POP/IN-VIO | $0 |
| Mar 8, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED AT FIRST FLOOR MECHANICAL ROOM,6INCH X 6INCH POSTS THAT ARE BEING USED TO SUPPORT AND ARRY THE LOAD OF THE SMALL ROOF AT THE REAR HAVE SHIFTE #35317574M | May 31, 2018 POP/IN-VIO | $0 |
| Mar 8, 2018 | Plumbing CLASS - 1 FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.OBSERVED A PRESSURE GAUGE INSTALLED @THE UPPERMOST PART OF THE AUTOMATIC FIRE SPRINKLER SYSTEM HOWEVER DOB RECORDS DOES NOT SHOW ANY TEST BEING PERFORMED ON #35322073K | May 17, 2018 POP/IN-VIO | $0 |
| Mar 8, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO FIRE STOPPINGPER BC 712.3;27-345.NOTED:OBSERVED AT CELLAR-WITHIN FIRE PUMP ROOM/GENERATOR ROOM PIPE/CONDUIT PENETRATIONS,SECTIONS OF ACOUSTICAL CEILING T #35317573K | May 31, 2018 POP/IN-VIO | $0 |
| Aug 31, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.OBSERVED @TOP OF STAIRWELL INSP TEST W/NO PRESSURE GAUGE INSTALLED AS IS REQUIRED.REM:REPAIR &/OR REPLACE. PHOTO TAKEN. #35290311N | Dec 21, 2017 POP/IN-VIO | $0 |
| Aug 31, 2017 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER:NOTED.FIRE STOP MISSING IN THE FIRE PUMP ROOM THRU OUT ROOM HOLE IN WALL & CEILING,(GAS) & FUEL TANK ALSO IN ROOM.REM:PROVIDE/MAINTAIN FIRE STOPPING. #35290653N | Dec 21, 2017 POP/IN-VIO | $0 |
| Jul 19, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN BLDG CODE COMPLIANT: NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: @ CELLAR BOILER ROOM, APPROX 3' X 3' AREA OF METAL CEILING IS CORRODED/OPEN/MISING EXPOSING CONCEALED SPACE W/ WOOD JOISTS #35200983Y | Sep 15, 2016 POP/IN-VIO | $0 |
| Jun 17, 2016 | Construction CLASS - 1 WORK W/O PERMIT ON SANDPIPE TIME OF INSPECTION 1:15PM. AT TIME OF INSPECTION I OBSERVED DISCONNECTED AND CAPPED FIRE HOSE CONNECTION FOR FIRE DEPT USE ON EACH FLOOR FROM 1ST THROUGHOUT 5TH ON EXISTING STANDPIPE #35181049Y | Sep 15, 2016 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 21, 1991 | CONSTRUCTION #A4BL01 | VIOLATION UNSERVED ECB-ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 27, 2017 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACOUSTIC CEILING , 2nd STORY | Mar 2, 2018 |
| Nov 27, 2017 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACOUSTIC CEILING ENTIRE STORY , 5th STORY | Mar 2, 2018 |
| Nov 27, 2017 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACOUSTIC CEILING , 1st STORY | Mar 2, 2018 |
| Nov 8, 2017 | A | Apt 501 · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACOUSTIC CEILING ENTIRE STORY LOCATED AT DORMITORY 501, 5th STORY | Feb 11, 2018 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 22, 2026, 12:07 AM ET. BBL 1004580004.