Manhattan · Block 458 · Lot 4 · 10003

331 Bowery

5 floors · 100 apartments · 23,492 sq ft · built 1900 · class N2 · owner of record: Nyc Department Of Homeless Services

46open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2015-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 70 days
Annual
Annual boiler inspection (5 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-10-30 (Accepted). Agency page

Dec 31, 2026
in 70 days
5 of 5 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 86 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 801 days
Next cycle year 2028

Open violations

ECB / OATH (41)
IssuedViolationHearingBalance
Dec 16, 2025Construction CLASS - 2
ON 5TH FLOOR INSTALLED NEW PIPING FOR SHOWER AND SINKS IN BATHROOM 95 PERCENT WORK COMPLETED NO PLUMBING PERMIT ON FILE, OBTAIN ALL PERMITS
#39170661M
Dec 24, 2025
POP/IN-VIO
$0
Dec 16, 2025Construction CLASS - 2
OBSERVED ON THE THIRD FLOOR IN STAIRCASE A SPRINKLER HEAD IS DAMAGED AND ON THE FIRST FLOOR SPRINKLER HEAD CAP IS PAINTED TO CELLING. IN BASEMENT SPRINKLER MAIN VALVE AND WATER MAIN VALVE NOT ACCESSIBLE. ALSO T
#39170660K
Dec 24, 2025
POP/IN-VIO
$0
Mar 13, 2025Construction CLASS - 1
UNSAFE STORAGE OF COMBUSTIBLE MATERIAL AND EQUIPMENT. OBSERVED FLAMMABLE CONTAINERS IN FIRE PUMP ROOM. (CAR ANTI FREEZE, DIESEL FUEL, POWER STEERING FUEL), MAINTAIN STORAGE IN COMPLIANCE WITH FIRE CODE
#39141472K
Mar 25, 2025
POP/IN-VIO
$0
Mar 13, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED BENT SPRINKLER HEAD AT 3RD FLOOR STAIRWELL LANDING. POTENTIAL FIRE HAZARD., REPAIR AND/OR REPLACE
#39141475X
Mar 25, 2025
POP/IN-VIO
$0
Mar 13, 2025Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. OBSERVED PUMP ROOM OBSTRUCTED WITH CONSTRUCTION MATERIAL AND PIPES AT DOORWAY. POTENTIAL FIRE HAZARD., REMOVE OBSTRUCTION
#39141474Y
Mar 18, 2025
POP/IN-VIO
$0
Mar 13, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: USE OF PROHIBITED DOOR AND/OR HARDWARE PER BC 1008.1 (2014 CODE); 27-371; BC 1008.1.9 (2014 CODE); BC 1010.1.8 (2022 CODE); BC 1010.1.9 (2022 CODE). OBSERV
#39141476H
Mar 25, 2025
POP/IN-VIO
$0
Mar 13, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER: NO FIRE STOPPING PER BC 712.3 (2014 CODE); 27-345; BC 711.2.4 (2022 CODE. OBSERVED AC INSTALLED INTO WALL AT 1ST FLOOR AND BASEMENT AND HOLE PENETRATIONS T
#39141473M
Mar 25, 2025
POP/IN-VIO
$0
May 15, 2024Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #39074955H ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH COMMISSI
#39114411N
May 30, 2024
POP/IN-VIO
$0
May 15, 2024Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39074958N ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE TO FILE PERMI
#39114407K
May 30, 2024
POP/IN-VIO
$0
May 15, 2024Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 39074958P ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH COMMISSI
#39114410L
Jul 9, 2024
POP/IN-VIO
$0
Mar 27, 2024Construction CLASS - 2
OBSERVED IN THE BOILER ROOM LOCATED IN THE BASEMENT/CELLAR ACTIVE LEAK ON PIPING FROM TEMP BOILER. AS PER 102.3 OF THE PLUMBING CODE MAINTENANCE. INSTALLATIONS, BOTH EXISTING AND NEW, AND PARTS THEREOF SHALL BE
#39110101J
May 29, 2024
POP/IN-VIO
$0
Mar 27, 2024Construction CLASS - 2
OBSERVED IN THE BASEMENT/CELLAR JIM CAPS INSTALLED ON CAST IRON FITTINGS., REPAIR AND/OR REPLACE
#39110100H
May 29, 2024
POP/IN-VIO
$0
Dec 15, 2023Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#39074955H ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE
#39101586M
Jan 2, 2024
POP/IN-VIO
$0
Dec 15, 2023Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#39074958N ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILURE
#39101589H
Jan 2, 2024
POP/IN-VIO
$0
Dec 15, 2023Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION #39074959P ISSUED ON 11/30/2022 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. FAILUR
#39101596X
Jan 2, 2024
POP/IN-VIO
$0
Dec 2, 2022Boilers CLASS - 2
AS PER ONE AO SMITH DOMESTIC HOT WATER BOILER, YEAR BUILT 2014, SERIAL NO. 1433M001233. BOILER NOT REGISTERED. APPLY FOR PROPER PERMITS, CORRECT VIOLATING CONDITIONS, CALL FOR AN INSPECTION.
#39074976R
Dec 6, 2022
POP/IN-VIO
$0
Dec 2, 2022Elevators CLASS - 2
AS PER ONE NATURAL GAS BURNHAM BOILER, YEAR BUILT 2006. SERIAL NO. 64938167; BOILER NOT REGISTERED. APPLY FOR PROPER PERMITS, CORRECT VIOLATING CONDITIONS, CALL FOR AN INSPECTION.
#39074975P
Dec 6, 2022
POP/IN-VIO
$0
Dec 2, 2022Boilers CLASS - 2
AS PER ONE NATURAL GAS, BURNHAM CAST IRON BOILER, YEAR BUILT 2015, SERIAL NO. 65539938; BOILER NOT REGISTERED. APPLY FOR PROPER PERMITS, CORRECT VIOLATING CONDITIONS, CALL FOR AN INSPECTION.
#39074974N
Dec 6, 2022
POP/IN-VIO
$0
Nov 30, 2022Construction CLASS - 2
AT FIRST FLOOR, MECHANICAL ROOM, ACTIVE WATER FILTRATION FROM THE ROOF TO THE INTERIOR OF THE MECHANICAL ROOM., REPAIR AND/OR REPLACE
#39074960M
Dec 6, 2022
POP/IN-VIO
$0
Nov 30, 2022Construction CLASS - 1
OBSERVED: AT EXPOSURE # 3, BACK YARD, DISCHARD FIRE SCAPE IS BEING OBSTRUCTED BY MATERIALS STORED. ALSO, AT FIRST FL, EXIT TO BACKYARD, A DEFECTIVE WOODEN STAIRCASE WAS BUILT, BEING AN EMINENT RISK OF ACCIDENT
#39074955H
Dec 8, 2022
POP/IN-VIO
$0
Nov 30, 2022Construction CLASS - 2
OBSERVED: AT FIRST FLOOR, MECHANICAL ROOM, WOODEN STRUCTURE THAT SUPPORTS THE ROOF OF THE MECHANICAL ROOM, IS BEING PROVISIONALLY SUPPORTED BY DEFECTIVE WOODEN COLUMNS, WITHOUT PROPER ANCHORING AND INSTALLATION
#39074956J
Dec 6, 2022
POP/IN-VIO
$0
Nov 30, 2022Construction CLASS - 1
OBSERVED: AT FIRST FL, MECHANICAL ROOM, FLAMMABLE MATERIAL IS BEING STORED. ALSO, WOODEN STRUCTURE THAT SUPPORTS THE CEILING (COLUMNS) AND CEILING BEAMS HAVE NO FIRE PROTECTION, ROOM CONDITION WITH EASY PROPAGA
#39074959P
Dec 6, 2022
POP/IN-VIO
$0
Nov 30, 2022Construction CLASS - 1
OBSERVED: AT FIRST FLOOR, MECHANICAL ROOM, WOODEN STRUCTURE THAT SUPPORTS THE ROOF OF THE MECHANICAL ROOM, IS BEING PROVISIONALLY SUPPORTED BY DEFECTIVE WOODEN COLUMNS, WITHOUT PROPER ANCHORING AND INSTALLATION
#39074958N
Dec 6, 2022
POP/IN-VIO
$0
Nov 30, 2022Construction CLASS - 2
OBSERVED: AT CELLAR LEVEL, FIRE PROOF WALLS & CEILING SHOWS SEVERAL HOLES, OPENINGS DUE TO CEILING DAMAGE OR PIPE PENETRATION WITHOUT FIRE STOPPING PROVIDED. PREVIOUS VIOLATION # 39048680Z., PROVIDE/MAINTAIN FI
#39074957L
Dec 6, 2022
POP/IN-VIO
$0
Apr 7, 2022Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:OBSERVED:AT 1ST FL,MECHANICAL ROOM,EXPOSED WOOD CEILING W/O FIRE BARRIER,CEILING SUPPORTED BY DEFECTIVE WOODEN COLUMNS(CRACKS). ALSO,THE STRUCTURE(SHORING)
#35650620N
Jul 21, 2022
POP/IN-VIO
$0
Apr 7, 2022Construction CLASS - 2
OCCUPANCY CONTRARY TO THAT ALLOWED BY CERTIFICATE OF OCCUPANCY OR BUILDING DEPT RECORDS.OBSERVED CERTIFICATE OF OCCUPANCY #113386/1997 INDICATES AT CELLAR LEVEL BOILER ROOM FIRE PUMPRM GENERATOR PUMP ROOM & STO
#35650619X
Jul 21, 2022
POP/IN-VIO
$0
Oct 4, 2021Construction CLASS - 2
NOTED: OBSERVED AT FIRST FLOOR LEVEL (REAR) MECHANICAL ROOM, 6"X6" WOODEN VERTICAL POST THAT SUPPORTS THE CEILING IS SHIFTING OFF OF THE CEILING JOISTS, JOIST IS RESTING ON BEAM BY APPROXIMATELY 1 INCH., REPAIR
#39048679L
Oct 15, 2021
POP/IN-VIO
$0
Oct 4, 2021Construction CLASS - 2
NOTED: OBSERVED AT CELLAR'S, GENERATOR/FIRE PUMP ROOM, FIREPROOF CEILING TILES ARE MISSING AT VARIOUS LOCATIONS EXPOSING WOODEN JOISTS FROM FLOOR ABOVE., PROVIDE/MAINTAIN FIRE STOPPING
#39048680Z
Oct 15, 2021
POP/IN-VIO
$0
Sep 25, 2019Construction CLASS - 2
NOTE: OBSERVED AT FIRST FLOOR MECHANICAL ROOM, 6"X6" WOODEN SUPPORT MEMBERS THAT SUPPORT THE CEILING HAVE SHIFTED AND ARE BARELY ON THE HORIZONTAL BEAM. , REPAIR AND/OR REPLACE
#39010119J
Oct 4, 2019
POP/IN-VIO
$0
Sep 25, 2019Construction CLASS - 2
NOTED: OBSERVED AT FIRE PUMP/GENERATOR ROOM AT CELLAR, FIREPROOF CEILING TILES ARE MISSING THROUGHOUT ROOM AND EXPOSING WOODEN JOISTS AND SUB-FLOORING, ALSO ABOVE GAS METER. , PROVIDE/MAINTAIN FIRE STOPPING
#39010120R
Oct 4, 2019
POP/IN-VIO
$0
Sep 25, 2018Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED ON 9/25/18 AT ABOVE ADDRESS GAS LEAK ON DRESSER COUPLIN ON THE SERVICE SIDE OF THE BUILDING. CON-ED CALLED AND LOCKED THE VALVE. REMEDY:REPLACE AN
#35361829N
Nov 29, 2018
POP/IN-VIO
$0
Sep 25, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER:NO FIRE STOPPINGPER BC 712.3;27-345. NOTED:AT CELLAR, IN FIRE PUMP ROOM, DROP CEILING TILES MISSING AT CEILING ELIMINATING FIRE STOPPING. REMEDY:PROVIDE/MAI
#35361385L
Nov 29, 2018
POP/IN-VIO
$0
Sep 25, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT 1ST STORY IN MECHANICAL ROOM, WATER PENETRATING CEILING WITH AN ACTIVE FLOW. REMEDY: REPAIR AND/OR REPLACE
#35361383H
Nov 29, 2018
POP/IN-VIO
$0
Mar 8, 2018Construction CLASS - 2
WORK W/OUT A PERMIT.OBSERVED ON THE UPPERMOST FL IN THE STIRWELL WHERETHE INSP TEST(VALVE)IS INSTALLED A PRESSURE GUAGE HAS BEEN INSTALLED W/OUT A PERMI DOB RECORDS DO NOT SHOW ANY PERMITS/APPROVALS ISSUED FOR
#35322072Z
May 17, 2018
POP/IN-VIO
$0
Mar 8, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:OBSERVED AT FIRST FLOOR MECHANICAL ROOM,6INCH X 6INCH POSTS THAT ARE BEING USED TO SUPPORT AND ARRY THE LOAD OF THE SMALL ROOF AT THE REAR HAVE SHIFTE
#35317574M
May 31, 2018
POP/IN-VIO
$0
Mar 8, 2018Plumbing CLASS - 1
FAILURE TO HAVE NEW OR ALTERED PLUMBING SYSTEM TESTED.OBSERVED A PRESSURE GAUGE INSTALLED @THE UPPERMOST PART OF THE AUTOMATIC FIRE SPRINKLER SYSTEM HOWEVER DOB RECORDS DOES NOT SHOW ANY TEST BEING PERFORMED ON
#35322073K
May 17, 2018
POP/IN-VIO
$0
Mar 8, 2018Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NO FIRE STOPPINGPER BC 712.3;27-345.NOTED:OBSERVED AT CELLAR-WITHIN FIRE PUMP ROOM/GENERATOR ROOM PIPE/CONDUIT PENETRATIONS,SECTIONS OF ACOUSTICAL CEILING T
#35317573K
May 31, 2018
POP/IN-VIO
$0
Aug 31, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.OBSERVED @TOP OF STAIRWELL INSP TEST W/NO PRESSURE GAUGE INSTALLED AS IS REQUIRED.REM:REPAIR &/OR REPLACE. PHOTO TAKEN.
#35290311N
Dec 21, 2017
POP/IN-VIO
$0
Aug 31, 2017Construction CLASS - 2
FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER:NOTED.FIRE STOP MISSING IN THE FIRE PUMP ROOM THRU OUT ROOM HOLE IN WALL & CEILING,(GAS) & FUEL TANK ALSO IN ROOM.REM:PROVIDE/MAINTAIN FIRE STOPPING.
#35290653N
Dec 21, 2017
POP/IN-VIO
$0
Jul 19, 2016Construction CLASS - 2
FAILURE TO MAINTAIN BLDG CODE COMPLIANT: NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: @ CELLAR BOILER ROOM, APPROX 3' X 3' AREA OF METAL CEILING IS CORRODED/OPEN/MISING EXPOSING CONCEALED SPACE W/ WOOD JOISTS
#35200983Y
Sep 15, 2016
POP/IN-VIO
$0
Jun 17, 2016Construction CLASS - 1
WORK W/O PERMIT ON SANDPIPE TIME OF INSPECTION 1:15PM. AT TIME OF INSPECTION I OBSERVED DISCONNECTED AND CAPPED FIRE HOSE CONNECTION FOR FIRE DEPT USE ON EACH FLOOR FROM 1ST THROUGHOUT 5TH ON EXISTING STANDPIPE
#35181049Y
Sep 15, 2016
POP/IN-VIO
$0
DOB (1)
IssuedViolationStatus
Aug 21, 1991CONSTRUCTION

#A4BL01
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (0)

None open.

HPD (4) · C 0 · B 0 · A 4
IssuedClassViolationCorrect by
Nov 27, 2017A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACOUSTIC CEILING , 2nd STORYMar 2, 2018
Nov 27, 2017A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACOUSTIC CEILING ENTIRE STORY , 5th STORYMar 2, 2018
Nov 27, 2017A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACOUSTIC CEILING , 1st STORYMar 2, 2018
Nov 8, 2017AApt 501 · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION ACOUSTIC CEILING ENTIRE STORY LOCATED AT DORMITORY 501, 5th STORYFeb 11, 2018

Check the agency records