7 floors · 98 apartments · 77,028 sq ft · built 2015 · class RM · owner of record: Unavailable Owner
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 70 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 86 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 77,028 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 314 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 801 days | Next cycle year 2028 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2494). Agency page | Dec 31, 2034 in 2992 days | Next due 2034 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-16 (Accepted). Agency page | On file | 2026 reports accepted |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page | On file | Cycle 10 filing on record: SAFE (2026-09-08) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 6, 2026 | Elevators CLASS - 2 MISALINGED CAB MIRROR (BC 3001.2). REPLACE WORN GIBS WHERE NEEDED. (2.11.11.5.7.). REMOVE OBSTRUCTION FROM GOVERNOR ACCESS DOOR (2.7.6.3.4.). PROVIDE READILY AVAILABLE KEYS TO MACHINE ROOM (2.7.3.1.1.). #39199528M | Oct 21, 2026 PENDING | $1,562 |
| Aug 6, 2026 | Elevators CLASS - 2 MISALINGED CAB MIRROR (BC 3001.2). REPLACE WORN GIBS WHERE NEEDED. (2.11.11.5.7.). REMOVE OBSTRUCTION FROM GOVERNOR ACCESS DOOR (2.7.6.3.4.). #39199527K | Oct 21, 2026 PENDING | $1,562 |
| Jan 23, 2026 | Elevators CLASS - 2 SHORTEN HOIST ROPES. MISALINGED CAB MIRROR. REPALCE WORN GIBS WHERE NEEDED. LABEL, AND PROVIDE UNOBSTRUCTED ACCESS , GOVERNOR ACCESS DOOR. CWT SCRAPING DURING TRAVEL. #39174865M | Oct 13, 2026 IN VIOLATION | $625 |
| Jan 23, 2026 | Elevators CLASS - 2 SHORTEN HOIST ROPES. MISALINGED CAB MIRROR. REPALCE WORN GIBS WHERE NEEDED. LABEL, AND PROVIDE UNOBSTRUCTED ACCESS , GOVERNOR ACCESS DOOR. #39174864K | Oct 13, 2026 IN VIOLATION | $625 |
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 23, 2026 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER LOCK INSTALLED AT BUILDING ENTRANCE DOOR | Sep 29, 2026 |
| Aug 31, 2026 | A | Apt 6F · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING THOUGHTOUT IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH | Dec 4, 2026 |
| Jul 16, 2026 | A | Apt 2A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 19, 2026 |
| Jul 14, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM, 1st STORY | Jul 20, 2026 |
| Jul 14, 2026 | C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM, 1st STORY | Jul 20, 2026 |
| Jun 11, 2026 | B | Apt 2A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jul 16, 2026 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 23, 2026 | HPD C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER LOCK INSTALLED AT BUILDING ENTRANCE DOOR | Open |
| Aug 31, 2026 | HPD A | § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING THOUGHTOUT IN THE ENTIRE APARTMENT LOCATED AT APT 6F, 6th STORY, 3rd APARTMENT FROM WEST AT NORTH | Open |
| Aug 6, 2026 | ECB | Elevators: MISALINGED CAB MIRROR (BC 3001.2). REPLACE WORN GIBS WHERE NEEDED. (2.11.11.5.7.). REMOVE OBSTRUCTION FROM GOVERNOR ACCESS DOOR (2.7.6.3.4.). PROVIDE READILY AVAILABLE KEYS TO MACHINE ROOM (2.7.3.1.1.). | Open |
| Aug 6, 2026 | ECB | Elevators: MISALINGED CAB MIRROR (BC 3001.2). REPLACE WORN GIBS WHERE NEEDED. (2.11.11.5.7.). REMOVE OBSTRUCTION FROM GOVERNOR ACCESS DOOR (2.7.6.3.4.). | Open |
| Jul 16, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM SOUTH AT WEST | Open |
| Jul 14, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 6K, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTH | Closed |
| Jul 14, 2026 | HPD C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM, 1st STORY | Open |
| Jul 14, 2026 | HPD C | § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3B, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Closed |
| Jul 14, 2026 | HPD C | § 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM LOCKED DOOR AT BOILER ROOM, 1st STORY | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)