9 floors · 146,042 sq ft · built 1996 · class I6 · owner of record: Union Plaza Snf Realty Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 146,042 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 182 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 182 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1157 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2031) Likely applies Local Law 87 · Calendar year 2031 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 4981). Agency page | Dec 31, 2031 in 1887 days | Next due 2031 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-09 (Accepted). Agency page | On file | 2026 reports accepted |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $3,067,600 in late-filing or failure-to-file penalties. Agency page | On file | Cycle 10 filing on record: UNSAFE (2026-05-11) |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 20, 2026 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7C AND 8C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #812370. AGG1: PRIOR NOV 37026134L UNDER #37036644K | Jul 28, 2026 DEFAULT | $5,000 |
| Apr 8, 2025 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9C REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL #912370. REMEDY: SUBMIT ACCEPTABLE REQU #37034848N | Apr 7, 2026 IN VIOLATION | $2,500 |
| Jan 9, 2025 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. NOTE: OBSERVED AT EXPOSURE 1 WEST ELEVATION SEVERAL LOCATIONS OF DAMAGED/CRACKED COPING STONESAND MASONRY CRACKS AT ARCHES NEAR FRONT ENTRANCE. AT #35689323P | Mar 18, 2025 DEFAULT | $6,250 |
| Jan 16, 2024 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7C & 8C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #812370.AGG1:PRIOR NOV 37022345N UNDER 28- #37026134L | May 7, 2024 IN VIOLATION | $0 |
| Jul 31, 2023 | Construction CLASS - 1 SUPPORTED SCAFFOLD JOB#Q00147500 EQ-103.00 DETAIL'D TO ERECT@FRONT/EXP#1 ONLY.@9STORY ALT2 FACADE SITE OBSERVE SUPPORTED SCAFFOLD ERECTED@REAR/EXP#3 OF BUILDING UP TO ROOF LEVEL NOT TO PLAN WITH PLATFORMS THROU #39519976X | Oct 10, 2023 IN VIOLATION | $0 |
| Oct 8, 2021 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7C AND 8C REPORT INDICATING CORRECTIONOF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#812370.REMEDY:FILE ACCEPTABLE REPORT. #37022345N | Mar 29, 2022 IN VIOLATION | $0 |
| Nov 8, 2018 | Construction CLASS - 1 FAILURE TO TAKE PROVIDE SAFETY MEASURES, SUCH AS SIDEWALK SHEDS, FENCEETEC WHERE REQUIRED TO PROTECT AND SECURE PUBLIC SAFETY FROM DOCUMENTED UNSAFE FACADE AS PER 1RCNY 103-04. FACADE TECHNICAL REPORT FILE UNSA #35365183L | Feb 19, 2019 IN VIOLATION | $0 |
| Mar 12, 2018 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXT WALLS OR APPURTENANCES REQD BY 28-302.4.FOR CONTROL#712370.AGG2 HISTORY OF NONCOMPLIANCE ON 36024034Z,36027258L #37009404H | Jul 10, 2018 IN VIOLATION | $0 |
| Dec 30, 2015 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS: PERIODIC INSPECTION PF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28.302 & THE DOB'S RULES & REGULATIONS. REMEDY: FILE #36024034Z | Jun 3, 2016 IN VIOLATION | $0 |
| Jan 26, 2015 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28-302 & THE DEPT OF BLDGS RULES & REGULAT #36027258L | Jul 14, 2015 ADMIT/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| May 2, 2025 | CONSTRUCTION FTM BLDG IN A CODE COMPLIANT MANNER. NOTE: AT THE TIME OF INSPEC OBSERVED AT EXP 1 CRACK GRASS AWNING AT MULTIPLE LOCATIONS OBSERVED SPALLING CRACK STONE AT WATER TABLE. AT EXP #3 OBSERVED CRACK GLASS AT GREEN ROOM. REMEDY: REPAIR AND OR REPLACE #SR40703DO | DOB VIOLATION - ACTIVE |
| May 2, 2025 | CONSTRUCTION EMERGENCY WORK ORDER DUE TO SHATTERED/CRACKED GLASS ON AWNING AT EXPOSURE #1 WEST ELEVATION ABOVE THE "NEW HOPE DAY CENTER" ENTRANCE REMEDY: IMMEDIATELY REMOVE/REPLACE SHATTERED GLASS PANE UNDER SUPERVISION OF A LICENSED PROFESSIONAL #SR40708DO | DOB VIOLATION - ACTIVE |
| Nov 8, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. DAMAGED WATER TABLE/CORNICE IN MULT LOCS OF EXPOSURE #2 @ EXPOSURE #1 CRACK GLASS AWNING AT GROUND LEVEL. AT ROOF BULKHEAD OBSERVED MULTIPLE STEP CRACKS ON BULKHEAD. CRACKED WINDOWN IN SUN ROOM @ ROOF. MISSING/DAMAGED MOTAR JOINTS THROUGHOUT F #SR40701DO | DOB VIOLATION - ACTIVE |
| Jun 26, 2024 | CONSTRUCTION FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.OBSERVED DAMAG ED/MISSING MORTAR JOINTS ON EXP1,2,AND 3 WEST,NORTH,AND EAST ELEV.ALSO OBSERVED SPALLED MASONRY ON 8TH FLOOR TERRACE AT EXP1 WEST ELEV.REMEDY FIX AND/OR REPLACE #SR40701YK | DOB VIOLATION - ACTIVE |
| Feb 22, 2024 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 #00918 | DOB VIOLATION - ACTIVE |
| Oct 30, 2018 | FACADE SAFETY PROGRAM #HAZ87655 | DOB VIOLATION - ACTIVE |
| Oct 30, 2018 | FACADE SAFETY PROGRAM #HAZ77654 | DOB VIOLATION - ACTIVE |
| Dec 31, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013 #01341 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 29, 2026 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Oct 2, 2026 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2025 Cat1 Test Report | Active |
| Sep 25, 2026 | Benchmarking - LL84 DQ-EN-BENCH FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Active |
| Feb 22, 2024 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2018 Cat1 Test Affirmation of Correction | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Report | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2019 Cat1 Test Report | Active |
| Oct 30, 2018 | Facades FISP CYCLE 8C UNSAFE REPORT FILED | Active |
| Oct 30, 2018 | Facades FISP CYCLE 7C UNSAFE REPORT FILED | Active |
| Dec 31, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013 | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 29, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Affirmation of Correction | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Cat1 Test Report | Open |
| Sep 25, 2026 | DOB Safety | Benchmarking - LL84: FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)