5 floors · 28 apartments · 22,500 sq ft · built 1930 · class C1 · owner of record: 308 Hull Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 66 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 66 days | Annual |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-09 (Payment Verification In Progress). Agency page | Dec 31, 2026 in 66 days | 1 of 1 without an accepted 2026 report yet |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 82 days | Annual |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1162 days | Next cycle year 2029 |
None open.
None open.
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 7, 2026 | C | Apt WIN · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE FOYER LOCATED AT BSMT-APT WIN, 2nd BSMT-APT FROM WEST AT NORTH | Oct 13, 2026 |
| Jun 27, 2025 | A | Apt 32 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT EAST, WEST, AND SOUTH WALLS IN THE 3rd ROOM FROM NORTH LOCATED AT APT 32, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH | Sep 30, 2025 |
| Oct 28, 2024 | A | Apt 2 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT EAST WALL IN THE KITCHEN LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Jan 31, 2025 |
| Oct 28, 2024 | C | Apt 2 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 23, 2024 |
| Sep 13, 2024 | C | Apt WIS · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT WIS, 1st APARTMENT FROM SOUTH AT WEST | Oct 9, 2024 |
| Sep 6, 2024 | A | Apt 2 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING , WALLS ,TRIMS , BASEBOARDS, MOLDINGS THROUGHOUT IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Dec 10, 2024 |
| Aug 29, 2024 | A | Apt 2 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Dec 2, 2024 |
| Aug 23, 2024 | A | Apt 2 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING, WEST, EAST, SOUTH AND NORTH WALLS IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Nov 26, 2024 |
| Jul 8, 2024 | B | Apt WI1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT BSMT-APT WI1, 1st BSMT-APT FROM NORTH AT EAST | Aug 12, 2024 |
| Jul 8, 2024 | A | Apt 2 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING, WALLS, DOORS AND TRIMS IN THE ENTIRE APARTMENT LOCATED AT APT 2, 1st STORY, 2nd APARTMENT FROM WEST AT NORTH | Oct 11, 2024 |
| Apr 29, 2024 | C | Apt WIS · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND ALL WALLS IN THE FOYER LOCATED AT BSMT-APT WIS, 1st BSMT-APT FROM SOUTH AT WEST | May 5, 2024 |
| Apr 29, 2024 | C | Apt WIS · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH LOCATED AT BSMT-APT WIS, 1st BSMT-APT FROM SOUTH AT WEST | May 5, 2024 |
| Apr 29, 2024 | C | Apt WIS · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE FOYER LOCATED AT BSMT-APT WIS, 1st BSMT-APT FROM SOUTH AT WEST | May 5, 2024 |
| Apr 7, 2023 | B | Apt 42 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC TILES AT FLOOR. IN THE KITCHEN LOCATED AT APT 42, 4th STORY, 2nd APARTMENT FROM WEST AT NORTH | May 12, 2023 |
| Jul 27, 2022 | C | Apt 32 · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1; WG TO REPLACE = 0; WG TO REPAIR = 0; IN THE ENTIRE APARTMENT LOCATED AT APT 32, 6th STORY, 2nd APA | Aug 22, 2022 |
| Sep 14, 2016 | B | Apt 3 · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 3, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Oct 19, 2016 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 7, 2026 | HPD C | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE FOYER LOCATED AT BSMT-APT WIN, 2nd BSMT-APT FROM WEST AT NORTH | Open |
| Jul 16, 2026 | HPD B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AND ASSEMBLY AT DOOR FROM VESTIBULE TO PUBLIC HALL , 1st STORY | Closed |
| Jul 16, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE LATCH AT DOOR FROM VESTIBULE TO PUBLIC HALL , 1st STORY | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 26, 2026, 2:19 PM ET. BBL 2033470038.