3 floors · 3 apartments · 1,680 sq ft · built 1920 · class C0 · owner of record: Pavel, Mendel
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 46 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 46 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 62 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 290 days | Registered through 2027-09-01 |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 777 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Oct 3, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH DEPARTMENT OF BUILDING FOR SUMMONS 39089271Z., FILE A CERTIFICATE OF CORRECTION #39162401X | Dec 10, 2025 DEFAULT | $6,250 |
| Oct 3, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH DEPARTMENT OF BUILDING FOR SUMMONS 37025511N., FILE A CERTIFICATE OF CORRECTION #39162400Y | Dec 10, 2025 DEFAULT | $6,250 |
| Aug 26, 2025 | Unknown CLASS - 1 ATOI OBSERVED THREE SPLIT AC UNIT CONDENSER WITH 3 DISCONNECT BOXES SUPPLYING POWER AT EXPOSURE #1. NO PERMIT ON FILE WITH THE DEPARTMENT FOR ELECTRICAL WORK., OBTAIN PERMIT #39158469K | Nov 5, 2025 ADMIT/IN-VIO | $0 |
| Aug 2, 2024 | Unknown CLASS - 2 AT THE TIME OF INSPECTION 3-STORY OCCUPIED MULTI-FAMILY BUILDING NO ACCESS NO CONSTRUCTION ACTIVITIES OBSERVED SIDEWALK SHED INSTALLED FOR FACADE REPAIR AT EXPOSURE 1 WORK PERMIT B00898635-I1-SH EXPIRED 07/05/2 #39531015Z | Nov 13, 2024 IN VIOLATION | $1,250 |
| Mar 27, 2024 | Construction CLASS - 2 ATOI OBSERVED ONGOING PLUMING WORK BEING DONE ON THE 2ND AND 3RD FLOOR APARTMENTS, OBSERVED BATHTUBS, TOILETS AND SINKS REMOVED AND WALLS OPEN AND NEW COPPER PIPES BEING INSTALLED, OBSERVED COPPER PIPES WITH NE #39110122Z | Nov 25, 2024 IN VIOLATION | $1,250 |
| Mar 27, 2024 | Construction CLASS - 1 ATOI OBSERVED C-HOOKS BEING USED AT EXPOSURE 2 WITH ROPE CONNECTED TO A PLATFORM FOR ONGOING WORK BEING DONE AT EXPOSURE 2 FACADE. OBSERVED C-HOOK INSTALLED INCORRECTLY USING CINDER BLOCKS AND WOOD SHIMS CAUSIN #39110124M | Nov 25, 2024 IN VIOLATION | $2,500 |
| Mar 27, 2024 | Cranes and Derricks CLASS - 2 ATOI OBSERVED C-HOOKS BEING USED AT EXPOSURE 2 WITH ROPE CONNECTED TO A PLATFORM FOR ONGOING WORK BEING DONE AT EXPOSURE 2 FACADE. NO SUSPENDED SCAFFOLDING NOTIFICATION IN DOB SYSTEM. FAILURE TO NOTIFY DEPARTME #39110123K | Nov 25, 2024 IN VIOLATION | $2,500 |
| Mar 27, 2024 | Unknown CLASS - 1 ATOI OBSERVED ON GOING CONSTRUCTION IN BUILDING WITH EXCESSIVE AMOUNT OF DUST AND DEBRIS THROUGH OUT PUBLIC HALLWAY AND ENTRANCE OF BUILDING, ONE TENANT LIVING IN APARTMENT 1, NO TPP ON FILE WITH DEPARTMENT, FI #39110125Y | Nov 25, 2024 IN VIOLATION | $10,000 |
| Oct 11, 2023 | Construction CLASS - 1 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION 062723C0102AA DATED 6/27/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCRALLY DEFICIENT CONDITIONS. AS OF 10/11/202 #37025511N | Aug 19, 2025 IN VIOLATION | $1,250 |
| Jun 27, 2023 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES; NOTED; OBSERVED: OBSERVED LEFT SIDE FRONT & REAR EXTERIOR FACADE WALL IS CRACKED WITH SEPARATION. THIS IS A POTENTIAL FALL HAZARD TO THE PUBLIC., MAINTAIN #39089271Z | Sep 6, 2023 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Jun 27, 2023 | CONSTRUCTION OWNER TO UBMIT REPORT TO BOROUGH ENFORCEMENT W/IN 30 DAYS ADDRESSING A LL CONDITIONS W/PLANS, PHOTOS, RECOMMENDING TIME FRAME AND REPAIRS TO BE COMPLETED #0102AA | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Aug 28, 2024 | B | Apt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT EAST WALL (APPROX. 1 SQ. FT.) IN THE FOYER LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 16928130 ISSUED 26-APR-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017. | Oct 2, 2024 |
| Apr 30, 2024 | C | Apt 1 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | May 26, 2024 |
| Apr 30, 2024 | B | Apt 1 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 4, 2024 |
| Apr 30, 2024 | A | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 3, 2024 |
| Apr 30, 2024 | B | Apt 1 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 4, 2024 |
| Apr 30, 2024 | B | Apt 1 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND ALL WALLS (APPROX. 23 SQ. FT.) IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 4, 2024 |
| Apr 30, 2024 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING AT PUBLIC HALL, 1st STORY | Aug 3, 2024 |
| Apr 30, 2024 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING AT PUBLIC HALL, 1st STORY | May 6, 2024 |
| Apr 30, 2024 | A | Apt 1 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILES AT WEST WALL (NEAR WASH BASIN) IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 3, 2024 |
| Apr 30, 2024 | A | Apt 1 · § 27-2005 ADM CODE PAINT METAL IN ACCORDANCE WITH DEPT. REGULATION THE STEAM RISER AT NORTH WALL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 3, 2024 |
| Apr 30, 2024 | A | Apt 1 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT CEILING ABOVE STEAM RISER AT NORTH WALL IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 3, 2024 |
| Apr 30, 2024 | A | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 3, 2024 |
| Apr 30, 2024 | A | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING, EAST. AND WEST WALLS IN THE KITCHEN LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Aug 3, 2024 |
| Apr 30, 2024 | C | Apt 1 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ... (HINGES) IN THE ENTRANCE LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | May 14, 2024 |
| May 23, 2019 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING , 1st STORY | Aug 26, 2019 |
| May 23, 2019 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING , 1st STORY | Aug 26, 2019 |
| May 23, 2019 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING., 1st STORY | Aug 26, 2019 |
| May 23, 2019 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. , 1st STORY | Aug 26, 2019 |
| May 23, 2019 | C | § 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT BUILDING FRONT | May 31, 2019 |
| May 23, 2019 | B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF TREE BRANCHES FROM FIRE ESCAPE, BUILDING FRONT FROM SOUTH | Jun 27, 2019 |
| May 23, 2019 | B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR FIRE RETARDANT PLASTER AT WEST WALL IN PUBLIC HALL , 1st STORY | Jun 27, 2019 |
| May 23, 2019 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING , 1st STORY | May 31, 2019 |
| May 23, 2019 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS , 2ND STORY BALCONY AT BUILDING FRONT FROM SOUTH | Jun 27, 2019 |
| May 23, 2019 | B | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR FIRE RETARDANT PLASTER AT WEST WALL IN VESTIBULE , 1st STORY | Jun 27, 2019 |
| May 23, 2019 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN FLOOR AND VINYL COVER AT PUBLIC HALL , 1st STORY | Jun 27, 2019 |
| May 23, 2019 | B | § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. | Jun 27, 2019 |
| May 22, 2019 | B | Apt 1 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 26, 2019 |
| May 22, 2019 | B | Apt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH | Jun 26, 2019 |
| Dec 22, 2014 | C | SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT 1ST STORY PUBLIC HALL AND ON DOOR TO BOILER ROOM,BASEMENT | Dec 30, 2014 |
| Dec 22, 2014 | C | SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM ,DOOR LOCKED AT PUBLIC HALL, 1st STORY | Dec 30, 2014 |
| Dec 22, 2014 | B | SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS ,FIRE ESCAPE,FRONT OF BUILDING | Jan 26, 2015 |
| Dec 22, 2014 | B | SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. REPLACE WITH 2 X 1/2 INCH IRON BAR EXTENDING ACROSS AND SECURED TO 2 BRACKETS, THE BROKEN OR DEFECTIVE ANGLE IRON OR BAR AT FOOT OF GOOSENECK LADDER ,FIRE ESCAPE,FRONT OF BUILDING | Jan 26, 2015 |
| Mar 20, 2014 | C | SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING SIGN AT PUBLIC HALL, 1st STORY | Mar 28, 2014 |
| Mar 7, 2014 | B | SECTION 27-2005 ADM CODE FIRE ESCAPE DEFECTIVE. ADJUST THE DROPLADDER SO THAT IT WILL SLIDE EASILY IN THE GUIDE RODS AT FRONT OF BUILDING AT FIRE ESCAPE | Apr 11, 2014 |
| Jun 7, 2013 | B | SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS MINIMUM WATTS REQUIRED , LIGHT FIXTURE PRESENT | Jul 12, 2013 |
| Jul 5, 2012 | B | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT MATRIAL AT WEST WALL AT PUBLIC HALL | Aug 9, 2012 |
| Jan 4, 2008 | A | SECTION 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT WALLS AND CEILING AT PUBLIC HALL, 1st STORY | Apr 8, 2008 |
| Jan 4, 2008 | C | SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WEST WALL AT PUBLIC HALL, 1st STORY | Jan 10, 2008 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 15, 2026, 1:30 PM ET. BBL 3024370040.