Bronx · Block 3343 · Lot 49 · 10467

3280 Reservoir Oval East

5 floors · 30 apartments · 24,360 sq ft · built 1929 · class C1 · owner of record: Mujo Muratovic Llc

22open violations
$31,250ECB/OATH penalties owed
3HPD class C (immediately hazardous)
45dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 45 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-03-24 (Accepted). Agency page

Dec 31, 2026
in 45 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 61 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 289 days
Registered through 2027-09-01
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1141 days
Next cycle year 2029

Open violations

ECB / OATH (2) · $31,250 owed
IssuedViolationHearingBalance
Dec 8, 2025Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER: CONTROL #347955 VIO #102425PI20705TC, DATED 10/24/25. NO COMPLIANCE OF FILE FOR CORRECTIVE ACTIVE ACTION PLAN. REMEDY: COMPLY WITH THE COMMISSIONER'S ORDER.
#35718992M
Mar 11, 2027
DEFAULT
$25,000
Aug 21, 2025Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. I OBSERVED BUILDING EXTERIOR WALLS IN DISREPAIR AT VARIOUS LOCATIONS. AT EXPOSURE 01-FRONTSIDE-LEANING PARAPET WALL-RIGHTSIDE TOWARDS THE ROOFDECK, OUTSIDE
#35719029Z
Mar 12, 2027
DEFAULT
$6,250
DOB (2)
IssuedViolationStatus
Oct 24, 2025CONSTRUCTION
FTM W/COMMISSIONER'S ORDER CONTROL#348168 VIO#082125PI20701HZ DATED 8/21/25 REQUIRING OWNER TO PROVIDE A CORRECTIVE ACTION PLAN BY 9/12/25 &START BLDG REPAIRS UNDER PERMIT BY 10/21/25&COMPLETED/SIGNED OFF BY 11/21/25 AS OF 10/24/25 A CAP&EVIDENCE OF REPR WORK WAS NOT REC'D IMMED COMPLY W/COMMISSIONE
#PI20705TC
DOB VIOLATION - ACTIVE
Aug 21, 2025CONSTRUCTION
CORRECTIVE ACTION PLAN REQ'D-OBSVD EXTERIOR WALLS IN DISREPAIR AT VARIOUS LOCATIONS. FRONT SIDE PARAPET WALL & CORNER IS LEANING INWARD, SIDE WALL CRACKED& SEPARATING. OWNER TO IMMED RETAIN NYSRA IN GOOD STANDING W/NYS-ED TO EVAL THE ENTIRE BLDG & SUBMIT A CORRECTIVE ACTION PLAN BY 9/21/25 BLDG TO B
#PI20701HZ
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Dec 15, 2025Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2024 External Inspection Affirmation of Correction for LP Device
Active
Sep 18, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle B (premises is in Community District 7)
Active
HPD (16) · C 3 · B 4 · A 9
IssuedClassViolationCorrect by
Dec 1, 2025B§ 27-2005 ADM CODE PROVIDE GLASS PANES AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORYJan 5, 2026
Dec 1, 2025B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF PLEXIGLASS AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORYJan 5, 2026
Dec 1, 2025B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOCK AND LATCH SET AT BUILDING VESTIBULE DOOR AT PUBLIC HALL, 1st STORYJan 5, 2026
Apr 22, 2022C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT PUBLIC HALL, 1st STORYApr 28, 2022
Apr 22, 2022A§ 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT PUBLIC HALL, 1st STORYJul 26, 2022
Apr 22, 2022A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.Jul 26, 2022
Apr 22, 2022A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYJul 26, 2022
Apr 22, 2022A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYJul 26, 2022
Apr 22, 2022A§ 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT BUILDING FRONT NORTH EAST STACK AT FIRE ESCAPEJul 26, 2022
Apr 5, 2021C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM NEAR MAILBOXES , 1st STORYApr 11, 2021
Apr 5, 2021C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOMApr 11, 2021
Nov 13, 2019A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD.Feb 16, 2020
Nov 13, 2019A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTEDFeb 16, 2020
Oct 21, 2013BApt D3 · SECTION 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE CEILING IN THE KITCHEN LOCATED AT APT D3, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTNov 25, 2013
Oct 21, 2013ASECTION 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT THE EAST FIRE ESCAPE, FRONT OF THE BUILDINGJan 24, 2014
Oct 21, 2013AApt D3 · SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE NORTH WALL IN THE KITCHEN LOCATED AT APT D3, 4th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 24, 2014

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 5:41 AM ET. BBL 2033430049.