Manhattan · Block 1986 · Lot 1 · 10027

3260 Broadway

1 floors · 1,950 sq ft · built 1966 · class G4 · owner of record: The Trustees Of Columbia University

6open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
70dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 70 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 70 days
Keep the report on file (not filed with DOB)

Open violations

ECB / OATH (0)

None open.

DOB (6)
IssuedViolationStatus
May 24, 2018CONSTRUCTION
FTM BLDG IN SAFE COND.1 STRY AUTO SERVICE STATION @SE CORNER OF CORNER LOT OF MASONRY WALLS W/STEEL&WOOD FRAMED ROOF.INT LOAD BEAR CMU WALL IMPACT BY VEHICLE&PART COLL.ROOF RESUPPORTED BY TEMP SHOR PERSUANT TO COMM ORDER#050218FEU10901IK.REMEDY:FILE PLANS&OBT PERM TO RPR DAMAGED PARTS OF BLDG BY 6/3
#FEU10901IK
DOB VIOLATION - ACTIVE
May 24, 2018CONSTRUCTION
FAILURE TO COMPLY W/COMMISSIONERS ORDER #050218FEU10901IK ISSUED ON 5/2/18 FOR THE IMMED SHORING OF PART OF THE BLDG.AS OF DATE OF THIS VIOLATION APPLICATION FOR SHORING HAS NOT BEEN SUBMITTED TO THE DEPT REMEDY:COMPLY W/COMMISSIONERS ORDER #050218FEU10901IK IMMED
#FEU10902IK
DOB VIOLATION - ACTIVE
May 2, 2018CONSTRUCTION
EMERG WRK.1 STRY AUTO SERVICE BLDG @SE CORNER OF LOT OF MASONRY WALLS STEEL/WOOD FRAMED ROOF.INT LOAD BEAR CMU WALL IMPACT BY VEHICLE&PART COLL.REMAIN PORT OF WALL&PORT OF ROOF ABOVE @RISK OF COLL.REMEDY:IMMED SHORE PORT OF ROOF @RISK OF COLL.REMOVE ALL FALL/COLL HAZARDS.WRK TO BEG NO LATER 5/3/18.P
#FEU10901IK
DOB VIOLATION - ACTIVE
Apr 28, 2018CONSTRUCTION
DUE TO VEHICLE STRIKING THE EXPOSURE # 3 REAR WALL DISPALCING SECTION OF BEARING WALL FOR COLUMN & ROOF JOIST
#CNE01RWS
DOB VIOLATION - ACTIVE
Jan 18, 2012CONSTRUCTION

#CN10901MD
DOB VIOLATION - ACTIVE
May 13, 1976ELECTRIC SIGNS

#D32
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 22, 2026, 6:35 PM ET. BBL 1019860001.