6 floors · 74 apartments · 60,000 sq ft · built 1939 · class D1 · owner of record: Parkash 3250 Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 60,000 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 309 days | Registered through 2027-09-01 |
| Energy audit and retro-commissioning (2027) Likely applies Local Law 87 · Calendar year 2027 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 3347). Agency page | Dec 31, 2027 in 430 days | Next due 2027 |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1161 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-08 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 17, 2026 | Elevators CLASS - 2 : FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE. #39204531R | Dec 4, 2026 PENDING | $625 |
| Jul 22, 2026 | Construction CLASS - 2 AT TIME OF INSPECTION, OCCUPIED 6-STORY BUILDING OBSERVED WITH SIDEWALK SHED LIGHTING NOT PROPERLY MAINTAINED. ONLY MINIMAL LIGHTING WAS PROVIDED BENEATH THE SHED, LEAVING PORTIONS OF THE PEDESTRIAN WALKWAY INA #39556900M | Apr 15, 2027 PENDING | $2,400 |
| Jul 22, 2026 | Unknown CLASS - 2 AT TIME OF INSPECTION, OCCUPIED 6-STORY BUILDING OBSERVED WITH SIDEWALK SHED PERMIT #X01211409 EXPIRED ON 06/06/2026. SIDEWALK SHED IN PLACE WITHOUT A VALID PERMIT. FAILURE TO MAINTAIN A VALID PERMIT FOR PEDEST #39556901Y | Apr 15, 2027 PENDING | $1,250 |
| May 1, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED VIOLATING CONDITIONS HAVE BEEN CORRECTED. NO CERTIFICATE OF #39186893H | Feb 5, 2027 PENDING | $1,250 |
| May 1, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED VIOLATING CONDITIONS HAVE BEEN CORRECTED. NO CERTIFICATE OF #39186895L | Jan 29, 2027 PENDING | $1,250 |
| May 1, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED VIOLATING CONDITIONS HAVE BEEN CORRECTED. NO CERTIFICATE OF #39186888N | Feb 5, 2027 PENDING | $1,250 |
| May 1, 2026 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. AT TIME OF INSPECTION, NO PERMIT AND NO CERTIFICATE OF CORRECTION FILE WITH THE DEPARTMENT OF BUILDINGS. FAILURE TO COMPLY WITH AND CERTIFY CORRECTION #39186890M | Feb 5, 2027 PENDING | $2,500 |
| May 1, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED VIOLATING CONDITIONS HAVE BEEN CORRECTED. NO CERTIFICATE OF #39186891Y | Feb 5, 2027 PENDING | $1,250 |
| May 1, 2026 | Construction CLASS - 1 UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. AT TIME OF INSPECTION, NO PERMIT AND NO CERTIFICATE OF CORRECTION FILE WITH THE DEPARTMENT OF BUILDINGS. FAILURE TO COMPLY WITH AND CERTIFY CORRECTION #39186892X | Feb 5, 2027 PENDING | $2,500 |
| May 1, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED VIOLATING CONDITIONS HAVE BEEN CORRECTED. NO CERTIFICATE OF #39186894J | Jan 29, 2027 PENDING | $1,250 |
| May 1, 2026 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS. AT TIME OF INSPECTION, OBSERVED VIOLATING CONDITIONS HAVE BEEN CORRECTED. NO CERTIFICATE OF #39186896N | Jan 29, 2027 PENDING | $1,250 |
| May 1, 2026 | Construction CLASS - 1 FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT TIME OF INSPECTION, OBSERVED STEP CRACKING, MISSING AND SPALLING MORTAR JOINTS, AND MISSING/DISLODGED BRICKS AT MULTIPLE LOCATIONS ALONG EXPOSURE #1 ( #39186889P | Feb 5, 2027 PENDING | $6,250 |
| Jan 7, 2026 | Elevators CLASS - 2 CLASS 2 RTS: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE. #39172885K | Mar 20, 2026 IN VIOLATION | $312 |
| Aug 13, 2025 | Elevators CLASS - 2 CLASS 2 RTS:FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION,DEVICE IS FOUND TO BE OUT OF SERVICE.RESTORE DEVICE TO SERVICE.RESPONDENT #39156950H | Sep 28, 2026 IN VIOLATION | $3,125 |
| Jul 31, 2025 | Construction CLASS - 1 CELLAR LEVEL IN ALL ROOM FIRESTOP NOT DONE, FOAM USED IN SOME ROOMS AND HOLES LEFT OPEN. NO AREAS ARE DONE TO CODE AREA'S NEED TO BE FULLY FIRE STOPPED., PROVIDE/MAINTAIN FIRE STOPPING #39155660P | Sep 14, 2026 IN VIOLATION | $12,500 |
| Jul 31, 2025 | Quality of Life CLASS - 1 ROOM3 END OF HALLWAY OUTSIDE OF LAUNDRY ROOM A ONE BEDROOM APT MADE WITH A FULL 3PC BATHROOM., RESTORE TO PRIOR LEGAL CONDITION #39155663K | Sep 14, 2026 IN VIOLATION | $15,000 |
| Jul 31, 2025 | Quality of Life CLASS - 1 ROOM1 GAS METER INFRONT OF SUPER APT MADE INTO A BEDROOM, WITH SINK AND SHOWER INSTALLED., RESTORE TO PRIOR LEGAL CONDITION #39155661R | Sep 14, 2026 IN VIOLATION | $25,000 |
| Jul 31, 2025 | Quality of Life CLASS - 1 ROOM4 STORAGE/WORKSHOP ROOM FAR CORNER OF BUILDING TURNED INTO APT WITH SINK AND 3PC BATHROOM., RESTORE TO PRIOR LEGAL CONDITION #39155664M | Sep 14, 2026 IN VIOLATION | $25,000 |
| Jul 31, 2025 | Construction CLASS - 1 LARGE AND SMALL STORAGE ROOMS HAS INSERTED NEW WATER LINES FOR THE KITCHEN SINK AND 3-PIECE BATHROOM., OBTAIN PERMIT #39155662Z | Apr 16, 2027 PENDING | $12,500 |
| Jul 31, 2025 | Construction CLASS - 1 INSIDE ELECTRICAL FUSE BOX INSIDE LAUNDRY ROOM FUSES IS BEING JUMPED WITH WIRE. THOUGH CELLAR NEW WIRING DONE AND OLD WIRING NOT MAINTAINED. OBTAIN PERMITS FOR ALL ELECTRICAL WIRING DONE IN CELLAR AND MAINTAIN #39155659H | Sep 14, 2026 IN VIOLATION | $2,500 |
| Jul 31, 2025 | Construction CLASS - 1 FULL HEIGHT PARTITIONS HAS BEEN ERECTED FOR THE BATHROOMS LOCATED AT LARGE AND SMALL STORAGE ROOMS. ALSO, FULL HEIGHT PARTITION BEEN ERECTED IN LAUNDRY ROOM., OBTAIN PERMIT #39155665Y | May 3, 2027 PENDING | $12,500 |
| Jul 31, 2025 | Quality of Life CLASS - 1 ROOM2 2ND GAS METER ROOM AT END OF HALL, TURNED INTO LIVING ROOM AREA AND STORAGE UNIT FOR BUILDING., RESTORE TO PRIOR LEGAL CONDITION #39155666X | May 3, 2027 PENDING | $25,000 |
| Jul 30, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDERS TO FILE A CERTIFICATE OF CORRECTION WITH THE DOB FOR VIOLATION#39144554H, FILE A CERTIFICATE OF CORRECTION; FILER A CERTIFICATE OF CORRECTION #39155487K | Oct 3, 2025 IN VIOLATION | $0 |
| Jul 30, 2025 | Construction CLASS - 2 FAILURE TO COMPLY WITH THE COMMISSIONERS ORDERS TO FILE A CERTIFICATE OF CORRECTION WITH THE DOB FOR VIOLATION#39141911N, FILE A CERTIFICATE OF CORRECTION; FILE A CERTIFICATE OF CORRECTION #39155490L | Jan 23, 2026 IN VIOLATION | $1,250 |
| Jul 14, 2025 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG EXTERIOR FACADE AND APPURTENANCES. NOTE: AT TIME OF INSPECTION, I OBSERVED EXP #1 WEST, #4 SOUTH-CRACKED BRICK/MORTAR JOINTS MULTI LOC. AT PARAPET AND WINDOW SPANDRELS.-EXP #3 EAST-CRAC #35693999R | Sep 19, 2025 IN VIOLATION | $0 |
| Apr 10, 2025 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED, STEP CRACKS, MISSING/SPALLING MORTAR JOINTS AND MISSING/DISLODGED BRICKS AT MULTIPLE LOCATIONS AT EXP.1 (FRONT OF BUILDING), EXP.3 (REAR OF BUILDING) AND EXP.4 (RIGHT SIDE OF BUI #39144554H | Jun 20, 2025 IN VIOLATION | $0 |
| Feb 6, 2025 | Elevators CLASS - 1 CLASS 1 ITEM: FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITIO #39137674R | Jul 18, 2025 IN VIOLATION | $0 |
| Feb 6, 2025 | Elevators CLASS - 1 CEASE USE ITEM: DOOR ZONE RESTRICTOR INOPERATIVE. THIS IS A SAFETY FEATURE WHICH ENSURES PASSENGER SAFETY. REMEDY: TO RESTORE SERVICE, CALL OR EMAILTHE D.O.B. EIR@BUILDINGS.NYC.GOV. ELEVATOR DIVISION AT (212) 3 #39137675Z | Jul 18, 2025 IN VIOLATION | $0 |
| Aug 21, 2023 | Construction CLASS - 2 FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR NOV 39025008Z. REMEDY: FILE CERTIFICATE OF CORRECTION. #39093008N | Nov 17, 2023 IN VIOLATION | $0 |
| Aug 21, 2023 | Construction CLASS - 2 FAILURE TO CERTIFY: FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDINGS FOR NOV 39025011J. REMEDY: FILE CERTIFICATE OF CORRECTION. #39093014J | Nov 17, 2023 IN VIOLATION | $0 |
| Jun 26, 2023 | Elevators CLASS - 1 IN CAR COMMUNICATION INOPERATIVE, REPAIR. IN CAR ALARM INOPERATIVE, REPAIR. PIT DIRTY, CLEAN. ROUGE DEVELOPING ON HOIST CABLES, MONITOR AND TAKE APPROPRIATE ACTION. #39089174R | Sep 1, 2023 IN VIOLATION | $0 |
| Jun 26, 2023 | Elevators CLASS - 1 CEASE USE ITEM: ZONE RESTRICTOR TAMPERED WITH AND INOPERATIVE, REPAIR AND CONTACT DOB ELEVATOR DIVISION FOR A RE-INSPECTION TO HAVE SERVICE RESTORED. CLASS 2 ITEMS: PIT DIRTY, CLEAN. POSITION INDICATORS INOPERA #39089175Z | Sep 1, 2023 IN VIOLATION | $0 |
| Jul 7, 2020 | Elevators CLASS - 1 CLASS 1 NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER REMEDY; FILE APPLICATION, INSTALL DLM AND PERFORM AND FILE TEST WITH NYCDOB, PROVIDE LED SEAL ON GOVERNOR ADJUSTMENT SCREW, #39025011J | Nov 20, 2020 IN VIOLATION | $0 |
| Jul 7, 2020 | Elevators CLASS - 1 CLASS 1 NO DOOR LOCK MONITORING IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014NYCBC,. REMEDY; FILE APPLICATION, INSTALL DLM AND PERFORM AND FILE TEST WITH NYCDOB, CLASS 2 PROVIDE PROPER LE #39025008Z | Sep 18, 2020 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Apr 10, 2025 | CONSTRUCTION AT TIME OF INSPECTION OBSERVED, STEP CRACKS, MISSING/SPALLING MORTAR JOINTS AND MISSING/DISLODGED BRICKS AT MULTIPLE LOCATIONS AT EXP.1 (FRONT OF BUILDING), EXP.3 (REAR OF BUILDING) AND EXP.4 (RIGHT SIDE OF BUILDING). #25-00601 | DOB VIOLATION - ACTIVE |
| Jun 20, 2023 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION #07206 | DOB VIOLATION - ACTIVE |
| Oct 14, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00161 | DOB VIOLATION - ACTIVE |
| Oct 14, 2020 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00160 | DOB VIOLATION - ACTIVE |
| Oct 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST #01897 | DOB VIOLATION - ACTIVE |
| Oct 31, 2014 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST #01896 | DOB VIOLATION - ACTIVE |
| May 30, 2014 | (OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST #04902 | DOB VIOLATION - ACTIVE |
| Dec 13, 2011 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2010 INSPECTION/TEST #02345 | DOB VIOLATION - ACTIVE |
| May 28, 1992 | CONSTRUCTION #9W2 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 30, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2024 Periodic Inspection Affirmation of Correction | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Oct 11, 2024 | Elevators FTC-VT-PER-CO Violation Issued-Failure To File 2023 Periodic Inspection Affirmation of Correction | Active |
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device | Active |
| Jun 20, 2023 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Oct 14, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 14, 2020 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 31, 2014 | Elevators EVCAT1 | Active |
| Oct 31, 2014 | Elevators EVCAT1 | Active |
| May 30, 2014 | Elevators ACC1 | Active |
| Dec 13, 2011 | Elevators EVCAT1 | Active |
| Dec 13, 2011 | Elevators EVCAT1 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jul 31, 2024 | C | Apt 3B · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQ. FT AT EAST WALL AND NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 3B, 3rd STORY, 5th APARTMENT FROM NORTH AT EAST | Aug 26, 2024 |
| Nov 27, 2020 | C | Apt 5G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 3rd APARTMENT FROM SOUTH AT WEST | Dec 23, 2020 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 30, 2026 | DOB Safety | AEUHAZ: | Open |
| Sep 17, 2026 | ECB | Elevators: : FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE. REMEDY: RESTORE TO SERVICE. | Open |
| Jul 22, 2026 | ECB | Construction: AT TIME OF INSPECTION, OCCUPIED 6-STORY BUILDING OBSERVED WITH SIDEWALK SHED LIGHTING NOT PROPERLY MAINTAINED. ONLY MINIMAL LIGHTING WAS PROVIDED BENEATH THE SHED, LEAVING PORTIONS OF THE PEDESTRIAN WALKWAY INA | Open |
| Jul 22, 2026 | ECB | Unknown: AT TIME OF INSPECTION, OCCUPIED 6-STORY BUILDING OBSERVED WITH SIDEWALK SHED PERMIT #X01211409 EXPIRED ON 06/06/2026. SIDEWALK SHED IN PLACE WITHOUT A VALID PERMIT. FAILURE TO MAINTAIN A VALID PERMIT FOR PEDEST | Open |
| Jul 13, 2026 | HPD A | §27-2104(B) HMC POST A PROPER NOTICE REGARDING RENT STABILIZATION LAW, IN A FORM APPROVED BY THE COMMISSIONER, IN A CONSPICUOUS LOCATION WITHIN THE COMMON AREA AT THE BUILDINGS ENTRANCE. FOR MORE INFORMATION ABOUT SIGNAGE REQUIREMENTS, PLEASE VISIT: HTTPS://WWW.NYC.GOV/SITE/HPD/SERVICES-AND-INFORMA | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 1:04 AM ET. BBL 2033470001.