Manhattan · Block 391 · Lot 47 · 10009

325 East 8 Street

6 floors · 13 apartments · 9,046 sq ft · built 2000 · class D1 · owner of record: City Jam, .

12open violations
$0ECB/OATH penalties owed
3HPD class C (immediately hazardous)
43dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 43 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 59 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 287 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 774 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-11-10 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Oct 31, 2019Elevators CLASS - 2
81Y13,70O02,2X10,68B7,57BB11: 81Y13 CYLINDER PISTON OIL LEAK 70O02 REMOVE EXCESS OIL FROM PIT 02X10 ALARM BELL 68 LOG BOOK NOT UP TO DATE 57BB11 FIRE EXTINGUISHER NEEDS TO BE REPLACED
#38272182X
Jan 9, 2020
STIPULATION/IN-VIO
$0
DOB (5)
IssuedViolationStatus
Jul 1, 2021ELEVATOR

#9027/705417
DOB VIOLATION - ACTIVE
May 26, 2020ELEVATOR

#9027/682060
DOB VIOLATION - ACTIVE
Sep 6, 2019(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2017 CAT 1 INSP/TST TST
#06872
DOB VIOLATION - ACTIVE
Sep 6, 2019ELEVATOR

#9027/659980
DOB VIOLATION - ACTIVE
Jan 26, 2018(OTHER BLDGS TYPES) - ELEVATOR AFFIRMATION OF CORRECTION
VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2016 CAT 1 INSP/TST
#08407
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Sep 6, 2019Elevators ACC1
Active
Jan 26, 2018Elevators ACC1
Active
HPD (4) · C 3 · B 0 · A 1
IssuedClassViolationCorrect by
Mar 6, 2018A§ 27-2005 ADM CODE REPLACE WITH NEW THE MISSING COVERS OR CAPS AT ELECTRIC WALL OUTLET AT PUBLIC HALL, 5th STORYJun 9, 2018
Nov 28, 2012CApt 2A · SECTION 27-2029 ADM CODE DEVICE PRESENT ON CENTRAL HEATING SYSTEM WHICH IS CAPABLE OF CAUSING AN OTHERWISE OPERABLE SYSTEM TO BECOME INOPERABLE DAMAGED BOILER & HOT WATER HEATER IN CELLAR BOILER ROOM IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHNov 24, 2012
Nov 26, 2012CSECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM , , 1st STORYDec 2, 2012
Nov 26, 2012CSECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOM IN CELLARDec 2, 2012

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 2:26 PM ET. BBL 1003910047.