Bronx · Block 2572 · Lot 1 · 10454

324 Powers Avenue

6 floors · 60 apartments · 39,095 sq ft · built 1920 · class D1 · owner of record: Diego Beekman Mutual Housing Assoc Housi Ng Development Fund Corp

57open violations
$42,500ECB/OATH penalties owed
3HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 67 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 67 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 83 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 39,095 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 188 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 188 days
Annual filing
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 798 days
Next cycle year 2028
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-20 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (9) · $42,500 owed
IssuedViolationHearingBalance
Mar 19, 2026Construction CLASS - 2
FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS NUMBER 35683158N, FILE A CERTIFICATE OF CORRECTION
#39181118Y
May 17, 2027
DEFAULT
$6,250
Mar 19, 2026Construction CLASS - 2
FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS NUMBER 35683159P, FILE A CERTIFICATE OF CORRECTION
#39181117M
May 17, 2027
DEFAULT
$6,250
Mar 19, 2026Construction CLASS - 2
PARAPET REPAIRED, APPROVED JOB X01229312 FOR REPAIR WORK - HOWEVER PERMITS NOT ISSUED, OBTAIN ALL PERMITS
#39181120N
May 18, 2027
DEFAULT
$6,250
Mar 19, 2026Construction CLASS - 2
FAILURE TO CERTIFY CORRECTIONS FOR VIOLATIONS NUMBER 35683156J, FILE A CERTIFICATE OF CORRECTION
#39181119X
May 18, 2027
DEFAULT
$6,250
Aug 22, 2025Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S PRDER #061325PI201025B AND CONTROL #34154 DATED 06/13/25. NO COMPLIANCE ON FILE FOR A CORRECTIVE ACTION PLAN. REMEDY: COMPLY WITH THE COMMISSIONER'S ORDER AND/OR FILE A
#35719057X
Oct 31, 2025
IN VIOLATION
$0
Apr 18, 2025Cranes and Derricks CLASS - 2
FAILED TO NOTIFY DEPARTMENT OF BUILDINGS PRIOR TO INSTALLATION OR REMOVAL OF SUSPENDED SCAFFOLD. NOTE: AT TIME OF INSPECTION, A C HOOK SUSPENDED SCAFFOLD HAS BEEN INSTALLED AT THE STRUCTURALLY COMPROMISED PARAP
#35683157L
Jan 9, 2026
IN VIOLATION
$2,500
Apr 18, 2025Construction CLASS - 1
FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONOPERATIONS. A PROACTIVE INSPECTION WAS CONDUCTED AT 324 POWERS AVENUE,BRONX ON APRIL 17, 2025. THE PI OBSERVED A SIGNIFICANT VERTICAL CRACK
#35683159P
Jan 9, 2026
IN VIOLATION
$10,000
Apr 18, 2025Construction CLASS - 1
WORK WITHOUT A PERMIT. AT TIME OF INSPECTION, A C HOOK SUSPENDED SCAFFOLD HAD BEEN INSTALLED AT THE STRUCTURALLY COMPROMISED PARAPET AT EXPOSURE 1/2 CORNER, AND A CONSTRUCTION WORKER WAS PERFORMINH CONSTRUCTION
#35683158N
Jan 9, 2026
IN VIOLATION
$2,500
Apr 17, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. I OBSERVED HAZARDOUS CONDITION WITH AN APPROX. EIGHT-FOOT VERTICAL CRACK ALONG EXTERIOR WALL AND THE PARAPET WALL OF EXPOSURE TWO AND THREE, BOTH CRACKS
#35683156J
Jan 9, 2026
IN VIOLATION
$2,500
DOB (9)
IssuedViolationStatus
Jun 13, 2025CONSTRUCTION
CORRECTION ACTION PLAN REQ'D.OBSV @ EXP2 @ EXP3 AN EXPANDING MASONRY CRACK APPROX 1/2 WIDE @ PARAPET LEVEL.ALSO OBSVA CRACK GLASS WINDOW ON THE 5FL OF EXP3 COURTYARD.OWNER TO IMMED RETAIN REG DESIGN PROF TO EVAL ENTIRE BLDG& TO SUBMIT CORRECTIVE ACTION PLAN WITHIN 30 DAYS
#PI20102SB
DOB VIOLATION - ACTIVE
Apr 18, 2025IMMEDIATE EMERGENCY
REMEDY: EXPO 1 APPROX 120 LF OF SIDEWALK SHED SHALL BE ERECTED ALONG T HE FULL WIDTH OF THE FACADE, WITH AN EXTENSION OF 15LF WRAPPING AROUND TOWARD EXPO 2. AT EXPO 4 APPROX 110 LF OF SIDEWALK SHED SHALL BE EREC TED ALONG FULL WIDTH OF THE FACADE W/ AN EXTENSION OF 15LF WRAPPING AR PUND TOWARD EXPO
#19163
DOB VIOLATION - ACTIVE
Apr 18, 2025CONSTRUCTION
EMERGENCY WORK ORDER.EXP1 ALONG 324 POWERS AVE&EXP4 ALONG E141ST THE EXP1/2&EXP3/4 EXTERIOR MASONRY WALLS NEAR THE ROOF CORNERS EXHIBITED SIGNIFICANT VERTICAL CRCKS,SEPARATION&POSNG RISK OF CLLPSE.OWNR TO IMMED RTAIN A NYSPE&DOB REG CNTRCTR TO 1.IMMED PRVDE TEMP BRACNG TO STBLIZE EXP1,2,3&4 WALLS,2.
#FEU20105ZT
DOB VIOLATION - ACTIVE
Apr 18, 2025CONSTRUCTION
FAILURE TO MAINTAIN A BLDG IN A SAFE CONDITION.THE EXP 1/2 EXTERIOR MASONRY WALL NEAR THE ROOF CORNERS EXHIBITED SIGNIFICANT VERTICAL CRCKS,SEPARATION &IN THE BIRITY,POSNG A RISK OF.OWNR TO IMMED RTAIN NYSPE TO EVAL THE ENT BLDG,DETERMINE THE STRCTRL STBILITY.&PREPARE/ FILE RPAIR DWGS.BLDG TO BE RPA
#FEU20104ZT
DOB VIOLATION - ACTIVE
Apr 17, 2025CONSTRUCTION
CORRECTION ACTION PLAN REQ'D. OBSV @ EXP2 & EXP3 AN EXPANDING MASONRY CRACK APPROX 1/2 WIDE @ PARAPET LEVEL ALSO OBSV CRACK GLASS WINDOW ON THE 5FL OF EXP3 COURTYARD & SPALLING/CRACKED MASONRY @ CHIMNEY OWNER TO IMMED RETAIN REG DESING PROF TO EVAL ENTIRE BLDG & TO SUBMIT CORRECTIVE ACTION PLAN TO P
#PI20101HZ
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#05263
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#05262
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
#04906
DOB VIOLATION - ACTIVE
May 31, 1994LOCAL LAW 10/81 - ELEVATOR

#03388
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction
Active
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
Mar 31, 2014Elevators EVCAT1
Active
HPD (31) · C 3 · B 24 · A 4
IssuedClassViolationCorrect by
Jan 26, 2024BApt 3A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX (25) SQ FT AT CEILING, SOUTH, AND WEST WALLS IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM NORTH AT EASTMar 1, 2024
Jan 26, 2024BApt 3A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM NORTH AT EASTMar 1, 2024
Jan 26, 2024BApt 3A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, SOUTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 2nd APARTMENT FROM NORTH AT EASTMar 1, 2024
Nov 27, 2023AApt 3A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WESTMar 1, 2024
Nov 27, 2023BApt 3A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... TEN SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WESTJan 1, 2024
Nov 27, 2023BApt 3A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WESTJan 1, 2024
Nov 27, 2023BApt 3A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WESTJan 1, 2024
Nov 27, 2023BApt 3A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WESTJan 1, 2024
Nov 27, 2023AApt 3A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WEST AND SOUTH WALL IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WESTMar 1, 2024
Nov 27, 2023AApt 3A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE BATHROOM LOCATED AT APT 3A, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WESTMar 1, 2024
Jul 20, 2022AApt 2A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 3rd ROOM FROM EAST AT SOUTH, THE BATHROOM , THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTOct 23, 2022
Jul 20, 2022BApt 2A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTAug 24, 2022
Jul 20, 2022BApt 2A · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTAug 24, 2022
Sep 1, 2021CApt 5H · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5H, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTSep 27, 2021
Sep 1, 2021BApt 5H · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTOct 6, 2021
Sep 1, 2021BApt 5H · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTOct 6, 2021
Sep 1, 2021BApt 5H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, WEST AND NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTOct 6, 2021
Sep 1, 2021BApt 5H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WINDOW CASINGS IN THE 2nd ROOM FROM NORTH LOCATED AT APT 5H, 5th STORY, 3rd APARTMENT FROM SOUTH AT WESTOct 6, 2021
Aug 26, 2021BApt 5H · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING, NORTH SOUTH AND WEST WALLS IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 5H, 5th STORY, 2nd APARTMENT FROM SOUTH AT WESTSep 30, 2021
Jul 22, 2021CApt 5E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHAug 17, 2021
Jul 22, 2021BApt 5E · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE ELECTRICAL OUTLET AT SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHAug 26, 2021
Jul 22, 2021BApt 5E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHAug 26, 2021
Jul 22, 2021BApt 5E · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHAug 26, 2021
Jul 22, 2021BApt 5E · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHAug 26, 2021
Jul 22, 2021BApt 5E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHAug 26, 2021
Jul 22, 2021BApt 5E · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHAug 26, 2021
Jul 22, 2021BApt 5E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND SOUTH WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 5E, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHAug 26, 2021
Nov 6, 2020CApt 1J · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1J, 1st STORY, 1st APARTMENT FROM WEST AT NORTHDec 2, 2020
May 13, 2019BApt 5F · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND WEST AND EAST WALLS IN THE 1st BEDROOM FROM EAST LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJun 17, 2019
Nov 30, 2017BApt 5F · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH WINDOW SPRING BALANCES IN THE 3rd ROOM FROM NORTH LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 4, 2018
Nov 30, 2017BApt 5F · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE LOWER SASH WINDOW SPRING BALANCES IN THE 1st ROOM FROM NORTH LOCATED AT APT 5F, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 4, 2018

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 25, 2026, 6:56 PM ET. BBL 2025720001.

Look up another building