Brooklyn · Block 3838 · Lot 1 · 11207

323 New Lots Avenue

2 floors · 1 apartments · 2,800 sq ft · built 1920 · class S1 · owner of record: Rios Lydia

30open violations
$0ECB/OATH penalties owed
2HPD class C (immediately hazardous)
1154dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 58 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 302 days
Required only if the owner doesn't live there
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1154 days
Next cycle year 2029

Open violations

ECB / OATH (10)
IssuedViolationHearingBalance
Mar 1, 2008Unknown Non-Hazardous
ILLEGAL USE IN RESIDENTIAL DISTRICT. SCHOOL BUS W/O LICENSE PLATES IS PARKED OUT THE PROPERTY. REMEDY: REMOVE DEAD STORAGE.
#34631132Y
May 28, 2008
WRITTEN OFF
$0
Jan 19, 2006Construction Hazardous
FAILURE TO MAINTAIN BLDG. HAZARDOUS. NOTED: THERE ARE 7 WINDOWS MISSING AT THE WEST AND NORTHSIDE. AT THE BACK GARAGES (3 OF THEM) MISSING THE ROOF PARAPET WALL. EXPOSING ROOF JOIST BEAMS. REMEDY: MAINTAIN BLDG
#34507518Z
Mar 6, 2006
WRITTEN OFF
$0
Jan 7, 2006Construction Non-Hazardous
FAILURE TO MAINTAIN BLDG (EXTERIOR): NOTED: ABOVE 2ND STY WINDOW (FRONT) HOLES PRESENT IN JOINTS AT BRICKWORK, LOOSE BRICK AT WINDOW SIDE. REMEDY: MAKE AREA SAFE, MAKE ALL NECESSARY REPAIRS.
#34484647X
Feb 27, 2006
WRITTEN OFF
$0
Sep 20, 2005Construction Hazardous
FAILURE TO MAINTAIN. NOTE: ONE STORY REAR MASONRY ADDITION HAS MISSINGPARAPET AT THE FRONT. ALSO,THE WEST AND SOUTH FACES (FACADE) OF THE ORIGINAL BLDG HAVE SEVERE STRESS CRACKS WITH THE SOUTH WEST CORNER LEANI
#34405816J
Nov 7, 2005
WRITTEN OFF
$0
May 20, 2005Construction Hazardous
FAILURE TO MAINTAIN. DEFECT NOTED: FIRST STORY MASONRY ADDITION HAS MISSING PARAPET AT THE FRONT. THE WEST AND SOUTH FACADE OF THE ORIGINAL BLDG HAS SEVERE STRESS CRACKS WITH THE SOUTH WEST CORNER LEANING OUT O
#34473315X
Jul 11, 2005
WRITTEN OFF
$0
Jan 12, 2005Construction Hazardous
FAILURE TO MAINTAIN: DEFECT NOTED- 1) 1 STORY MASONRY ADDITION HAS MISSING PARAPET AND FRONT; ALSO SECTION AT SIDE HAS SEVERE STRESS CRACKS AND OUT OF PLUMB. 2) METAL ROLL DOWN GATE IS LOOSE AND IN DANGER OF
#34492651Z
Feb 28, 2005
WRITTEN OFF
$0
Aug 18, 2004Construction Hazardous
FAILURE TO MAINTAIN:DEFECTS NOTED:1)FLOORS THROUGHOUT ARE OUT OF PLUMB.2)INTERIOR WALLS & CEILINGS ARE MISSING,SHEATHING EXPOSING STRUCTURAL MEMBERS.3)SEVERE INTERIOR STRESS CRACKS AT MASONRY WALL.4)VARIOUS DEB
#34451192H
Dec 13, 2004
WRITTEN OFF
$0
Aug 18, 2004Construction Hazardous
FAILURE TO MAINTAIN:DEFECTS NOTED:1)1 STORY MASONRY ADDITION HAS MISSING PARAPET AT FRONT WITH SECTION AT SIDE WITH SEVERE STRESS CRACKSAND OUT OF PLUMB.2)METAL ROLL DOWN GATE IS LOOSE & IN DANGER OF FALLING.3)
#34451191X
Dec 13, 2004
WRITTEN OFF
$0
Feb 20, 2000Construction Non-Hazardous
WORK WITHOUT PERMITS. WORK NOTED: INSTALLING NEW PARTITIONS ON THE SECOND (2) FLOOR. INSTALLING NEW BATH AND KITCHEN. REMENDY: OBTAIN PERMITS.
#34273336Z
Mar 12, 2001
WRITTEN OFF
$0
May 12, 1998Construction Non-Hazardous
FAILURE TO MAINTAIN BUILDING EXTERIOR WALL: DEFECT IS: CRACKED BRICK WORK AT ONE STORY STRUCTURE AT REAR, PARAPET WALL. REMEDY: REPAIR THE CRWAKCED PARAPET WALL.
#34182229J
Jul 2, 1998
WRITTEN OFF
$0
DOB (3)
IssuedViolationStatus
Dec 20, 2000CONSTRUCTION

#05TC03
DOB VIOLATION - ACTIVE
Dec 20, 2000CONSTRUCTION
WORK WITHOUT A PERMIT - INSTALLING NEW PARTITIONS ON THE SECOND FLOOR INSTALLING NEW BATH AND KITCHEN
#05TC04
VIOLATION WORK WITHOUT PERMIT - ACTIVE
May 11, 1998UNSAFE BUILDINGS

#3057/98
DOB VIOLATION
DOB NOW Safety (0)

None open.

HPD (17) · C 2 · B 5 · A 10
IssuedClassViolationCorrect by
Jun 11, 2008B§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING SASH CHAINS, LOWER SASH REAR ROOM -2ND STY APT #2.Jul 16, 2008
Jun 11, 2008B§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING BALUSTERS, 2ND STY PUBLIC HALL.Jul 16, 2008
Jun 11, 2008B§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES THROUGHOUT 2ND STY NORTH APT.Jul 16, 2008
Jun 11, 2008A§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING FAUCET HANDLE HOT WATER, KITCHEN SINK, 2ND STY NORTH APT.Sep 14, 2008
Jun 11, 2008A§ 27-2026 ADMIN. CODE: REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS KITCHEN SINK, 2ND STY NORTH APT.Sep 14, 2008
Jun 11, 2008A§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE CEILING LIGHT FIXTURE NORTHEAST ROOM, 2ND STY NORTH APT.Sep 14, 2008
Jun 11, 2008A§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAIL BOXES, VESTIBULE.Sep 14, 2008
Jun 11, 2008A§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE,VESTIBULE.Sep 14, 2008
Jun 11, 2008C§ 27-2031 ADMIN. CODE: PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2 STY.NORTH APT.Jun 17, 2008
Jun 11, 2008A§ 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PLASTER BOARD-CELLAR CEILING THROUGHOUT.Sep 14, 2008
Jun 11, 2008A§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE MAIL BOXES VESTIBULE.Sep 14, 2008
Jun 11, 2008A§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE ELECTRIC CEILING FIXTURE VESTIBULE.Sep 14, 2008
Jun 11, 2008B§ 27-2024 ADMIN. CODE: PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT BATHTUB IN BATHROOM, 2ND STY SOUTH APT #1.Jul 16, 2008
Jun 11, 2008B§ 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE HANDLE ON COMBINATION DECK FAUCET OF KITCHEN SINK, 2ND STY APT #2 NORTH.Jul 16, 2008
Jun 11, 2008A§ 27-2041 ADMIN. CODE: PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED AS TO PERMIT A PERSON INSIDE THE DWELLING UNIT TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR 2ND STORY NORTH APARTMENT.Sep 14, 2008
Jun 11, 2008A§ 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING DOOR KNOB, VESTIBULE.Sep 14, 2008
Jul 3, 2006C§ 27-2005 ADMIN. CODE: PROVIDE TEMPORARY SEAL TO ALL ACCESSIBLE OPENINGSJul 21, 2006

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 3, 2026, 4:46 PM ET. BBL 3038380001.