Manhattan · Block 1444 · Lot 13 · 10021

321 East 69 Street

5 floors · 40 apartments · 23,252 sq ft · built 1920 · class D6 · owner of record: 321 East 69th Street

22open violations
$4,913ECB/OATH penalties owed
3HPD class C (immediately hazardous)
45dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 45 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 45 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 61 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 289 days
Registered through 2027-09-01
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-02-10 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (8) · $4,913 owed
IssuedViolationHearingBalance
Nov 16, 2023Elevators CLASS - 2
MISALIGNED CAB MIRROR. REPLACE WORN GIBS WHERE NEEDED. SECURE GIBS WHERE NEEDED. PROVIDE MISSING HOISTWAY DOOR SIGHT GUARDS WHERE NEEDED. MISSING IN CASE OF FIRE SIGNS. UNGUARDED SUMP PUMP. INAUDIBLE ALARM BELL
#39099478P
Jan 25, 2024
ADMIT/IN-VIO
$0
Oct 11, 2023Construction CLASS - 2
SIDEWALK SHED AT EXPOSURE 1, RESPONDENT FAILED TO MAINTAIN THE DECKS OF SIDEWALK SHEDS CLEAN, HAS DEBRIS, COMBUSTIBLE MATERIALS, AND TOOLS, CREATING HAZARDOUS OF START FIRE AND OR FALL DEBRIS ALSO IN CONTRARY W
#39522492R
Dec 21, 2023
ADMIT/IN-VIO
$0
Oct 11, 2023Construction CLASS - 1
PERMITHOLDER FAILED TO MAINTAIN SCAFFOLD AS PER CODE REQUIREMENTS. OBSERVED SCAFFOLD WAS MISSING TOE BOARD, SOME AREAS NOT FULLY PLANKED, AND IT WAS LOOSE, DOME OTHER AREAS HAS MORE THAN ONE INCH SPACE BETWEEN
#39522493Z
Dec 21, 2023
ADMIT/IN-VIO
$0
Aug 23, 2023Construction CLASS - 1
AT THE TIME OF INSPECTION, OBSERVED WORKERS ON INADEQUATELY MAINTAINED SUPPORTED SCAFFOLD OVER SIDEWALK SHED DOING FACADE ALTERATION WORK. LOOSE PLANKS, UNPROTECTED OPEN PERIMETER, MAKE SHIFT PULLY ATTACHED TO
#39520883P
Nov 2, 2023
ADMIT/IN-VIO
$0
Aug 23, 2023Construction CLASS - 2
AT THE TIME OF INSPECTION, OBSERVED MISSING BLIND SPOT MIRROR BY DRIVE WAY. PROVIDE BLIND SPOT MIRROR AS PER CODE.
#39520884R
Nov 2, 2023
ADMIT/IN-VIO
$0
Jun 8, 2021Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY ; NOTED AT REAR YARD NORTHWEST FIRE ESCAPE, EGRESS FROM FIRE ESCAPE TO REAR BASEMENT DOOR BLOCKED BY (3) 6 FOOT HIGH WOODEN FENCES. ALSO AT CELLAR LEVEL HALLWAY A
#39042472R
Jul 14, 2022
IN VIOLATION
$1,250
Jun 8, 2021Construction CLASS - 1
WORK WITHOUT PERMIT; NOTED AT APARTMENT 1A CUT HOLE IN FLOOR APPROXIMATELY 3' X 7' TO INSTALL WOODEN STAIR CASE THAT LEADS DOWN TO ADDITIONAL ROOM IN CELLAR TO CREATE DUPLEX APARTMENT. INSTALLED ADDITIONAL DOOR
#39042471P
Jul 14, 2022
IN VIOLATION
$2,500
Jun 8, 2021Construction CLASS - 2
OCCUPANCY CONTRARY; NOTED CERTIFICATE OF OCCUPANCY #112323 INDICATES BUILDING TO BE 7 STORY 41 APARTMENTS. FIRST FLOOR AS 8 APARTMENT. NOTED; OCCUPANCY CONTRARY OBSERVED AT APARTMENT 1A, NOW SET UP AS A DUPLEX
#39042473Z
Jul 14, 2022
IN VIOLATION
$1,163
DOB (1)
IssuedViolationStatus
Oct 10, 1991CONSTRUCTION

#B4FB02
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
Oct 23, 2023Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction
Active
HPD (14) · C 3 · B 8 · A 3
IssuedClassViolationCorrect by
Oct 30, 2026BApt APT6A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER AND UPPER SASHES AT 1ST WINDOW FROM EAST AT SOUTH IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT APT6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHDec 4, 2026
Oct 30, 2026AApt APT6A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 2nd ROOM FROM NORTH AT WEST, THE 2nd ROOM FROM NORTH AT EAST, THE BATHROOM LOCATED AT APT APT6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHFeb 2, 2027
Oct 6, 2026BApt 6C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM WEST AT NORTHNov 10, 2026
Oct 6, 2026BApt 6C · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM WEST AT NORTHNov 10, 2026
Oct 27, 2023C§27-2005 (E) HMC: PROVIDE WRITTEN NOTICE TO THE TENANTS AT LEAST TWENTY-FOUR HOURS PRIOR TO ESSENTIAL SERVICE INTERRUPTION BY POSTING A NOTICE IN A PROMINENT PLACE WITHIN THE PUBLIC PART OF THE BUILDING AND ON EACH FLOOR OF SUCH BUILDING, WHERE AN OWNER MUST MAKE A REPAIR THAT MAY RESULT IN AN INTERNov 2, 2023
Oct 27, 2023C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSINGNov 2, 2023
Aug 28, 2023A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING FRAME AT PUBLIC HALL, 1st STORYDec 1, 2023
Aug 28, 2023B§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF EIGHT FOOT METAL LADDER AT 1ST STORY LANDING AT PUBLIC HALL STAIRS, 1st STORYOct 2, 2023
Aug 15, 2023CApt 4C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE (HINGES) IN THE ENTRANCE LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHAug 29, 2023
Aug 15, 2023BApt 1C · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHSep 19, 2023
Aug 15, 2023BApt 1C · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHSep 19, 2023
Sep 10, 2021A§ 27-2014 ADM CODE AND DEPT. RULES AND REGULATIONS. SCRAPE AND REMOVE RUST SCALES AND PAINT WITH 2 COATS OF PAINT ALL COMPONETS AND ALL BALCONIES AT ALL STORIES AT FIRE ESCAPE AT SOUTH.Dec 14, 2021
Jun 7, 2021BApt 4C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APROX 10 SQ FT AT CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 12, 2021
Jun 7, 2021BApt 4C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APROX 10 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 12, 2021

Issued in the last 120 days

DateSourceWhatNow
Oct 30, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER AND UPPER SASHES AT 1ST WINDOW FROM EAST AT SOUTH IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT APT APT6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Oct 30, 2026HPD A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 2nd ROOM FROM NORTH AT WEST, THE 2nd ROOM FROM NORTH AT EAST, THE BATHROOM LOCATED AT APT APT6A, 6th STORY, 1st APARTMENT FROM EAST AT SOUTHOpen
Oct 6, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Oct 6, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 6C, 6th STORY, 1st APARTMENT FROM WEST AT NORTHOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 10:46 PM ET. BBL 1014440013.