5 floors · 35 apartments · 33,750 sq ft · built 1924 · class C1 · owner of record: Harta Realty Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 65 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 81 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 33,750 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1161 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-22 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Nov 8, 2019 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT #03751 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2023 | Boiler FTC-BE-EXT-LP Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device | Active |
| Nov 8, 2019 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 16, 2025 | B | Apt 4G · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SEC | Oct 21, 2025 |
| Sep 16, 2025 | A | Apt 4G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GASKET AROUND LOWER REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST | Dec 20, 2025 |
| Sep 9, 2025 | C | Apt 2G · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT DOOR LEADING TO FIRE ESCAPE IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''WEST'' | Sep 15, 2025 |
| Mar 5, 2025 | A | Apt 4G · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 4G, 4th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''WEST'' | Jun 8, 2025 |
| Dec 15, 2023 | C | Apt 5G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH | Jan 10, 2024 |
| Dec 15, 2023 | C | Apt 5G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 5G, 5th STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT NORTH | Jan 10, 2024 |
| Jul 3, 2023 | B | Apt 4A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 7, 2023 |
| Jul 3, 2023 | C | Apt 4A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jul 29, 2023 |
| Jul 3, 2023 | B | Apt 4A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WOOD BASE CABINET AT SINK IN THE KITCHEN LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 7, 2023 |
| Jul 3, 2023 | B | Apt 4A · § 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 7, 2023 |
| Jul 3, 2023 | B | Apt 4A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SPRING BALANCE LOWER SASH WINDOW AT 1ST WINDOW FROM SOUTH AT WEST WALL IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 7, 2023 |
| Jul 3, 2023 | B | Apt 4A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 7, 2023 |
| Jan 23, 2023 | C | Apt 3E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WEST | Feb 18, 2023 |
| Jan 23, 2023 | C | Apt 2G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST | Feb 18, 2023 |
| Jan 23, 2023 | C | Apt 3F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WEST | Feb 18, 2023 |
| Jan 23, 2023 | C | Apt 3F · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT WEST | Feb 18, 2023 |
| Jan 23, 2023 | C | Apt 3E · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WEST | Feb 18, 2023 |
| Jan 23, 2023 | C | Apt 2G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST | Feb 18, 2023 |
| Jan 23, 2023 | B | Apt 3E · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING DOOR KNOB IN THE ENTRANCE LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT WEST | Feb 27, 2023 |
| Dec 9, 2022 | C | Apt 2G · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 2G, 2nd STORY, 1st APARTMENT FROM WEST AT NORTH | Jan 4, 2023 |
| Dec 6, 2022 | B | Apt 2D · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 2D, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION '' | Jan 10, 2023 |
| Dec 6, 2022 | B | Apt 4D · § 27-2056.7, 27-2056.17 AND 27-2056.8 ADM CODE - CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY SUBMITTING REQUIRED SUPPORTING DOCUMENTATION AND AFFIDAVITS FOR APARTMENT LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 10, 2023 |
| Dec 2, 2022 | C | Apt 1F · § 27-2056.4 ADM CODE- CORRECT FAILURE TO NOTIFY OCCUPANTS AND/OR TO INVESTIGATE LEAD-BASED PAINT HAZARDS. | Dec 6, 2022 |
| Dec 2, 2022 | C | Apt 1F · § 27-2056.7 ADM CODE: CORRECT FAILURE TO PROVIDE TO THE DEPARTMENT WITHIN 45 DAYS OF DEMAND ALL RECORDS REQUIRED TO BE MAINTAINED BY OWNER PURSUANT TO LOCAL LAW 1 OF 2004 RELATED TO LEAD-BASED PAINT NOTICES, INSPECTIONS AND REMEDIATION/ABATEMENT ACTIVITIES. | Dec 6, 2022 |
| Nov 1, 2022 | A | Apt 4D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM NORTH AT EAST LOCATED AT APT 4D, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 4, 2023 |
| Sep 7, 2021 | A | Apt 4A · § 27-2005 ADM CODE REFIT WALL CABINET DOORS AND SINK CABINET DOORS AT EAST WALL IN THE KITCHEN LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT EAST | Dec 11, 2021 |
| Sep 7, 2021 | C | Apt 4A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT EAST | Oct 3, 2021 |
| Sep 7, 2021 | C | Apt 4A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT EAST | Oct 3, 2021 |
| Sep 7, 2021 | B | Apt 4A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT EAST | Oct 12, 2021 |
| Sep 7, 2021 | B | Apt 4A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT EAST | Oct 12, 2021 |
| Jun 29, 2021 | A | Apt 4A · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE BASE CABINET T EAST WALL IN THE KITCHEN LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 2, 2021 |
| Jun 29, 2021 | B | Apt 4A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''EAST'' | Aug 3, 2021 |
| Jun 29, 2021 | B | Apt 4A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION ''EAST'' | Aug 3, 2021 |
| Jun 29, 2021 | C | Apt 4A · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION ''EAST'' | Jul 25, 2021 |
| Oct 22, 2019 | B | Apt 4A · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASH SPRING BALANCE AT WINDOW IN THE KITCHEN LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 26, 2019 |
| Oct 22, 2019 | A | Apt 4A · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOWER SASH SPRING BALANCE AT WINDOW IN THE 4th ROOM FROM EAST AT SOUTH LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 25, 2020 |
| Oct 22, 2019 | A | Apt 4A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILINGS AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 25, 2020 |
| Sep 9, 2019 | B | Apt 3E · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE APARTMENT DOOR MOTISE LOCK. IN THE ENTRANCE LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT EAST | Oct 14, 2019 |
| Apr 8, 2019 | C | Apt 1C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 29, 2019 |
| Apr 8, 2019 | C | Apt 1C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 1C, 1st STORY, 1st APARTMENT FROM NORTH AT EAST | Apr 29, 2019 |
| Dec 10, 2018 | B | Apt 4A · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... CEILING APRROX 1 SQ FT SOUTH WALL APPROX 1 SQ FT IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 14, 2019 |
| Oct 11, 2016 | B | Apt 4A · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH AT SOUTH WALL WINDOW IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH | Nov 15, 2016 |
| Oct 11, 2016 | B | Apt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL CEILINGS AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM EAST AT SOUTH , SECTION AT NORTH | Nov 15, 2016 |
| Dec 3, 2014 | A | Apt 4A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AT RISER IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT EAST | Mar 8, 2015 |
| Nov 12, 2014 | A | Apt 4A · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 15, 2015 |
| Nov 12, 2014 | A | Apt 4A · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING ESCUTCHEON PLATE AT THE TOP OF THE HEAT RISER IN THE 1st ROOM FROM NORTH AT WEST LOCATED AT APT 4A, 4th STORY, 1st APARTMENT FROM SOUTH AT WEST | Feb 15, 2015 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)