Manhattan · Block 1346 · Lot 7501 · 10022

320 East 54 Street

12 floors · 90 apartments · 61,630 sq ft · built 1959 · class R4 · owner of record: 320 East 54th St Condo

32open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
45dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 45 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 45 days
Keep the report on file (not filed with DOB)
Energy audit and retro-commissioning (2026) Likely applies
Local Law 87 · Calendar year 2026
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1346). Agency page

Dec 31, 2026
in 45 days
Due this year
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 45 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 61 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 97 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 61,630 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 166 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 166 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 289 days
Registered through 2027-09-01
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-08-11 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (1)
IssuedViolationHearingBalance
Mar 14, 2005Construction Non-Hazardous
FAILURE TO PROVIDE APPROVED PLANS ALTERATION TYPE I # 104019660 EXP 7/18/05 AT TIME OF INSPECTION REMEDY:STOP ALL WORK EXCEPT TO MAKE SAFE OBTAIN APPROVED PLANS OBTAIN STOP WORK RESEND ORDER BEFORE RETURNING
#34465097R
Jul 7, 2005
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Dec 31, 2009LOW PRESSURE BOILER

#02598
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
May 30, 2014Elevators ACC1
Active
May 30, 2014Elevators ACC1
Active
Dec 31, 2009Boiler LBLVIO
Active
HPD (27) · C 1 · B 22 · A 4
IssuedClassViolationCorrect by
Jun 5, 2008BApt 12A · D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 12 STY FRONT EAST APT 12A. LOCATED AT APT 12AJul 10, 2008
Jun 5, 2008BApt 12E · D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 12 STY FRONT SOUTHEAST APT 12E. LOCATED AT APT 12EJul 10, 2008
Jun 5, 2008BApt 2A · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE BATHROOM MECHANICAL AIR VENT AT 2 STY CENTER EAST APT 2A. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 2A · D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING CERAMIC TILE WALL AT BATHROOM AT 2 STY CENTER EAST APT 2A. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 2A · D26-16.01 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS BATHROOM WASHBASIN AT 2 STY CENTER EAST APT 2A. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 2A · D26-10.01 ADM CODE PROPERLY SECURE THE LOOSE WINDOW SASHES THROUGHOUT 2 STY CENTER EAST APT 2A. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 5G · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THROUGHOUT 5 STY APT 5G. LOCATED AT APT 5GJul 10, 2008
Jun 5, 2008BD26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF VENTS FROM LAUNDRY ROOM PIERCE THROUGH WALL IN NORTHEAST FIRE PASSAGEWAY.Jul 10, 2008
Jun 5, 2008CD26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1 STY PUBLIC HALL NEAR MAILBOXES AND AT DOOR TO BOILER ROOM.Jun 11, 2008
Jun 5, 2008AD26-22.03 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER.Sep 8, 2008
Jun 5, 2008BApt 10F · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN NORTH CLOSET IN REAR SOOTH ROOM OF 10TH STY APT 10F. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 8G · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF DAMPNESS SOUTH WALL AND CEILING BATHROOM 8 STORY APT 8G SOUTHEAST. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 8G · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR SOUTH WALL AND CEILING BATHROOM 8 STORY APT 8G SOUTHEAST. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 10F · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MOISTURE PENETRATING CEILING OF CLOTHES CLOSET 10TH STY FRONT APT 10F. , SECTION '' ''Jul 10, 2008
Jun 5, 2008AApt 8F · D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GASKET OF REFRIGERATOR 8TH STY WEST APT 8F KITCHENETTE. , SECTION '' ''Sep 8, 2008
Jun 5, 2008A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WOOD & METAL FENCES INSTALLED 11TH STY TERRACE AT EAST WEST & SOUTH.Sep 8, 2008
Jun 5, 2008BApt 1B · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE INTERIOR METAL SHELF KITCHEN CABINET 1ST STY SOUTH APT 1B. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 1B · D26-10.01, 10.05 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS ENTRANCE TO 1ST STY SOUTH APT 1B. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 10C · D26-10.01 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CERAMIC TILE WALL AT BATHROOM 10 STY APT 10C. LOCATED AT APT 10CJul 10, 2008
Jun 5, 2008BApt 8E · D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF CONCEALED LEAK CEILING OF BATHROOM STY APT 8E. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 8E · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING BATHROOM 8 STY APT 8E. , SECTION '' ''Jul 10, 2008
Jun 5, 2008BApt 6E · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING BATHROOM 6 STY APT 6E. LOCATED AT APT 6EJul 10, 2008
Jun 5, 2008AD26-41.15 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING.Sep 8, 2008
Jun 5, 2008BApt 10F · D26-10.01 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND WALLS IN THE WEST CLOSET IN CENTER ROOM OF 10TH STY APT 10F. , SECTION '' ''Jul 10, 2008
Aug 16, 2007B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXPOSED WIRE AT CEILING THRU OUT 10 STY PUBLIC HALL.Sep 20, 2007
Aug 16, 2007BApt 10C · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING OF BATHROOM 10 STY WEST APT 10C. LOCATED AT APT 10CSep 20, 2007
Aug 16, 2007BApt 7D · § 27-2045, 2046 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING 7 STY APT 7D. , SECTION '' ''Sep 20, 2007

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 16, 2026, 4:57 AM ET. BBL 1013467501.