Queens · Block 249 · Lot 7501 · 11101

32-02 Queens Boulevard

8 floors · 273,020 sq ft · built 1931 · class RI · owner of record: Unavailable Owner

18open violations
$32,500ECB/OATH penalties owed
0HPD class C (immediately hazardous)
69dto Annual boiler inspection (5 boilers)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (5 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-07 (Accepted). Agency page

Dec 31, 2026
in 69 days
3 of 5 without an accepted 2026 report yet
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $57,500 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 121 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 273,020 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 190 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 190 days
Annual filing
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 2 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1165 days
Next cycle year 2029
Energy audit and retro-commissioning (2029) Likely applies
Local Law 87 · Calendar year 2029
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 249). Agency page

Dec 31, 2029
in 1165 days
Next due 2029

Open violations

ECB / OATH (5) · $32,500 owed
IssuedViolationHearingBalance
Apr 30, 2026Unknown CLASS - 2
OBSERVED MEDIUM DUTY SCAFFOLD (70+ FT IN HEIGHT) OVERLOADED WITH MATERIAL WHICH WAS UNGUARDED AND HAVING (3) WORKERS TIED-BACK TO THE SAME FRAME OF THE SCAFFOLD. CONDITIONS, AS OBSERVED, CREATED AN UNSAFE, MAKE
#39553703J
Feb 8, 2027
$2,500
Feb 2, 2026Unknown CLASS - 2
OBSERVED ALTERATION WORK IN AN OCCUPIED COMMERCIAL BUILDING. NO TENANT PROTECTION PLAN AVAILABLE DURING INSPECTION (BC 3303.10). STOP ALL WORK UNDER APPLICATION Q00894084.PROVIDE TPP
#39549895L
Dec 15, 2026
$2,500
Feb 2, 2026Site Safety CLASS - 1
OBSERVED HORIZONTAL AND VERTICAL ENLARGEMENTS UNDER CONSTRUCTION IN A COMMERCIAL BUILDING WITHOUT THE DESIGNATION OF LICENSED SUPERINTENDENT. STOP ALL WORK ENTIRE SITE.
#39549881K
Dec 15, 2026
$10,000
Feb 2, 2026Unknown CLASS - 1
OBSERVED SUPPORTED SCAFFOLD MISSING GUARDRAIL, ENDRAILS, TOEBOARDS, CREATING FALL HAZARD (BC 3314.1). STOP ALL USE OF SUPPORTED SCAFFOLD AND NO WORK ON ELEVATOR SHAFT.MAINTAIN SCAFFOLD
#39549887L
Dec 15, 2026
$5,000
Oct 1, 2024Construction CLASS - 1
FAILURE TO SUBMIT THE REQUIRED PARKING STRUCTURE INITIAL OBSERVATION REPORT FOR AN EXISTING PARKING STRUCTURE DOCUMENTING THE CONDITIONS OF PSID#Q0002296 BY THE AUGUST 1,2024 DEADLINE.TO DATE,THE DEPARTMENT HAS
#37029877X
Mar 4, 2025
DEFAULT
$12,500
DOB (8)
IssuedViolationStatus
Jun 23, 2024FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2023)
#00584
DOB VIOLATION - ACTIVE
Feb 22, 2024FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00355
DOB VIOLATION - ACTIVE
Dec 1, 2023FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2301528
DOB VIOLATION - ACTIVE
Nov 2, 2023FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00443
DOB VIOLATION - ACTIVE
Aug 2, 2023FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#00609
DOB VIOLATION - ACTIVE
Jun 22, 2023FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2022)
#00023
DOB VIOLATION - ACTIVE
May 2, 2023FAILURE TO BENCHMARK
FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
#01200
DOB VIOLATION - ACTIVE
Aug 21, 2022FAILURE TO SUBMIT EER
FAILURE TO SUBMIT AN EER PER AD. CODE SEC. 28-308.4 - MULTIPLE YEARS (2021)
#00395
DOB VIOLATION - ACTIVE
DOB NOW Safety (9)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Jun 23, 2024Retro-Commissioning - LL87 FTF-EN-EARCX
Active
Feb 22, 2024Benchmarking - LL84 FTF-EN-BENCH
Active
Dec 1, 2023Energy Grade - LL33 FTP-EN-EGRDEA
Active
Nov 2, 2023Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 2, 2023Benchmarking - LL84 FTF-EN-BENCH
Active
Jun 22, 2023Retro-Commissioning - LL87 FTF-EN-EARCX
Active
May 2, 2023Benchmarking - LL84 FTF-EN-BENCH
Active
Aug 21, 2022Retro-Commissioning - LL87 FTF-EN-EARCX
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 4:32 PM ET. BBL 4002497501.

Look up another building