7 floors · 124 apartments · 35,427 sq ft · built 1906 · class D3 · owner of record: Clover Housing Development Fund Corporat Ion
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 45 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 45 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 61 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 35,427 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 166 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 166 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 289 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $12,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 828 days | Filing window not open yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1141 days | Next cycle year 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-01-28 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 31, 2026 | Elevators CLASS - 1 CLASS 1(CU):FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, DOOR ZONE RESTRICTOR INOPERATIVE,REPAIR AND TEST.CLASS 2:REMOVE ALL OLD #39202484Y | Nov 5, 2026 IN VIOLATION | $1,250 |
| Aug 31, 2026 | Elevators CLASS - 2 CLASS 2 ITEMS: IN-CAR EMERGENCY COMMUNICATION INOPERATIVE, IN VIOLATION OF ASME A17.1 2.27.1.1, AS MODIFIED BY NYC BC APPENDIX K. CLEAN TOP OF CAR AND PROPERLY SECURE OR REMOVE ITEMS NOT BELONGING ON TOP OF CAR #39202399J | Dec 17, 2026 PENDING | $625 |
| Dec 19, 2017 | Elevators CLASS - 2 97X10)RETURN ELEVATOR TO SERVICE. #38257366P | Feb 8, 2018 STIPULATION/IN-VIO | $0 |
| Jun 20, 2017 | Local Law CLASS - 2 FAILURE TO FILE ANNUAL CERTIFICATION THAT COOLING TOWER 1000004196 HASBEEN INSPECTED,TESTED & DISINFECTED & THAT A MAINTENANCE PLAN HAS BEENDEVELOPED AND IMPLEMENTED,BY NOVEMBER,1,2016.REM:FILE ANNUAL CERTIFICA #37002874K | Nov 30, 2017 ADMIT/IN-VIO | $0 |
| Jun 5, 2017 | Elevators CLASS - 2 02X10,17D06,45I10,68B07,68M07,71X10. 02X-2WAY COMMUNICATION INOPERAB LE; 17D-PLAY IN SILL ON 3RD FLR (CHECK GIBS); 45I-REPAIR LOCK FOR GOV ERNOR ACCESS-DOOR; 68-UPDATE LOG; 68M-PROVIDE BRAKE MAINTENANCE TAG #38255482N | Jul 20, 2017 DEFAULT | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 2, 2021 | ELEVATOR #9028/710026 | DOB VIOLATION - ACTIVE |
| May 8, 2013 | ELEVATOR #9027/446650 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 2, 2026 | Elevators FTF-VT-PER-CO Violation Issued-Failure To File 2025 Periodic Inspection Report | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 7) | Active |
| Apr 30, 2019 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Oct 5, 2026 | C | Apt B304 · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT B304, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''WEST'' | Oct 19, 2026 |
| Aug 31, 2026 | B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD PANEL AT DOOR AT ENTRANCE AT SUITE ''B'' AT COMMUNITY BATHROOM, 3rd STORY | Oct 5, 2026 |
| Jul 24, 2026 | A | Apt C204 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM AT SOUTHWALL IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM C204, 2nd STORY, 1st B-ROOM FROM WEST AT NORTH | Oct 27, 2026 |
| Jul 24, 2026 | C | Apt C204 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT B-ROOM C204, 2nd STORY | Aug 19, 2026 |
| Jul 24, 2026 | A | Apt C204 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM C204, 2nd STORY, 1st B-ROOM FROM WEST AT NORTH | Oct 27, 2026 |
| Jul 24, 2026 | A | Apt C204 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM C204, 2nd STORY, 1st B-ROOM FROM WEST AT NORTH | Oct 27, 2026 |
| Jul 22, 2026 | A | Apt C201 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM C201, 2nd STORY, 1st B-ROOM FROM WEST AT NORTH | Oct 25, 2026 |
| Jul 22, 2026 | A | Apt C201 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM C201, 2nd STORY, 1st B-ROOM FROM WEST AT NORTH | Oct 25, 2026 |
| Jun 26, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT FIRE PUMP ROOM AT CELLAR | Jul 31, 2026 |
| Jun 26, 2026 | B | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET WATER AND GAS ROOM AT CELLAR | Jul 31, 2026 |
| Apr 3, 2026 | C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE 1st ROOM FROM EAST LOCATED AT SRO, 4th STORY, 1st SINGLE ROOM OCCUPANCY FROM NORTH AT EAST | Apr 29, 2026 |
| Feb 11, 2026 | A | Apt D601 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING AND ALL WALLS IN THE ROOM LOCATED AT B-ROOM D601, 6th STORY, 1st B-ROOM FROM WEST AT NORTH , SECTION ''D'', 1st FROM NORTH AT NORTHEAST | May 17, 2026 |
| Jan 26, 2026 | C | Apt D103 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ROOM LOCATED AT B-ROOM D103, 1st STORY, 1st B-ROOM FROM EAST AT SOUTH , SECTION ''SUITE D'' | Feb 21, 2026 |
| Jan 26, 2026 | B | Apt C304 · § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE FLOOR IN THE ROOM LOCATED AT B-ROOM C304, 3rd STORY, 1st B-ROOM FROM SOUTH AT WEST , SECTION ''SUITE C'' | Mar 2, 2026 |
| Jan 2, 2026 | C | Apt B601 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT B-ROOM B601, 6th STORY, 1st B-ROOM FROM EAST AT SOUTH , SECTION ''B'' | Jan 28, 2026 |
| Jan 2, 2026 | C | Apt B601 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES LOCATED AT B-ROOM B601, 6th STORY, 1st B-ROOM FROM EAST AT SOUTH , SECTION ''B'' | Jan 1, 2026 |
| Sep 30, 2025 | C | Apt D103 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT B-ROOM D103, 1st STORY, 1st B-ROOM FROM EAST AT SOUTH , SECTION ''D'' | Oct 26, 2025 |
| Sep 19, 2025 | B | § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUSRE FEET AT CEILING AT 2nd COMMUNITY BATHROOM FROM NORTH, 2nd STORY, SECTION ''C'' ORIGINAL VIOLATION 17908601 ISSUED 21-MAY-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3a(3)(a) o | Oct 24, 2025 |
| Jul 17, 2025 | B | Apt B304 · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BELL AND BUZZER SYSTEM FROM BUILDING FRONT ENTRANCE TO RECEIVING PANEL AT EAST WALL IN THE ENTIRE APARTMENT LOCATED AT APT B304, 3rd STORY | Aug 21, 2025 |
| Mar 19, 2025 | A | Apt D601 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD CABINET ABOVE THE SINK AT NORTH WALL. IN THE 1st ROOM FROM NORTH LOCATED AT APT D601, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 22, 2025 |
| Mar 19, 2025 | A | Apt D601 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND ALL WALLS. IN THE 1st ROOM FROM NORTH LOCATED AT APT D601, 6th STORY, 1st APARTMENT FROM NORTH AT EAST | Jun 22, 2025 |
| Feb 26, 2025 | A | Apt C304 · § 27-2011 ADM CODE CLEANSE TO THE SATISFACTION OF THIS DEPARTMENT THE EXCESSIVE AMOUNT OF STORAGE, HOUSE HOLD ITEMS, CLOUTHS. TENANT FAILED TO KEEP THE ROOM DESCENT AND SANITARY. THE PROVISIONS OF H.U.D (UNSANITARY CONDITIONS) IN THE 2nd ROOM FROM NORTH AT WEST LOCATED AT B-ROOM C304, 3rd STORY, 1st | Jun 1, 2025 |
| Feb 26, 2025 | A | Apt D103 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL WALLS AND CEILING, IN THE ROOM LOCATED AT B-ROOM D103, 1st STORY, 1st B-ROOM FROM EAST AT SOUTH , SECTION ''SUITE D'' | Jun 1, 2025 |
| Date | Source | What | Now |
|---|---|---|---|
| Oct 5, 2026 | HPD C | § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT DOOR IN THE ENTRANCE LOCATED AT APT B304, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION ''WEST'' | Open |
| Oct 2, 2026 | DOB Safety | Elevators: Violation Issued-Failure To File 2025 Periodic Inspection Report | Open |
| Sep 18, 2026 | HPD B | § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WATER LEAK AT BACK FLOW FIRE PUMP ROOM | Closed |
| Aug 31, 2026 | ECB | Elevators: CLASS 1(CU):FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER PASSENGER ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, DOOR ZONE RESTRICTOR INOPERATIVE,REPAIR AND TEST.CLASS 2:REMOVE ALL OLD | Open |
| Aug 31, 2026 | ECB | Elevators: CLASS 2 ITEMS: IN-CAR EMERGENCY COMMUNICATION INOPERATIVE, IN VIOLATION OF ASME A17.1 2.27.1.1, AS MODIFIED BY NYC BC APPENDIX K. CLEAN TOP OF CAR AND PROPERLY SECURE OR REMOVE ITEMS NOT BELONGING ON TOP OF CAR | Open |
| Aug 31, 2026 | HPD B | § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD PANEL AT DOOR AT ENTRANCE AT SUITE ''B'' AT COMMUNITY BATHROOM, 3rd STORY | Open |
| Jul 24, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM AT SOUTHWALL IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM C204, 2nd STORY, 1st B-ROOM FROM WEST AT NORTH | Open |
| Jul 24, 2026 | HPD C | HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES LOCATED AT B-ROOM C204, 2nd STORY | Open |
| Jul 24, 2026 | HPD A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM C204, 2nd STORY, 1st B-ROOM FROM WEST AT NORTH | Open |
| Jul 24, 2026 | HPD A | § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LIGHT FIXTURE AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM C204, 2nd STORY, 1st B-ROOM FROM WEST AT NORTH | Open |
| Jul 22, 2026 | HPD A | § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT NORTH WALL IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM C201, 2nd STORY, 1st B-ROOM FROM WEST AT NORTH | Open |
| Jul 22, 2026 | HPD A | § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT B-ROOM C201, 2nd STORY, 1st B-ROOM FROM WEST AT NORTH | Open |