5 floors · 60 apartments · 30,048 sq ft · built 1920 · class C1 · owner of record: 88th Street Associates #1, Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 44 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 44 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 60 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 30,048 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 165 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 165 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 288 days | Registered through 2027-09-01 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-29 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| May 15, 2014 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT #04181 | DOB VIOLATION - ACTIVE |
| Aug 29, 1995 | LOCAL LAW 62/91 - BOILERS #09846 | DOB VIOLATION - ACTIVE |
| Mar 18, 1994 | LOCAL LAW 62/91 - BOILERS #13285 | DOB VIOLATION - ACTIVE |
| Mar 18, 1993 | LOCAL LAW 62/91 - BOILERS #13285 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| May 15, 2014 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2012 INSPECTION REPORT | Active |
| Aug 29, 1995 | Boiler LL6291 | Active |
| Mar 18, 1994 | Boiler LL6291 | Active |
| Mar 18, 1993 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Nov 19, 2021 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES FLOWER POTS AT 5TH STORY BALCONY AT BUILDING FRONT | Dec 24, 2021 |
| Feb 25, 2019 | A | Apt 17 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | May 31, 2019 |
| Feb 25, 2019 | B | Apt 17 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING AND EAST WALL IN THE KITCHEN LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Apr 1, 2019 |
| Feb 22, 2019 | A | Apt 17 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | May 28, 2019 |
| Feb 22, 2019 | B | Apt 17 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING. IN THE 3rd ROOM FROM NORTH LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Mar 29, 2019 |
| Dec 3, 2018 | C | Apt 17 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE KITCHEN LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Dec 11, 2018 |
| Dec 3, 2018 | B | Apt 17 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE KITCHEN LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jan 7, 2019 |
| Dec 3, 2018 | C | Apt 17 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Dec 11, 2018 |
| Dec 3, 2018 | B | Apt 17 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR ALL WALLS IN THE 1st ROOM FROM NORTH LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jan 7, 2019 |
| Dec 3, 2018 | B | Apt 17 · § 27-2005, 2007 ADM CODE ARRANGE AND MAKE SELF-CLOSING THE DOORS .. IN THE ENTRANCE LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jan 7, 2019 |
| Dec 3, 2018 | B | Apt 17 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jan 7, 2019 |
| Dec 3, 2018 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME NOT ACCESIBLE AT PUBLIC HALL, 1st STORY | Mar 8, 2019 |
| Dec 3, 2018 | C | Apt 17 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 1st ROOM FROM NORTH LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Dec 11, 2018 |
| Dec 3, 2018 | B | Apt 17 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jan 7, 2019 |
| Dec 3, 2018 | B | Apt 17 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jan 7, 2019 |
| Dec 3, 2018 | B | Apt 17 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jan 7, 2019 |
| Dec 3, 2018 | C | Apt 17 · § 27-2005 ADM CODE REPAIR THE ROOF SO THAT IT WILL NOT LEAK AT CEILING IN THE KITCHEN LOCATED AT APT 17, 5th STORY, 2nd APARTMENT FROM NORTH AT EAST | Dec 11, 2018 |
| Apr 27, 2018 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY | Jul 31, 2018 |
| Apr 27, 2018 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX - MISSING AT PUBLIC HALL, 1st STORY | Jul 31, 2018 |
| Apr 27, 2018 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF MICROWAVE AT 4TH STORY BALCONY AT FIRE ESCAPE AT BUILDING FRONT | Jun 1, 2018 |
| Apr 27, 2018 | A | § 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY | Jul 31, 2018 |
| Nov 11, 2015 | A | SECTION 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME READILY ACCESSIBLE FOR SIGNATURE, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR AT LOBBY 1ST STORY , 1st STORY | Feb 14, 2016 |
| Oct 24, 2011 | B | SECTION 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE AT PUBLIC HALL, 1st STORY | Nov 28, 2011 |
| Oct 24, 2011 | B | SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE GARBAGE IN THE PUBLIC HALL , 1st STORY | Nov 28, 2011 |
| Dec 29, 2000 | C | Apt 20 · SECTION 27-2056.5 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE ON WOOD TRIM, DOORS, OR WINDOWS - USING EXCLUSIVE INTERIM CONTROLS, WHICH INCLUDE A SURFACE DUST TEST IN ACCORDANCE WITH STATUTE. NORTHEAST WINDOW FRAME AT WEST, NOR | Jan 29, 2001 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 7:49 PM ET. BBL 1015510012.