21 floors · 410,334 sq ft · built 1920 · class O4 · owner of record: 333 Seventh Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 65 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10A) Applies Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $2,486,800 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2027 in 117 days | No Cycle 10 report on record yet |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 410,334 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 186 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 186 days | Annual filing |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1161 days | Next cycle year 2029 |
| Energy audit and retro-commissioning (2034) Likely applies Local Law 87 · Calendar year 2034 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 804). Agency page | Dec 31, 2034 in 2987 days | Next due 2034 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-09-17 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| May 8, 2024 | Unknown CLASS - 1 DURING INSPECTION, ELECTRICAL COMPONENTS SUCH AS EQUIPMENT, APPARATUS,MATERIALS, DEVICES, APPLIANCES, OR WIRING WERE FOUND TO BE UNAPPROVED,UNSAFE, OR UNSUITABLE FOR USE. IT WAS NOTED THAT PRESENTING A HAZARDOU #35667454H | Oct 24, 2024 IN VIOLATION | $1,600 |
| Dec 9, 2022 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#901857.REMEDY:SUBMIT ACCEPTABLE REQUIRE #37024558X | Mar 2, 2023 DEFAULT | $3,125 |
| Dec 15, 2021 | Construction CLASS - 2 BUILDING ALTERED AND OCCUPIED WITHOUT A VALID COFO. NOTED: BUILDING WAS ALTERED UNDER ALT-1 APPLICATION # 110427949 AND TEMPORARY COFO # 110427949T22 EXPIRED ON 02/23/2021., OBTAIN A VALID C OF O OR DISCONTINUE #39052887H | Jun 9, 2022 IN VIOLATION | $0 |
| Oct 23, 2018 | Construction CLASS - 1 FAILURE TO PROVIDE AND TAKE ADEQUATE SAFETY MEASURES WHERE REQUIRED TOSECURE AND PROTECT PUBLIC SAFETY FROM DOCUMENTED UNSAFE FILING OF BUILDING FACADE AS PER 1RCNY.103-04. *UNSAFE FCADE FILING FILED BY PE/RA ¦ #35365147Y | Jun 6, 2019 IN VIOLATION | $9,900 |
| Issued | Violation | Status |
|---|---|---|
| Nov 25, 2025 | CONSTRUCTION STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION OBSERVED WINDOW REPLACEMENT WORK IN PROGRESS NO OVERHEAD PROTECTION IN PLACE. #25-02842 | DOB VIOLATION - ACTIVE |
| Jul 2, 2001 | CONSTRUCTION #05M01 | VIOLATION WORK WITHOUT PERMIT - ACTIVE |
None open.
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 27, 2026, 1:33 AM ET. BBL 1008040001.