Brooklyn · Block 4137 · Lot 56 · 11208

3167 Atlantic Avenue

1 floors · 10,385 sq ft · built 1924 · class G1 · owner of record: 3167 Atlantic, Llc

7open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
1159dto Gas piping inspection (2029 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 63 days
Keep the report on file (not filed with DOB)
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1159 days
Next cycle year 2029

Open violations

ECB / OATH (2)
IssuedViolationHearingBalance
May 14, 2025Unknown CLASS - 2
FAILURE TO MAINTAIN PARKING STRUCTURE.NOTE:AT THE TIME OF INSPECTION OBSERVED AT EXP#1 AND 4(NORWOOD AVE AND ATLANTIC AVE)STEPED CRACKS BRICKS MASONRY AT EXP#3 CRACKS BRICKS.REM:COMPLY WITH CODE.
#35693803X
Jul 23, 2025
ADMIT/IN-VIO
$0
Jan 28, 2015Construction CLASS - 2
28-104.7.11 FAILURE TO COMPLY WITH A COMMISSIONER'S ORDER.THE BLDG IS A WAREHOUSE-TYPE STRUCTURE WITH A WOOD BOWSTRING TRUSS ROOF.THE RESPONDENT DID NOT PROVIDE AN ENGINEER'S REPORT AS REQUIRED BY COMMISSIONER'
#35153639X
Mar 23, 2015
STIPULATION/IN-VIO
$0
DOB (3)
IssuedViolationStatus
Aug 1, 2014CONSTRUCTION
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. THE BLDG HAS A WOOD BOW- STRING TRUSS ROOF. THE DEPARTMENT SERVED YOU A CURABLE COMM. ORDER (NOTICE OF VIOLATION) ON 5/05/2014 TO PRODUCE AN ENGR REPORT ON YOUR BLDG. NO ENGR REPORT HAS BEEN RECEIVED. COMPLY PER THE COMMISIONER'S ORDER
#FEU0505WW
DOB VIOLATION - ACTIVE
May 5, 2014CONSTRUCTION
245 NORWOOD AV:1 STORY OCCUPIED PARKING GARAGE/WOOD BOWSTRING TRUSS ROOF.WITHIN 60DAYS OF VIO,OWNER TO ENGAGE NYS LIC PE EXPRNC'D/WOODTRUS TO PROBE&EVALUATE STRUCTR'L SOUNDNESS OF BOWSTRING USING FIELD VERIFICATIONS,CALCULATIONS,PROBES,ETC. EA.TRUSS&BEARINGS EVAL'D. ANY STRUCTURAL DEFICIENCIES SHORE
#FEU30502JH
DOB VIOLATION - ACTIVE
Jan 15, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01420
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Sep 23, 2026Parking Structures FTF-PS-INITL
Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13
Active
Jan 15, 2014AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Sep 23, 2026DOB SafetyParking Structures: Failure to file parking structures compliance report by 12/31/2025 as required per 1 RCNY 103-13Open

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 29, 2026, 9:55 PM ET. BBL 3041370056.