Manhattan · Block 1044 · Lot 24 · 10019

315 West 53 Street

3 floors · 2,430 sq ft · built 1920 · class O2 · owner of record: Ada B Llc

16open violations
$96,370ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2023-12-28 (Accepted). Agency page

Dec 31, 2026
in 47 days
1 of 1 without an accepted 2026 report yet

Open violations

ECB / OATH (14) · $96,370 owed
IssuedViolationHearingBalance
Jun 4, 2026Site Safety CLASS - 1
AT THE TIME OF MY INSPECTION OBSERVED CS FAILED TO PERFORM DUTIES PER CODE, NO PLANS WAS PROVIDED UPON REQUEST OF COMPETENT PERSON INADEQUATE ERECTION OF STEEL BEAM ABOVE WINDOW PANEL WITHOUT APPROVE DESIGN DRA
#39555072L
Mar 8, 2027
PENDING
$10,000
Jun 4, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION OBSERVED COLD FORM STEEL WITHOUT BLOCKING OR STRAP BRIDGING ON FLOORS 2,3,4,5. NO DESIGN DRAWINGS FOR COLD FORM STEEL CONNECTIONS WITH STEEL BEAM STRUCTURE ON 3RD FL. 28-105.12.2 UP
#39555068Z
Aug 13, 2026
DEFAULT
$12,500
Jun 4, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION OBSERVED STEEL BEAM ABOVE WINDOW FRAME INSTALLED WITHOUT DESIGN DRAWINGS@2ND LEVEL, NO DETAILS FOR STEEL BEAM ATTACH TO WOOD JOISTS, STEEL BEAM WITH INADEQUATE SPLICE PLATES @LEVEL
#39555067R
Aug 13, 2026
DEFAULT
$12,500
Jun 4, 2026Construction CLASS - 1
AT THE TIME OF MY INSPECTION OBSERVED INADEQUATE SHORING IN CELLAR LEVEL. UPON REQUEST NO DETAILS FOR INADEQUATE SHORING WAS PROVIDE. 28-105.12.2 SHORING WORK DOES NOT CONFORM WITH APPROVE DRAWINGS UNDER PERMIT
#39555055J
Aug 13, 2026
DEFAULT
$12,500
Apr 16, 2026Unknown CLASS - 2
BC 3305.3.3.3: AT THE TIME OF INSPECTION OF A 5-STORY BUILDING, COLD-FORMED STEEL WORK WAS OBSERVED. UPON REQUEST, NO SPECIAL INSPECTION REPORT WAS PROVIDED. STOP ALL STRUCTURAL WORK AND PROVIDE REQUIRED SPECIA
#39553154X
Jun 25, 2026
DEFAULT
$10,000
Apr 16, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION OF A 5-STORY BUILDING, A SIDEWALK SHED WAS IN PLACE CONTRARY TO APPROVED DRAWINGS. AT EXP# 2, CATCH-ALL INSTALLED WITHOUT REQUIRED PLANKING AND PLYWOOD, COMPROMISING STABILITY AND CREA
#39553153Y
Jun 25, 2026
DEFAULT
$6,250
Jan 30, 2026Unknown CLASS - 2
3314.3.4 AT TIME OF INSPECTION OF A 5 STORIES BUILDING UNDER STRUCTURAL PERMIT I OBSERVED SUPPORTED SCAFFOLD INSTALLED ON TOP OF SIDEWALK SHED, UPON REQUEST FOR LOAD IMPOSED LETTER FROM THE REGISTERED PROFESS
#39549679R
Dec 3, 2026
$2,500
Jul 23, 2025Construction CLASS - 2
DURING MY INSPECTION OF AN ACTIVE ALT SITE, I REVIEWED THE SITE HISTORY. I OBSERVED THAT THE PERMIT HOLDER HAS FAILED TO FILE AN ACCEPTED CERTIFICATE OF CORRECTION WITH THE DEPARTMENT REF- 39540770R ISSUED ON 5
#39542704H
Oct 2, 2025
DEFAULT
$3,125
Jul 23, 2025Construction CLASS - 2
DURING MY INSPECTION OF AN ACTIVE ALT SITE, I REVIEWED THE SITE HISTORY. I OBSERVED THAT THE PERMIT HOLDER HAS FAILED TO FILE AN ACCEPTED CERTIFICATE OF CORRECTION WITH THE DEPARTMENT REF- 39540771Z ISSUED ON 5
#39542705J
Oct 2, 2025
DEFAULT
$3,125
May 28, 2025Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED ACTIVE UNDERPINNING ACTIVITIES. EXCAVATION WORK IS SUBSTANTIALLY COMPLETED. UPON FURTHER RESEARCH FOUND OUT NO REQUIRE EARTH WORK NOTIFICATION PRIOR TO COMMENCEMENT OR EARTH WORK
#39540771Z
Oct 1, 2026
DEFAULT
$2,530
May 28, 2025Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED ACTIVE UNDERPINNING ACTIVITIES. UPON INSPECTING APPROVED PLANS NOTICE WORK OUT OF SEQUENCE. AS PER DRAWINGS IT SHOWS RAKERS TO BE INSTALLED PRIOR THE GLOBAL EXCAVATION. ON PAGE 4
#39540770R
Oct 1, 2026
DEFAULT
$2,530
May 27, 2025Construction CLASS - 2
AT TIME OF INSPECTION OBSERVED ACTIVE UNDERPINNING WORK ON SITE. UPON REQUESTING THE FOLLOWING DOCUMENTS SOE/UNDERPINNING DRAWINGS, ADEQUATE SITE SAFETY PLAN (NOT SIGN), SWS DRAWINGS, LETTER OF INSTALLATION FOR
#39540684K
Oct 1, 2026
DEFAULT
$1,280
May 27, 2025Unknown CLASS - 1
AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION ACTIVITIES. UPON REQUESTING PRE-SHIFTS CP PROVIDED A FOLDER OF INADEQUATE PRE-SHIFTS. NO INFORMATION OF DAILY ACTIVITIES/TASK AND NO NOTES ABOUT SAFETY CONCERN
#39540685M
Oct 1, 2026
DEFAULT
$5,030
May 27, 2025Site Safety CLASS - 1
AT TIME OF INSPECTION OBSERVED ACTIVE CONSTRUCTION SITE CURRENTLY DOING UNDERPINNING. SAFETY VIOLATING CONDITIONS FOUND DURING INSPECTION. UPON REQUESTING DAILY LOG FOR CONSTRUCTION SUPER, CP PROVIDE LOG THAT W
#39540683Z
Jun 11, 2026
DEFAULT
$12,500
DOB (3)
IssuedViolationStatus
Nov 14, 2025LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
#02955
DOB VIOLATION - ACTIVE
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#14796
DOB VIOLATION - ACTIVE
Nov 8, 2019LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
#01897
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Jul 8, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 8, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 8, 2026AEUHAZ FTC-AEU-HAZ
Active
Jul 8, 2026AEUHAZ FTC-AEU-HAZ
Active
Nov 14, 2025Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 8, 2019Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 10:58 PM ET. BBL 1010440024.

Look up another building