Bronx · Block 2344 · Lot 27 · 10451

315 Grand Concourse

14 floors · 122 apartments · 100,061 sq ft · built 2024 · class D1 · owner of record: Walton Street Gc Developments Llc

1open violations
$10,084ECB/OATH penalties owed
0HPD class C (immediately hazardous)
69dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 69 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 85 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 121 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 100,061 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 190 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 190 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 313 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 800 days
Next cycle year 2028
Energy audit and retro-commissioning (2034) Likely applies
Local Law 87 · Calendar year 2034
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 2344). Agency page

Dec 31, 2034
in 2991 days
Next due 2034

Open violations

ECB / OATH (3) · $10,084 owed
IssuedViolationHearingBalance
Feb 26, 2026Unknown CLASS - 2
DURING MY INSPECTION OF A 14-STORY NB, NO ONGOING CONSTRUCTION ACTIVITY. ACTIVE PERMIT# X00673520, WITH A BUILDING FOOTPRINT (SQ. FT.)10621. NO CERTIFICATE OF OCCUPANCY HAS BEEN ISSUED AFTER WALKING THE PERIME
#39550954K
Oct 23, 2026
$2,500
Jun 20, 2025Construction CLASS - 1
OBSERVED SIDEWALK SHED @ EXPO 1 & SUPPORTED SCAFFOLD UP TO THE 10TH FLOOR @ EXPO 3 STILL IN PLACE. GENERAL CONTRACTOR FILED A FORM SSR-X00673520-I1-01, FOR THE RELEASE OF CS CHARLIE HUNG 027800 CONTAINING A FAL
#39541583X
Mar 19, 2026
IN VIOLATION
$5,084
May 24, 2025Unknown CLASS - 2
3303.3 WATCHPERSON. I OBSERVED 14-STORY PROPOSED NEW BUILDING, APPROX.29488 SQUARE FEET. SITE CLOSED AND THERE WERE NO CONSTRUCTION ACTIVITY.UPON SHOUTING AT PERIMETER AND BANGING ON FENCE AND DOOR TO ALERT WAT
#39540637H
Mar 18, 2027
$2,500
DOB (1)
IssuedViolationStatus
Nov 10, 2009ELEVATOR

#9027/317632
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 7:50 PM ET. BBL 2023440027.

Look up another building