Manhattan · Block 1351 · Lot 7 · 10022

315 East 58 Street

4 floors · 10 apartments · 8,630 sq ft · built 1940 · class C5 · owner of record: 315 E58 Bh Llc

8open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
43dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 43 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 43 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-11-25 (Accepted). Agency page

Dec 31, 2026
in 43 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 59 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 287 days
Registered through 2027-09-01

Open violations

ECB / OATH (0)

None open.

DOB (2)
IssuedViolationStatus
May 10, 2024CONSTRUCTION
FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.FACADE DISREPAIR&VARIOUS CRACKS THROUGHOUT EXP1,2,&4.NEW STEEL FRAMING&POSTS INSTALLED ON ROOF TO SPPORT THE NEW HVAC.OWNRS PE TO VERIFT EXSTNG ROOF JOISTS CAPACITY OWNR TO IMMED RTAIN NYSPE TO EVAL THE ENT BLDG,DETERMINE THE STRCTRL STBILITY
#FEU10601ZT
DOB VIOLATION - ACTIVE
Aug 26, 2007CONSTRUCTION

#0601CH
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (6) · C 0 · B 6 · A 0
IssuedClassViolationCorrect by
Jun 1, 2026BApt 1A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER WINDOW SASH 1ST WINDOW FROM EAST AT SOUTH WALL. IN THE 4th ROOM FROM NORTH LOCATED AT BSMT-APT 1A, 1st BSMT-APT FROM NORTH AT EASTJul 6, 2026
Jun 1, 2026BApt 1A · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT SOUTH WALL IN THE 4th ROOM FROM NORTH LOCATED AT BSMT-APT 1A, 1st BSMT-APT FROM NORTH AT EASTJul 6, 2026
Jun 1, 2026BApt 1A · § 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1A, 1st BSMT-APT FROM NORTH AT EASTJul 6, 2026
Jun 1, 2026BApt 1A · § 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT BSMT-APT 1A, 1st BSMT-APT FROM NORTH AT EASTJul 6, 2026
Jun 1, 2026BApt 1A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE EAST AND SOUTH WALLS. IN THE 3rd ROOM FROM NORTH LOCATED AT BSMT-APT 1A, 1st BSMT-APT FROM NORTH AT EASTJul 6, 2026
Jun 1, 2026BApt 1A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WINDOW SASH COUTER BALANCE AT WINDOW AT NORTH WALL IN THE 3rd ROOM FROM NORTH LOCATED AT BSMT-APT 1A, 1st BSMT-APT FROM NORTH AT EASTJul 6, 2026

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 8:06 AM ET. BBL 1013510007.