2 floors · 2,620 sq ft · built 1920 · class W9 · owner of record: Colony South-Brooklyn Houses, Inc.
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 68 days | Keep the report on file (not filed with DOB) |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1164 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-03-04 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 15, 2025 | Boilers CLASS - 2 FOUND WEIL MCLAIN (MODEL# EGH 55 ) GAS FIRED BOILER NOT REGISTERED CORRECT VIOLATING CONDITION SUBMIT CERTIFICATE OF CORRECTION #39157234L | Oct 22, 2025 IN VIOLATION | $0 |
| Jun 8, 2022 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING.NOTED:AT TIME OF INSPECTION OBSERVED SMOKE DOOR BETWEEN CLASSROOM 3 & 4 & EXTERIOR DOOR(EXIT)AT CLASSROOM NOT CLOSING PROPERLY CREATING HAZARDOUS CONDITION IN EVENT OF FIRE.REMEDY:REP #35663159R | Nov 2, 2022 DEFAULT | $0 |
| Jun 8, 2022 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER:NO FIRESTOPPING PER BC 712.3;27-345.NOTED:AT TIME OF INSPECTION,OBSERVED THAT THE CELLAR LEVEL ELECTRICAL AND GAS METER ROOM HAVE LARGE HOLES IN THE CEILING #35663160Y | Nov 2, 2022 DEFAULT | $0 |
| Jul 15, 2020 | Boilers CLASS - 2 FOUND WEIL MCLAIN BOILER MODEL CGM-4-PI UNREGISTERED AND OPERATING. 83,000 BTU. REGISTER BOILER AND CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION #39025451N | Jul 7, 2021 DEFAULT | $0 |
| Jul 15, 2020 | Boilers CLASS - 2 FOUND WEIL MCLAIN BOILER MODEL EG-55 UNREGISTERED AND OPERATING. 200,000 BTU. REGISTER BOILER AND CORRECT ALL VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION #39025452P | Nov 18, 2020 DEFAULT | $0 |
| Mar 10, 2020 | Boilers CLASS - 2 B 254-36 FOUND WEIL MCLAIN SERIAL# 550201400C NOT REGISTERED, REGISTER THE BOILER AND SUBMIT A CERTIFICATE OF CORRECTION #39019328R | Jul 15, 2020 DEFAULT | $0 |
| Jul 29, 2019 | Construction CLASS - 2 FAILURE TO MAINTAIN BUIDING IN CODE COMPLAINT AMNNER NOTED AT CLASSROOM #3 EXIT PASSWAY TO 3RD AVENUE WAL HAS SPALLING PAINT IN VARIOUS AREAS THE EXIT DOOR ITSELF ALSO HAS SPALLING SHEET METAL ABOVE THE PANIC A #35434044H | Dec 2, 2019 DEFAULT | $0 |
| Jun 19, 2018 | Boilers CLASS - 2 WEIL MCLAIN CGM4 105,000. 50A-CANNOT ISOLATE CONTROLS; 50D-MISSING INSULATION; 50C-WRONG FLUE PIPE GAUGE; 50D-NOT INTERLOCKED DAYCARE CENTER #32096074K | Aug 30, 2018 IN VIOLATION | $0 |
| Jun 9, 2018 | Boilers CLASS - 2 38,50A-50C. WEIL MCLAIN EG50 175,000 50A-NO C/O DETECTOR INTERLOCKED(DAYCARE CENTER); 50B-WRONG GAUGE FLUEPIPE; 50C-MISSING INSULATION 50C-PVC IN BOILER ROOM. #32096073Z | Aug 30, 2018 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 13, 2004 | LOCAL LAW 62/91 - BOILERS #17514 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #12997 | DOB VIOLATION - ACTIVE |
| Mar 19, 2003 | LOCAL LAW 62/91 - BOILERS #12998 | DOB VIOLATION - ACTIVE |
| Feb 27, 2001 | LOCAL LAW 62/91 - BOILERS #13188 | DOB VIOLATION - ACTIVE |
| Feb 27, 2001 | LOCAL LAW 62/91 - BOILERS #13189 | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #17719 | DOB VIOLATION - ACTIVE |
| Feb 10, 1997 | LOCAL LAW 62/91 - BOILERS #17720 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #29633 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #29634 | DOB VIOLATION - ACTIVE |
| Aug 16, 1993 | LOCAL LAW 62/91 - BOILERS #29635 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Sep 18, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle B (premises is in Community District 7) | Active |
| Feb 13, 2004 | Boiler LL6291 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Mar 19, 2003 | Boiler LL6291 | Active |
| Feb 27, 2001 | Boiler LL6291 | Active |
| Feb 27, 2001 | Boiler LL6291 | Active |
| Feb 10, 1997 | Boiler LL6291 | Active |
| Feb 10, 1997 | Boiler LL6291 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 24, 2026, 6:49 PM ET. BBL 3007370014.