Manhattan · Block 1944 · Lot 23 · 10026

313 West 117 Street

6 floors · 10 apartments · 11,910 sq ft · built 2016 · class C1 · owner of record: 313 Harlem Llc

3open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 10 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 778 days
Next cycle year 2028

Open violations

ECB / OATH (3)
IssuedViolationHearingBalance
Jul 11, 2016Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY. AT TIME OF INSPECTIONPORT A POTTIE DIFFICULT TO ACCESS. WORKER HAVE TO CLIMB OVER PERMANENTOBSTACLES. FALLING AND TRIPPING HAZARD IN ORDER TO ACCESS RESTROOM.STO
#35195881J
Mar 17, 2017
WRITTEN OFF
$0
Jul 11, 2016Construction CLASS - 1
FAILURE TO SAFEGUARD HOLES AND OPENINGS. AT TIME OF INSPECTION I OBSERVED LARGE SHAFT WAY OPENING RUNNING THRU THE APARTMENTS.NO COVERS OR NO GUARDRAILS TO PREVENT FALLING THROUGH FLOOR ONTO NEXT FLOOR.SHAFTWA
#35195882L
Mar 17, 2017
WRITTEN OFF
$0
Oct 16, 2014Construction CLASS - 1
SEC. 3307.3.2 FAILURE TO PROVIDE JOB SITE FENCE AS REQUIRED. AT TIME OF INSPECTION ACTIVE CONSTRUCTION SITE: FENCE ALONG EXPOSURE 2 IS A 6' CHAIN LINK FENCE & NOT A 8'-0" WOODEN CONSTRUCITON FENCE AS REQUIRED
#35110580K
Apr 16, 2015
WRITTEN OFF
$0
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 14, 2026, 4:55 PM ET. BBL 1019440023.