Manhattan · Block 923 · Lot 11 · 10003

313 East 17 Street

12 floors · 70,848 sq ft · built 1965 · class I1 · owner of record: 317 East 17th Street Llc

12open violations
$30,625ECB/OATH penalties owed
0HPD class C (immediately hazardous)
44dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 44 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 44 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 70,848 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 165 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 165 days
Annual filing
Energy audit and retro-commissioning (2033) Likely applies
Local Law 87 · Calendar year 2033
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 923). Agency page

Dec 31, 2033
in 2601 days
Next due 2033
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $1,526,000 in late-filing or failure-to-file penalties. Agency page

On fileCycle 10 filing on record: SAFE (2026-04-17)

Open violations

ECB / OATH (3) · $30,625 owed
IssuedViolationHearingBalance
Sep 3, 2026Elevators CLASS - 2
VF... HOIST MACHINE BRAKE MAINTENANCE TAG UPDATE MISSING PROVIDE... 8.6.4.6... CAT 1 TAG MISSING PROVIDE.. 8.11.2.2... CAT 5 TAG MISSING PROVIDE 8.6.1.4.1(B).... COMMUNICATION DEFECTIVE REPAIR 8.6.4.15.. PIT LI
#39202982R
Dec 24, 2026
PENDING
$625
Sep 5, 2025Construction CLASS - 1
SUMMONS ISSUED FOR FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS DUE TO A PIECE OF SHEET METAL FALLING FROM BUILDING AND DAMAGING A DOCTORS CAR THAT WAS PARKED ON 17TH STREET
#39159430H
Feb 23, 2027
$25,000
Sep 5, 2025Construction CLASS - 1
SUMMONS ISSUED FOR FAILURE TO PROMPTLY NOTIFY THE DEPARTMENT OF AN INCIDENT OR DAMAGE TO ADJOINING PROPERTY AT CONSTRUCTION SITE. APIECE OF SHEET METAL HAD FALLEN FROM BUILDING DAMAGING A DOCTORS CAR THAT WAS P
#39159431J
Feb 23, 2027
$5,000
DOB (3)
IssuedViolationStatus
Jun 17, 2024HAZARDOUS CONDITION (FACADE)
CYCLE 9C UNSAFE REPORT FILED
#911866
DOB VIOLATION - ACTIVE
Feb 22, 2024NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
#01617
DOB VIOLATION - ACTIVE
Feb 20, 2019FACADE SAFETY PROGRAM

#HAZ88022
DOB VIOLATION - ACTIVE
DOB NOW Safety (8)
IssuedViolationStatus
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 2, 2026Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2025 Periodic Inspection Report
Active
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Jan 14, 2026Facades FTC-FC-UNSAFE
Unsafe report filed
Active
Jun 17, 2024Facades FISPHAZ
CYCLE 9C UNSAFE REPORT FILED
Active
Feb 22, 2024Facades FISPNRF
FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024
Active
Feb 20, 2019Facades FISP
CYCLE 8C UNSAFE REPORT FILED
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Periodic Inspection ReportOpen
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen
Sep 3, 2026ECBElevators: VF... HOIST MACHINE BRAKE MAINTENANCE TAG UPDATE MISSING PROVIDE... 8.6.4.6... CAT 1 TAG MISSING PROVIDE.. 8.11.2.2... CAT 5 TAG MISSING PROVIDE 8.6.1.4.1(B).... COMMUNICATION DEFECTIVE REPAIR 8.6.4.15.. PIT LIOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 17, 2026, 6:58 PM ET. BBL 1009230011.