7 floors · 15,651 sq ft · built 1920 · class O6 · owner of record: Cimantob Realty Co.,
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $288,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 850 days | Filing window not open yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1163 days | Next cycle year 2029 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-30 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 1, 2020 | Construction CLASS - 2 REMOVAL OF SIDEWALK SHED W/O DOB APPROVAL.AT TIME OF INSPECTION,BUILDING FACADE WAS STILL DESIGNATED AS SWAMP,THE AMENDED FACADE REPORT(TR6)HAD NOT BEEN ACCEPTED AND SAFETY MEASURES HAD ALREADY BEEN REMOVED.REM #35539027R | Jul 8, 2021 IN VIOLATION | $0 |
| Aug 25, 2020 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG WALLS AND APPURTENANCES.AS NOTED:AT TIME OF INSPECTION OBSERVED ON EXPO#1:OPEN MORTAR JOINTS AT COPING;LOOSE OBJECTS ON ROOF;CRACK ON CHIMNEY.REM:MAINTAIN EXTERIOR BLDG WALLS A #35538963P | Jul 8, 2021 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 10, 2000 | ELEVATOR 9444/126368 #9444/126368 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Apr 30, 2019 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019 | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Oct 25, 2026, 4:43 AM ET. BBL 1008330044.