Manhattan · Block 142 · Lot 25 · 10013

310 Greenwich Street

39 floors · 1328 apartments · 2,079,746 sq ft · built 1975 · class D6 · owner of record: Ip Mortgage Borrower Llc

141open violations
$39,804ECB/OATH penalties owed
4HPD class C (immediately hazardous)
47dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 47 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 63 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 2,079,746 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 168 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 168 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 291 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 778 days
Next cycle year 2028
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $224,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 830 days
Filing window not open yet
Energy audit and retro-commissioning (2032) Likely applies
Local Law 87 · Calendar year 2032
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 142). Agency page

Dec 31, 2032
in 2239 days
Next due 2032
Annual boiler inspection (4 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-08 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (32) · $39,804 owed
IssuedViolationHearingBalance
Dec 12, 2025Unknown CLASS - 1
FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN OCCUPIED PARKING GARAGE CONSISTING OF 02 LEVELS. OBSERVED (*)MULTIPLE AREAS OF CRACKED, SPALLED, DETERIORATED CONCR
#35726708X
Dec 14, 2026
PENDING
$2,500
Dec 12, 2025Unknown CLASS - 1
FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN OCCUPIED PARKING GARAGE CONSISTING OF 02 LEVELS. OBSERVED (*)MULTIPLE AREAS OF CRACKED, SPALLED, DETERIORATED CONCR
#35726707Y
May 13, 2027
PENDING
$2,500
Dec 12, 2025Unknown CLASS - 1
FAILURE TO MAINTAIN PARKING STRUCTURES IN SAFE CONDITION. AS NOTED: ATTIME OF INSPECTION ON AN OCCUPIED PARKING GARAGE CONSISTING OF 02 LEVEL OBSERVED #)MULTIPLE AREAS OF CRACKED AND SPALLED CONCRETE INCLUDING
#35726237Z
Dec 11, 2026
DEFAULT
$2,530
Dec 12, 2025Unknown CLASS - 1
FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED AT TIME OF INSPECTION ON AN OCCUPIED PARKING GARAGE CONSISTING OF 02 LEVELS OBSERVED *)MULTIPLE AREAS OF CRACKED AND SPALLED CONCRETE INCLUDING
#35726234N
Dec 11, 2026
DEFAULT
$12,500
Dec 12, 2025Unknown CLASS - 1
FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION. AS NOTED: AT TIME OF INSPECTION ON AN OCCUPIED PARKING GARAGE CONSISTING OF 02 LEVELS. OBSERVED (*)MULTIPLE AREAS OF CRACKED, SPALLED, DETERIORATED CONCR
#35726709H
Nov 5, 2026
IN VIOLATION
$2,500
Sep 17, 2025Unknown CLASS - 1
A8: ELECTRICAL WORK WITHOUT A PERMIT FOR THE INSTALLATION OF 20 JOCO CHARGING STATION, 5 OUTLETS, & BRANCH CIRCUIT WIRING IN THE GARAGE. AN APPLICATION FOR CERTIFICATE OF ELECTRICAL INSPECTION IS NOT ON FILE.,
#39160745K
Jan 19, 2027
$4,000
Sep 9, 2025Construction CLASS - 2
ATOI, DID NOT GAIN ACCESS INTO PREMISES. HOWEVER, OBSERVED PERMIT #M01224189-I1-PMM, EXPIRING 05/19/2026, IS UPDATED AS PER DOB RECORDS BUT NOT POSTED., POST/PROPERLY POST PERMIT
#39159814R
Sep 8, 2026
IN VIOLATION
$150
Apr 24, 2024Unknown CLASS - 2
AT THE TIME OF INSPECTION, I OBSERVED THAT THERE WAS NO FIRE EXTINGUISHER ON SITE AS REQUIRED BY FIRE CODE.. PROVIDE AND MAINTAIN FIRE EXTINGUISHERS.
#39527946P
Jul 11, 2024
DEFAULT
$1,562
Dec 12, 2023Construction CLASS - 1
UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 35473879H ISSUED ON 08/21/20 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY
#39101193L
Feb 15, 2024
DEFAULT
$6,250
Jun 23, 2023Construction CLASS - 2
OBSERVED AT BOTH LEVEL OF OCCUPY PARKING GARAGE LARGE SECTION OF CONCRETE MISSING AND EXPOSING REBAR., REPAIR AND/OR REPLACE; REPAIR AND/OR REPLACE
#39089037K
Aug 31, 2023
IN VIOLATION
$0
May 5, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTED : OBSERVED AT FIRST FLOOR,AND CELLAR LEVEL THERE ARE CRACKS,AND HOLES AT VARIOUS LOCATION., REPAIR AND/OR REPLACE
#39085590H
Jul 13, 2023
IN VIOLATION
$0
Sep 9, 2020Unknown CLASS - 2
FAILURE TO POST OR DISTRIBUTE TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION OBSERVED WORK BEING PERFORMED UNDER THE AFFORMETIONED JOB NUMBER AT TIME OF INSPECTION TPP WAS NOT POSTED AT JOB SITE.BY CODE TPP
#35473986N
Nov 19, 2020
IN VIOLATION
$1,250
Sep 9, 2020Construction CLASS - 1
BC28-104.8.4/INADEQUATE TENANT PROTECTION PLAN.NOTE:AT TIME OF INSPECTION OBSERVED WORK BEING PERFORMED UNDER THE AFFORMENTIONED JOB NUMBER THE SUBMITTED TPP LACKS SPECIFIC MEANS AND METHODS OF PROTECTING TENAN
#35473987P
Nov 19, 2020
IN VIOLATION
$2,500
Aug 17, 2020Construction CLASS - 2
FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION DOCUMENTS AT JOB SITE AT TIME OF INSPECTION. NOTE:AT TIME OF INSPECTION ASKED FOREMAN FOR PLANS&PERMIT FOREMAN STATED THAT THERE ARE NO PLANS ON SITE. REMEDY:CO
#35473978N
Oct 22, 2020
DEFAULT
$1,562
Aug 17, 2018Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. FAILURE TO PROVIDE NUMBER OF REQUIRED MEANS OF EGRESS FOR EVERY FLOOR OF REQUIRED MEANS OF EGRESS FOR EVERY FLOOR PER BC1021.1; 1018.1 AND 27-366 FOR TRANS
#35348112J
Mar 7, 2019
IN VIOLATION
$0
Aug 17, 2018Construction CLASS - 1
BC907.2.8 FAILURE TO PROVIDE FIRE ALARM SYSTEM FOR TRANSIENT USE. REM: DISCONTINUE ILLEGAL OCCUPANCY.
#35348113L
Mar 7, 2019
IN VIOLATION
$0
Aug 17, 2018Construction CLASS - 1
OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY #78823. NOW 1ST FL ILLEGALLY USED/CONVERTED TO TRANSIENT USE. NOTED: 3 GUESTS STAYING IN APT FOR LESS THAN 30 DAYS. REM: DISCONTINUE ILLEGAL OC
#35348111H
Mar 7, 2019
IN VIOLATION
$0
Apr 11, 2018Construction CLASS - 1
CEASE USE. 97R5,64M7. (97R)ILLEGAL INSTALLATION OF DUMBWAITER PERFORM & FILE TEST, NYC DEVICE MISSING. (98)CURRENT 1 YEAR TEST TAG.
#38262529R
May 31, 2018
IN VIOLATION
$0
Apr 11, 2018Construction CLASS - 1
CEASE USE. 30D6,99M5,64B7,68B7. (30D)NORMAL/FINAL UNITS UNSECURED. (99M)CURRENT 1 YEAR TAG MISSING, PERFORM & FILE TEST. (68B)LOG BOOK NOT UP TO DATE. (64B)NYC DEVICE#NOT ON TAG.
#38262528P
May 31, 2018
IN VIOLATION
$0
Apr 12, 2017Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR FACADE NORTH ELEV EXP#3 BALCONY FRONTS,CEILINGS & FACIA MISSING,GROUT(ERODED). AT UPPER FLOORS BALCONY CEILINGS SPALLING EXPOSED REBAR. ROOF AT NORTH BULKHEAD-MISSING & ERODED GROUT
#35253705N
Mar 15, 2018
IN VIOLATION
$0
Jul 21, 2016Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BLDG ROOF-BULKHEAD ERODED COPING AND MORTAR JOINTS. PARAPET JOINTS AT ROOF SEALANT DRIED ERODED MORTAR-SOUTH ELEV EXP1 3RD FLR SOFFIT CRAZING CONCRETE EXPOSED REBAR.CRAZING/CRACKING
#35174595X
Sep 8, 2016
DEFAULT
$0
Dec 4, 2015Construction CLASS - 2
FAILURE TO MAINTAIN EXTERIOR BLDG NORTH ELEV EXP#1-1ST FL LINTELS RUSTING VERTICLE CRACLS-BALCONIES CRACKS CRAZING EXPOSED REBAR. AT SLABS MISSING MORTAR AT BALCONIES RAILINGS EAST ELEV EXP#2-LOWER FLOOR SET
#35133861Z
Jan 21, 2016
DEFAULT
$0
Oct 22, 2014Construction CLASS - 2
WORK DOES NOT CONFORM TO APPROVED CONST DOCUMENTS NOTED:JOB#110054324 TO SIDEWALK REPAIR NOT INCLUDING @ SIDE NORTH MOORE ST CURB CUT APPROX 30'LLONG W/ 2 SPLAYS.CURB CUT NO SERVE TO DRIVEWAY OR GARAGE.REM:OBTA
#35153230K
Jan 8, 2015
IN VIOLATION
$0
Mar 7, 2014Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER: NO FIRE STOPPING PER BC 712.3;27-345. NOTE: CEILING PENETRATIONS (NEW) THROUGHOUT MAIN LEVEL CEILING OF GARAGE ARE W/O ADEQUATE FIRE STOPPING. (PLYWOOD,PLASTIC
#35033274X
Apr 24, 2014
ADMIT/IN-VIO
$0
Oct 21, 2009Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. DEFECTS NOTED: INADEQUATE FIRE STOPPING @ CMU WALLS VARIOUS LOCATIONS @ GARAGE WITH MISSING CAR STOPS & PROTECTIONS FOR MECHANICAL EQUIPMENT (ETAL). CRACKE
#34818256X
May 20, 2010
DEFAULT
$0
Oct 21, 2009Construction CLASS - 1
FAILURE TO PROVIDE UNOBSTRUCTED EXIT PASSAGEWAY EXIT DOORS @ VARIOUS LOCATIONS,WITH EXIT SIGNS SHOWING LOCATIONS OF EXITS,FOUND WITH KEY OPERATED LOCKS INSTALLED & DOORS SWUNG INGRESS DUE TO REARRANGEMENT SWING
#34818252Z
May 20, 2010
DEFAULT
$0
Oct 21, 2009Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BLDG WALLS & OR APPURTENANCES. DEFECTS NOTED: AT BUILDING FACADE ON THE EAST ELEVATION AT,NORTHEAST,ENTRY TO LOWER LEVEL,FOR GARAGE,FOUND WITH BROKEN,DEFECTIVE,DISLODGED CRACKED &
#34818255Y
May 20, 2010
DEFAULT
$0
Oct 15, 2009Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BLDG WALL(S) AND OR APPURTENANCES.DEFECTSNOTED:BROKEN DEFECTIVE CRACKED LOOSE BRICKS BELOW STRUCTURAL STEEL DOUBLE ANGLES LINTEL,AT ENTRY TO LOWER LEVEL FOR GARAGE IN DANGER OF FALL
#34810529X
May 20, 2010
DEFAULT
$0
Oct 15, 2009Construction CLASS - 1
FAILURE TO MAINTAIN INTERIOR BLDG IN CODE COMPLIANT MANNER. DEFECTS NOTED:NUMEROUS CRACKS @ CEILING & WAFFLE SLAB W/EXPOSED REBARS @ BEAMS W/LOOSE MORTAR & CINDER BLOCK WALLS W/CRACKS AT VARIOUS LOCATIONS SECTI
#34810533Z
May 20, 2010
DEFAULT
$0
Oct 15, 2009Construction CLASS - 1
FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.IMPROPER EXIT,EXIT ACCESS DOORWAY ARRANGEMENT PER BC 1014.2: AT NICHES TO GARAGE EXIT DOORS,AT VARIOUS LOCATIONS,FOUND INSTALLED NEW STEEL DOORS W/BUCKS WHICH
#34810532R
May 20, 2010
DEFAULT
$0
Sep 30, 2009Unknown CLASS - 2
SEC27292.5PEOPLE WITH PHYSICAL DISABILITIES FAILURE TO PRVDE ADEQUATE ACCESS NOTED:AT ENTRY DR TO M/D WING OF PREMISES A MAKE SHIFT WOOD RAMP TERMINATES DRCTLY AT DR W/O A LANDING ACTUAL DOOR OPNG MEASURES 33"
#34809404Y
Jan 20, 2011
DEFAULT
$0
Mar 24, 2006Site Safety Non-Hazardous
FAILURE TO PROVIDE CONTRACTOR'S SIGN ON SHED. REMEDY: PROVIDE CONTRACTORS SIGN ON SHED.
#34517092J
Aug 3, 2006
WRITTEN OFF
$0
DOB (24)
IssuedViolationStatus
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#23940
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#06355
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#06354
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#06353
DOB VIOLATION - ACTIVE
Dec 9, 2020FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00175
DOB VIOLATION - ACTIVE
Dec 30, 2015FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00114
DOB VIOLATION - ACTIVE
Oct 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
#02756
DOB VIOLATION - ACTIVE
Oct 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
#02757
DOB VIOLATION - ACTIVE
Oct 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
#02758
DOB VIOLATION - ACTIVE
Oct 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
#02759
DOB VIOLATION - ACTIVE
Oct 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
#02760
DOB VIOLATION - ACTIVE
Oct 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2013 INSPECTION/TEST
#02761
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
#05001
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
#05004
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
#05003
DOB VIOLATION - ACTIVE
Mar 31, 2014ELEVATOR ANNUAL INSPECTION / TEST
VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
#05002
DOB VIOLATION - ACTIVE
Aug 15, 2012ELEVATOR

#ACC200060
DOB VIOLATION - ACTIVE
Aug 15, 2012ELEVATOR

#ACC200062
DOB VIOLATION - ACTIVE
Dec 21, 2011CONSTRUCTION

#CN10101MD
DOB VIOLATION - ACTIVE
Apr 2, 2007LOCAL LAW 10/81 - ELEVATOR

#00101
DOB VIOLATION - ACTIVE
Apr 2, 2007LOCAL LAW 10/81 - ELEVATOR

#00102
DOB VIOLATION - ACTIVE
Jul 20, 2005ELEVATOR

#9444/136263
DOB VIOLATION - ACTIVE
Jul 20, 2005ELEVATOR

#9444/136261
VIOLATION WORK WITHOUT PERMIT - ACTIVE
Mar 5, 2003ELEVATOR
1P35616
#9013/168078
DOB VIOLATION - ACTIVE
DOB NOW Safety (44)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 1)
Active
Dec 4, 2024Parking Structures FTF-PS-INITL
Failure to file sub cycle 1A parking structures compliance report by 12/31/2023, as required per 1 RCNY 103-13.
Active
Oct 11, 2024Elevators FTC-VT-CAT1-CO
Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction
Active
Sep 11, 2024Elevators FTF-VT-CAT1-NJ
Violation Issued-Failure To File 2023 Cat1 Test Report
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
Aug 11, 2023Elevators FTF-VT-CAT1-NJ
Violation Issued-Failure To File 2020 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-NJ
Violation Issued-Failure To File 2022 Cat1 Test Report
Active
Aug 11, 2023Elevators FTF-VT-CAT1-NJ
Violation Issued-Failure To File 2021 Cat1 Test Report
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Dec 9, 2020AEUHAZ FTC-AEU-HAZ
Active
Dec 30, 2015AEUHAZ FTC-AEU-HAZ
Active
Oct 31, 2014Elevators EVCAT1
Active
Oct 31, 2014Elevators EVCAT1
Active
Oct 31, 2014Elevators EVCAT1
Active
Oct 31, 2014Elevators EVCAT1
Active
Oct 31, 2014Elevators EVCAT1
Active
Oct 31, 2014Elevators EVCAT1
Active
Mar 31, 2014Elevators EVCAT1
Active
Mar 31, 2014Elevators EVCAT1
Active
Mar 31, 2014Elevators EVCAT1
Active
Mar 31, 2014Elevators EVCAT1
Active
Aug 15, 2012Elevators E
Active
Aug 15, 2012Elevators E
Active
Aug 15, 2012Elevators E
Active
Aug 15, 2012Elevators E
Active
Aug 15, 2012Elevators E
Active
Aug 15, 2012Elevators E
Active
Apr 2, 2007Elevators LL1081
Active
Apr 2, 2007Elevators LL1081
Active
Apr 2, 2007Elevators LL1081
Active
Apr 2, 2007Elevators LL1081
Active
Apr 2, 2007Elevators LL1081
Active
Apr 2, 2007Elevators LL1081
Active
HPD (48) · C 4 · B 35 · A 9
IssuedClassViolationCorrect by
Aug 24, 2026BApt 38J · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WASHBASIN CABINET IN THE BATHROOM LOCATED AT APT 38J, 38th STORY, 1st APARTMENT FROM WEST AT NORTHSep 28, 2026
Aug 24, 2026BApt 9B · § 27-2005 ADM CODE PROPERLY SECURE THE LOOSE DISHWASHER IN THE KITCHEN LOCATED AT APT 9B, 9th STORY, 2nd APARTMENT FROM SOUTH AT WESTSep 28, 2026
Aug 21, 2026BApt 38J · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SHOWER FAUCET AT BATHTUB IN THE BATHROOM LOCATED AT APT 38J, 38th STORY, 1st APARTMENT FROM WEST AT NORTHSep 25, 2026
Aug 21, 2026BApt 9B · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 9B, 9th STORY, 2nd APARTMENT FROM SOUTH AT WESTSep 25, 2026
Aug 21, 2026BApt 38J · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING IN THE 2nd ROOM FROM EAST LOCATED AT APT 38J, 38th STORY, 1st APARTMENT FROM WEST AT NORTHSep 25, 2026
Aug 21, 2026BApt 38J · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE KITCHEN LOCATED AT APT 38J, 38th STORY, 1st APARTMENT FROM WEST AT NORTHSep 25, 2026
Aug 21, 2026BApt 38A · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM AT WEST WALL IN THE BATHROOM LOCATED AT APT 38A, 38th STORY, 2nd APARTMENT FROM SOUTH AT WESTSep 25, 2026
Aug 21, 2026BApt 9B · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 9B, 9th STORY, 2nd APARTMENT FROM SOUTH AT WESTSep 25, 2026
Aug 10, 2026AApt 23K · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 23K, 23rd STORY, 3rd APARTMENT FROM SOUTH AT WESTNov 13, 2026
Aug 6, 2026BApt 39A · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT. AT CEILING IN THE BATHROOM LOCATED AT APT 39A, 39th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18777173 ISSUED 03-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-20Sep 10, 2026
Jul 20, 2026BApt 3H · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE AT LOWER CABNET DOOR IN THE KITCHEN LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTAug 24, 2026
Jul 9, 2026AApt 17D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 17D, 17th STORY, 2nd APARTMENT FROM EAST AT SOUTHOct 12, 2026
Jun 22, 2026BApt 3D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''EAST'' ORIGINAL VIOLATION 18653893 ISSUED 18-FEB-26 HAS BEEN UPGRADED TO CLASS B PER ADMJul 27, 2026
Jun 3, 2026B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AT COMPACTOR CLOSET DOOR [ 1ST FROM EAST ] AT 11TH STORYJul 8, 2026
Jun 3, 2026A§ 27-848 ADMIN CODE & DEPT. RULES AND REGS. REPLACE REFUSE CHUTE WARNING SIGN PUBLIC HALL DOOR TO SERVICE CLOSET OR ON WALL OVER HOPPER DOOR AT HOPPER CHUTE DOORS AT ENTIRE BUILDINGSep 6, 2026
Apr 23, 2026BApt 20K · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 20K, 20th STORY, 2nd APARTMENT FROM NORTH AT EASTMay 28, 2026
Apr 23, 2026AApt 14C · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 14C, 14th STORY, 1st APARTMENT FROM WEST AT NORTHJul 27, 2026
Apr 2, 2026BApt 18E · § 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE .. IN THE ENTIRE APARTMENT LOCATED AT APT 18E, 18th STORY, 2nd APARTMENT FROM WEST AT NORTHMay 7, 2026
Apr 2, 2026BApt 18E · 566 (B) 27-2021.4 HMC: ABATE THE NUISANCE CONSISTING OF PESTS. EVIDENCE OF FLIES IN THE ENTIRE APARTMENT LOCATED AT APT 18E, 18th STORY, 2nd APARTMENT FROM WEST AT NORTHMay 7, 2026
Apr 2, 2026BApt 36D · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 36D, 36th STORY, 3rd APARTMENT FROM WEST AT NORTHMay 7, 2026
Mar 17, 2026BApt 9A · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL HOUSE HOLD MATERIALS, STACKED BOXES IN THE ENTIRE APARTMENT LOCATED AT APT 9A, 9th STORY, 2nd APARTMENT FROM EAST AT SOUTHApr 21, 2026
Mar 2, 2026AApt 18E · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 1st ROOM FROM EAST LOCATED AT APT 18E, 18th STORY, 3rd APARTMENT FROM EAST AT SOUTHJun 5, 2026
Feb 19, 2026AApt 3D · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''EAST''May 25, 2026
Nov 21, 2025BApt 3D · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT THE BATHTUB IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHDec 26, 2025
Nov 21, 2025AApt 3D · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT THE CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTHFeb 24, 2026
Oct 22, 2025CApt 31G · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 5, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 31G, 31st STORY, 3rd APNov 17, 2025
Oct 22, 2025BApt 31G · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF COOKING GAS OPERATED STOVE INSTALLED NEXT TO PAINTED WALL, EXPOSED TO GAS BURNERS IN THE KITCHEN LOCATED AT APT 31G, 31st STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''East''Nov 26, 2025
Oct 22, 2025BApt 31G · § 27-2005 HMC: REFIT DOOR TO TERRACE AT EAST WALL IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 31G, 31st STORY, 3rd APARTMENT FROM NORTH AT EAST , SECTION ''East''Nov 26, 2025
Aug 11, 2025BApt 3D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ. FT. AT WASH BASIN CABINET IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17818011 ISSUED 04-APR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE Sep 15, 2025
Aug 11, 2025BApt 3D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQUARE FEET AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17818020 ISSUED 04-APR-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §2Sep 15, 2025
Apr 11, 2025BApt 9F · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE 2nd ROOM FROM NORTH LOCATED AT APT 9F, 9th STORY, 4th APARTMENT FROM EAST AT SOUTHMay 16, 2025
Apr 11, 2025AApt 3D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CAULKING AROUND BATHTUB IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTHJul 15, 2025
Apr 11, 2025BApt 3D · § 27-2026 ADM CODE REPAIR THE LEAKY AND/OR DEFECTIVE FAUCETS AT BATHTUB IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTHMay 16, 2025
Oct 18, 2024BApt 3D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 4 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 17063416 ISSUED 14-JUN-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(Nov 22, 2024
Oct 10, 2024BApt 32J · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 32J, 32nd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 14, 2024
Jun 4, 2024BApt 2C · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING APPROX. 20 SQ. FT. IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM NORTH AT EASTJul 9, 2024
May 28, 2024BApt 10K · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL THROUGH OUT IN THE ENTIRE APARTMENT LOCATED AT APT 10K, 10th STORY, 1st APARTMENT FROM NORTH AT EASTJul 2, 2024
Aug 2, 2023BApt 3D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROXIMATELY 1 SQ FT AT WASH BASIN CABINET IN THE BATHROOM LOCATED AT APT 3D, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 15876737 ISSUED 31-MAR-23 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVESep 6, 2023
Sep 22, 2022BApt 3D · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 10 SQ FT AT WEST WALL OF CLOSET IN THE 1st ROOM FROM EAST LOCATED AT APT 3D, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH , SECTION ''EAST ''Oct 27, 2022
Mar 18, 2022BApt 5L · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... 8 SQ FT AT THE CEILING IN THE BATHROOM LOCATED AT APT 5L, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 14680288 ISSUED 17-NOV-21 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(Apr 22, 2022
Mar 14, 2022BApt 10K · § 27-2005, 2012 HMC & § 309 MDL: ABATE THE NUISANCE CONSISTING OF EXCESSIVE STORAGE OF MATERIAL MAKING IT DIFFICULT TO NAVIGATE THROUGH UNIT IN THE ENTIRE APARTMENT LOCATED AT APT 10K, 10th STORYApr 18, 2022
Jan 26, 2022BApt 30J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... .... 20 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 30J, 30th STORY, 3rd APARTMENT FROM SOUTH AT WESTMar 2, 2022
Apr 2, 2021BApt 30J · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... .. AT CEILING 15 SQ FT IN THE BATHROOM LOCATED AT APT 30J, 30th STORY, 3rd APARTMENT FROM SOUTH AT WESTMay 7, 2021
Jul 21, 2020AApt 39K · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT CEILING AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 39K, 39th STORY, 1st APARTMENT FROM WEST AT NORTHOct 24, 2020
Jul 18, 2017CApt 9J · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM EAST AT SOUTH WALL IN THE 2nd ROOM FROM EAST AT SOUTH LOCATED AT APT 9J, 9th STORY, 1st APARTMAug 29, 2017
Mar 22, 2007CApt B · SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK & ASSEBLY AT DOOR IN THE ENTRANCE LOCATED AT APT B, 1st STORY, 1st APARTMENT FROM NORTH AT EASTApr 2, 2007
Mar 22, 2007BSECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK & ASSEBLY AT ENTRANCE TO BUILDING DOOR AT PUBLIC HALL, 1st STORYMay 1, 2007
Apr 11, 2005CApt 32J · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st WINDOW FRAME FROM NORTH AT EAST WALL IN THE 2nd ROOM FROM NORTH LOCATED AT APT 32JMay 7, 2005

Issued in the last 120 days

DateSourceWhatNow
Aug 24, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WASHBASIN CABINET IN THE BATHROOM LOCATED AT APT 38J, 38th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Aug 24, 2026HPD B§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE DISHWASHER IN THE KITCHEN LOCATED AT APT 9B, 9th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Aug 21, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE SHOWER FAUCET AT BATHTUB IN THE BATHROOM LOCATED AT APT 38J, 38th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Aug 21, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 9B, 9th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Aug 21, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOORING IN THE 2nd ROOM FROM EAST LOCATED AT APT 38J, 38th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Aug 21, 2026HPD B§ 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES AT CEILING IN THE KITCHEN LOCATED AT APT 38J, 38th STORY, 1st APARTMENT FROM WEST AT NORTHOpen
Aug 21, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION SYSTEM AT WEST WALL IN THE BATHROOM LOCATED AT APT 38A, 38th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Aug 21, 2026HPD B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOOD FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 9B, 9th STORY, 2nd APARTMENT FROM SOUTH AT WESTOpen
Aug 10, 2026HPD A§ 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING AND ALL WALLS IN THE BATHROOM LOCATED AT APT 23K, 23rd STORY, 3rd APARTMENT FROM SOUTH AT WESTOpen
Aug 6, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10 SQ FT. AT CEILING IN THE BATHROOM LOCATED AT APT 39A, 39th STORY, 1st APARTMENT FROM WEST AT NORTH ORIGINAL VIOLATION 18777173 ISSUED 03-APR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-20Open
Jul 30, 2026HPD B§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THEN 8 SQ FT AT CEILING IN THE BATHROOM LOCATED AT APT 7L, 7th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 18755391 ISSUED 30-MAR-26 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE 27-2017.3Closed
Jul 20, 2026HPD C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES TO STAIR CASE DOOR A AT PUBLIC HALL, 1st STORYClosed
Jul 20, 2026HPD B§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS THAT IS DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM NORTH AT Closed
Jul 20, 2026HPD B§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE AT LOWER CABNET DOOR IN THE KITCHEN LOCATED AT APT 3H, 3rd STORY, 1st APARTMENT FROM NORTH AT EASTOpen