Manhattan · Block 1336 · Lot 40 · 10017

310 East 44 Street

16 floors · 324 apartments · 206,598 sq ft · built 1930 · class D6 · owner of record: Beaux Arts Realty

28open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
43dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 43 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 43 days
Keep the report on file (not filed with DOB)
Energy audit and retro-commissioning (2026) Likely applies
Local Law 87 · Calendar year 2026
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1336). Agency page

Dec 31, 2026
in 43 days
Due this year
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 43 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 59 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. DOB facade records for this building show $726,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2027
in 95 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 206,598 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 164 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 164 days
Annual filing
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 287 days
Registered through 2027-09-01
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-19 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (7)
IssuedViolationHearingBalance
Feb 14, 2024Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING WALL AND APPURTENANCES. AT TIME OF INSPECTION, I OBSERVED DEFECTED MORTAR JOINTS, CRACKED BRICKS. DAMAGED MASONRY AT EXPO(1) NORTH ELEV.(PARAPET AREAS) VARIOUS LOCATIONS. REMEDY: MA
#35682485X
Oct 22, 2024
IN VIOLATION
$0
Jan 16, 2024Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#804654.AGG1:PRIOR NOV 37022259R UNDER 28-302.5
#37026076M
Mar 27, 2025
IN VIOLATION
$0
Jun 6, 2023Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES.OBSERVED LARGE STEP-CRACKED BRICKWORK AT EXPOSURE#2 EAST ELEVATION.CONDITION WAS NOT LISTED IN QEWI REPORT.REM:MAINTAIN EXTERIOR FACADE.TAKE SAFETY
#35674111L
Sep 21, 2023
IN VIOLATION
$0
Apr 14, 2023Construction CLASS - 1
AT TIME OF INSPECTION OBSERVED FRONT FACADE MASONRY BRICK WALL INSTATE OF DISREPAIR CONDITIONS WITH CRACKS, DEFLECTION, LOOSE AND UNPLUMBED 10 TO 12TH FLOOR OF EASTERN WINDOW BAY ON EXPOSURE 01 (NORTH FACADE).
#39083802L
Jun 22, 2023
DEFAULT
$0
Dec 9, 2022Local Law CLASS - 2
FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 9A REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#904654.REM:SUBMIT ACCEPTABLE REQUIRED T
#37025046R
Mar 23, 2023
DEFAULT
$0
Oct 8, 2021Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 8A REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL#804654. REMEDY: FILE ACCEPTABLE REPORT.
#37022259R
Mar 3, 2022
DEFAULT
$0
Feb 21, 2017Plumbing CLASS - 2
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER RE:INSTALLATION MAINTENANCE OF PLUMBING MATERIALS/EQUIPMENT PER PC 102.3; 27-902 NOTED GROUND/1ST FLR COMMERCIAL LAUNDRY AREA EQUIPPED/INSTALLED FLEX
#35220612N
Apr 13, 2017
DEFAULT
$0
DOB (12)
IssuedViolationStatus
Jun 30, 2026CONSTRUCTION
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER: DOB VIOLATION #041825CFA0 302AE REQUIRED THE IMMEDIATE 100% HANDS ON INSPECTION OF ALL FACADES BY A PE/RA & SUBMIT A REPORT TO FACADE VIA EMAIL BY 5/2/2025. AS OF 06/30/2026, NO HAND ON INSPECTION REPORT SUBMITTED TO FACADE UNIT REMEDY: COMPLY WITH DOB VI
#LL10307CM
DOB VIOLATION - ACTIVE
Mar 11, 2024PLUMBING
BASED ON COMMISSIONERS SUSPENSION NOTIFICATION ON 2/28/2024 INTENDS TO REVOKE ALL PLUMBING APPROVALS AND PERMIT ISSUED UNDER JOB # M00902370 DUE TO SUSPENSION OF LICENSE MASTER PLUMBER # 002245 STOP ALL PLUMBING WORK UNDER ABOVE MENTIONED PERMIT IMMEDIATELY
#24-00724
DOB VIOLATION - ACTIVE
Feb 19, 2024HAZARDOUS CONDITION (FACADE)
CYCLE 9A UNSAFE REPORT FILED
#911501
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00458
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00457
DOB VIOLATION - ACTIVE
Jun 30, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
#07899
DOB VIOLATION - ACTIVE
Apr 14, 2023CONSTRUCTION
AT TIME OF INSPECTION OBSERVED FRONT FACADE MASONRY BRICK WALL INSTATE OF DISREPAIR CONDITIONS WITH CRACKS, DEFLECTION, LOOSE AND UNPLUMBED 10 TO 12TH FLOOR OF EASTERN WINDOW BAY ON EXPOSURE 01 (NORTH FACADE). ALSO OBSERVED DEFECTED BRICK WALL TEMPORARY SECURED WITH METAL STRAPS.
#23-01012
DOB VIOLATION - ACTIVE
Feb 22, 2022NO REPORT AND / OR LATE FILING (FACADE)
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
#00438
DOB VIOLATION - ACTIVE
Dec 1, 2021FAILURE TO POST ENERGY GRADE/SCORE
FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
#2100756
DOB VIOLATION - ACTIVE
Feb 17, 2017FACADE SAFETY PROGRAM

#HAZ86595
DOB VIOLATION - ACTIVE
Apr 11, 2003ELEVATOR
1F4218
#9013/172886
DOB VIOLATION - ACTIVE
Mar 27, 1989CONSTRUCTION

#B2CR02
VIOLATION UNSERVED ECB-ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Feb 19, 2024Facades FISPHAZ
CYCLE 9A UNSAFE REPORT FILED
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Jun 30, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
Active
Feb 22, 2022Facades FISPNRF
FAILED TO FILE FISP CYCLE 9A TECHNICAL REPORT BY 02/21/2022
Active
Dec 1, 2021Energy Grade - LL33 FTP-EN-EGRDEA
Active
Feb 17, 2017Facades FISP
CYCLE 8A UNSAFE REPORT FILED
Active
HPD (2) · C 0 · B 2 · A 0
IssuedClassViolationCorrect by
Jan 12, 2022BApt 205 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND WALLS IN THE FOYER LOCATED AT APT 205, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTHFeb 16, 2022
Jan 12, 2022BApt 205 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 205, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTHFeb 16, 2022

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 18, 2026, 6:41 AM ET. BBL 1013360040.

Look up another building