Manhattan · Block 385 · Lot 34 · 10009

31 Avenue C

6 floors · 20 apartments · 14,889 sq ft · built 1900 · class C7 · owner of record: 254 East 3rd Street

39open violations
$2,500ECB/OATH penalties owed
7HPD class C (immediately hazardous)
65dto Bedbug annual filing

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 65 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 65 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 81 days
Annual
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 309 days
Registered through 2027-09-01
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 3 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 796 days
Next cycle year 2028
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-16 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (5) · $2,500 owed
IssuedViolationHearingBalance
Aug 19, 2026Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR FACADE. AT TIME OF INSPECTION, OBSERVED AT EXPOSURE 1, ABOVE THE 1ST STORY, A SECTION OF DECORATIVE MASONRY TRIM BECAME DISLODGED AND FELL FROM THE BUILDING. ADDITIONALLY, SECTIONS
#39201010H
Oct 29, 2026
PENDING
$2,500
Apr 22, 2019Boilers CLASS - 2
FOUND 1-WEIL MCLAIN LGB-10 1,170,000 BTU STEAM BOILER. DUE TO UTILITY LOCKING GAS TO BOILER, TENANTS NOT PROVIDED WITH ADEQUATE HEAT. CORRECT VIOLATING CONDITIONS AND SUBMIT CERTIFICATE OF CORRECTION
#39002248X
Jun 6, 2019
IN VIOLATION
$0
Nov 20, 2018Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION#35250113X ISSUED ON 02/02/18 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1 RCNY 102-01(D)(2).AN ACCEPTABLE CERTIFI
#37012429L
Apr 18, 2019
IN VIOLATION
$0
Feb 2, 2018Construction CLASS - 2
WORK WITHOUT PERMIT.NOTED;INSTORE ON CORNER OF BUILDING OBSERVED NEW KITCHEN HOOD WITH DUCT & EXHAUST FAN WERE INSTALLED WITHOUT PERMIT.HOODSIZE APPROX.6'LX 5'W X 2'H AND EXHAUST FAN INSTALLED ON EXTERIOR WALL
#35250113X
Mar 22, 2018
STIPULATION/IN-VIO
$0
Apr 20, 2011Boilers CLASS - 2
B254,15,16,32A,50A,B,C,D,E,F. 50A- DOOR MISSING TO BOILER ROOM. 50B- NO SPILL SWITCH FOR BOILER. 50C- CHECK VALVE MISSING FOR BACKFLOW PREVENTOR. 50D- SEAL HOLES IN WALLS AND CEILING. 50E- EXPOSED WIRES. 50F-
#32070593R
Jun 9, 2011
STIPULATION/IN-VIO
$0
DOB (3)
IssuedViolationStatus
Aug 19, 2026CONSTRUCTION
REQUESTING A STRUCTURAL STABILITY REPORT DUE TO DEFECTS AT EXPOSURE 1, ABOVE THE 1ST STORY, A SECTION OF DECORATIVE MASONRY TRIM BECAME DISLODGED AND FELL FROM THE BUILDING. ADDITIONALLY, SECTIONS OF STONE MASONRY AND BRICKS ARE DETERIORATED AND IN DISREPAIR.
#26-02031
DOB VIOLATION - ACTIVE
Feb 20, 2009CONSTRUCTION

#.0304GR
DOB VIOLATION - ACTIVE
Jan 19, 2007LOCAL LAW 62/91 - BOILERS

#02815
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Jan 8, 2026Gas Piping - LL152 FTF-PL-PER
Cycle 2, Sub-cycle A (premises is in Community District 3)
Active
Jan 19, 2007Boiler LL6291
Active
HPD (29) · C 7 · B 10 · A 12
IssuedClassViolationCorrect by
Jul 31, 2023A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING.Nov 3, 2023
Jan 12, 2023A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WASHING MACHINE ELECTRIC DRYER AT PUBLIC HALL, 3rd STORYApr 17, 2023
Jan 12, 2023B§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WASHING MACHINE WITH DOOR INTACT AT PUBLIC HALL, 3rd STORYFeb 16, 2023
Dec 5, 2022A§ 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WASHING MACHINE AND ELECTRIC DRYER AT PUBLIC HALL, 3rd STORYMar 10, 2023
Dec 5, 2022C§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WASHING MACHINE , DRYER AND ELECTRICAL RANGE AT PUBLIC HALL, 3rd STORYDec 11, 2022
Oct 31, 2022CApt 12 · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 12, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTHOct 30, 2022
Feb 11, 2022BApt 16 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE ...RUBBER GASKET AT REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 16, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHMar 18, 2022
Feb 11, 2022BApt 16 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SLOPING WOOD FLOOR IN THE KITCHEN LOCATED AT APT 16, 5th STORY, 2nd APARTMENT FROM EAST AT SOUTHMar 18, 2022
Jun 7, 2021A§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH AT WINDOW AT PUBLIC HALL STAIRS, 2nd STORYSep 10, 2021
Jun 7, 2021A§ 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE SPRING BALANCE AT LOWER SASH AT WINDOW AT PUBLIC HALL STAIRS, 1st STORYSep 10, 2021
Feb 27, 2020AApt 20 · § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION STAIRS ERECTED LEADING TO ROOF IN THE 2nd ROOM FROM EAST LOCATED AT APT 20, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHJun 1, 2020
Feb 27, 2020CApt 20 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF ROOF JOIST PIERCED CREATING OPENING FROM APT TO ROOF BY MEANS OF METAL STAIRS ERECTED LEADING TO PLEXIGLASS BULKHEAD IN THE 2nd ROOM FROM EAST LOCATED AT APT 20, 6th STORY, 2nd APARTMENT FROM EAST AT SOUTHMar 6, 2020
Jul 18, 2019A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORYOct 21, 2019
May 3, 2019A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORYAug 6, 2019
May 3, 2019A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR , AT PUBLIC HALL, 1st STORYAug 6, 2019
May 3, 2019C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM AT MAILBOX AT PUBLIC HALL, 1st STORYMay 11, 2019
Jul 31, 2017C§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM ON THE BOILER ROOM DOOR AND AT PUBLIC HALL, 1st STORYAug 8, 2017
Jul 31, 2017A§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORYNov 3, 2017
Jul 24, 2017B§ 27-2005 ADM CODE PROVIDE WIRE MESH BELOW AND ABOVE SKYLIGHT AT BULKHEAD ROOFAug 28, 2017
Jul 24, 2017A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYOct 27, 2017
Apr 27, 2017BApt 1 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE KITCHENETTE LOCATED AT APT 1, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHJun 1, 2017
Apr 27, 2017B§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE FIRE RETARDANT CEILING,BULKHEAD AT PUBLIC HALL, 6th STORYJun 1, 2017
Apr 18, 2014CApt 15 · § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK INSTALLED AT THE DOOR LEADING TO THE FIRE ESCAPE WINDOW IN THE 4th ROOM FROM EAST LOCATED AT APT 15, 5th STORY, 1st APARTMENT FROM WEST AT NORTHApr 26, 2014
Jan 28, 2014CApt 11 · § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING KEY OPERATED LOCK INSTALLED AT THE DOOR LEADS TO THE FIRE ESCAPE WINDOW IN THE 4th ROOM FROM EAST LOCATED AT APT 11, 4th STORY, 1st APARTMENT FROM WEST AT NORTHFeb 5, 2014
May 22, 2008BApt 8 · D26-10.01 ADM CODE REPLACE WITH NEW THE MISSING BASEBOARD MOLDING 3 STY REAR SOUTH APT 8 KITCHEN. , SECTION '' ''Jun 26, 2008
May 22, 2008BApt 8 · D26-13.03 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE AND ROACHES 3 STY REAR SOUTH APT 8 THROUGHOUT. , SECTION '' ''Jun 26, 2008
May 22, 2008BApt 8 · D26-10.01 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WOOD FLOOR AND BASEBOARD THROUGHOUT 3 STY SOUTHWEST APT 8. , SECTION '' ''Jun 26, 2008
May 22, 2008AApt 16 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT WALLS AND CEILINGS 5 STY SOUTH APT 16 THROUGHOUT. , SECTION '' ''Aug 25, 2008
May 22, 2008BApt 16 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING MASONRY SADDLE ENTRANCE DOOR 5 STY SOUTH APT 16. , SECTION '' ''Jun 26, 2008

Issued in the last 120 days

DateSourceWhatNow
Aug 19, 2026DOBCONSTRUCTION: REQUESTING A STRUCTURAL STABILITY REPORT DUE TO DEFECTS AT EXPOSURE 1, ABOVE THE 1ST STORY, A SECTION OF DECORATIVE MASONRY TRIM BECAME DISLODGED AND FELL FROM THE BUILDING. ADDITIONALLY, SECTIONS OF STONE MASONRY AND BRICKS ARE DETERIORATED AND IN DISREPAIR.Open
Aug 19, 2026DOBIMMEDIATE EMERGENCY: REMEDY: INSTALL APPROXIMATELY 40 LINEAR FEET OF SIDEWALK SHED ALONG EXPOSURE 1 (EAST 3RD STREET) TO.SAFEGUARD THE PUBLICClosed
Aug 19, 2026ECBConstruction: FAILURE TO MAINTAIN EXTERIOR FACADE. AT TIME OF INSPECTION, OBSERVED AT EXPOSURE 1, ABOVE THE 1ST STORY, A SECTION OF DECORATIVE MASONRY TRIM BECAME DISLODGED AND FELL FROM THE BUILDING. ADDITIONALLY, SECTIONSOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 27, 2026, 10:35 AM ET. BBL 1003850034.

Look up another building