2 floors · 5 apartments · 3,810 sq ft · built 1940 · class C2 · owner of record: Konstantinos Galitos, Trustee
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 61 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 61 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 77 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | No current registration found |
| Gas piping inspection (2028 cycle) Likely applies Local Law 152 · During 2028 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2028 in 792 days | Next cycle year 2028 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 9, 2026 | Construction CLASS - 2 OBSERVED FENCE PERMIT Q00900489-I1-FN EXPIRED ON 08/15/24. LACK OF SUPERVISION IS POTENTIAL HAZARD FOR THE SITE AND THE PUBLIC. #39552827R | Jun 16, 2026 DEFAULT | $6,250 |
| Jun 17, 2024 | Unknown CLASS - 2 OBSERVED UNFINISHED WORK ON THE EXP#3 BALCONIES, LOCATED OVER AND WITHIN 5FT OF THE EXP#4 ADJ PROPERTY- PERMANENT RAILING NOT INSTALLED, BOTTOM OF BALCONY SLABS NOT FINISHED- WHILE NO ADEQUATE PROTECTION HAD BE #39529700Y | Aug 14, 2025 IN VIOLATION | $0 |
| Jun 17, 2024 | Construction CLASS - 2 OBSERVED TWO 6-8FT WIDE SECTION OF CONSTRUCTION/JOBSITE FENCE MISSING IN THE EXP#3 REAR YARD, 1 SECTION ALONG THE EXP#2 PROPERTY LINE, AND THE OTHER ALONG THE EXP#4 PROPERTY LINE- WITH THE BUILDING UNDER ALTERA #39529701X | Aug 14, 2025 IN VIOLATION | $0 |
| Jun 17, 2024 | Unknown CLASS - 2 BC 3301.13 FAILURE TO HAVE CONSTRUCTION SUPERINTENDENT/COMPETENT PERSON ON SITE AS REQUIRED. OBSVD 4 STR ALT1 JOB W/ CS STILL ASSIGNED TO THE JOB/APP- W/ 2 WORKERS ON SITE PERFORMING HVAC WORK. UPON ASKING WORK #39529699X | Aug 14, 2025 IN VIOLATION | $0 |
| Jun 17, 2024 | Construction CLASS - 2 OBSERVE VARIOUS DEBRIS/MATERIAL SCATTERED THROUGHOUT MULTIPLE FLOORS, AS WELL AS EXTENSION CORDS RUNNING THROUGH STAIRCASES AND ON TOP OF THE STEPS. THESE CONDITIONS CREATE TRIPPING HAZARDS FOR ALL PERSONNEL ON #39529702H | Aug 14, 2025 IN VIOLATION | $0 |
| Sep 27, 2023 | Construction CLASS - 2 TIME OF INSPECTION AT 4 STORY ALTERATION ACTIVE SITE OBSERVED EXTERIOR AND INTERIOR WORK IN PROGRESS, UPON FURTHER OBSERVED UNSAFE SCAFFOLD AT EXPOSURE 1 AND 3-MISSING GUARD RAILS, TOE-BOARD, INADEQUATE NETTING #39522192P | Jun 25, 2024 IN VIOLATION | $0 |
| Sep 27, 2023 | Construction CLASS - 2 AT TIME OF MY INSPECTION 4 STORY ALTERATION ACTIVE SITE OBSERVED EXTERIOR AND INTERIOR WORK IN PROGRESS. UPON REQUEST TO SEE DOB APPROVED STRUCTURAL DRAWING, COLD FORM STREEL JOIST SPECIAL ENGINEER REPORT AND M #39522186Z | Jun 25, 2024 IN VIOLATION | $0 |
| Sep 27, 2023 | Unknown CLASS - 2 TIME OF INSPECTION AT 4 STORY ALTERATION SITE OBSERVED EXTERIOR AND INTERIOR WORK IN PROGRESS , UPON FURTHER OBSERVED INADEQUATE HOUSE KEEPING AT EXPOSURE 1, 1ST FLOOR AND EXPOSURE 3 REAR OF THE BUILDING BLOCKI #39522187K | Jun 25, 2024 IN VIOLATION | $0 |
| Jun 16, 2023 | Construction CLASS - 2 OBSERVED INADEQUATE SCAFFOLD WITH MISSING MIDRAILS,UNSAFE PLANKING PLATFORM NOT TIED DOWN IN BC3314.5.5, CREATES HAZARD TO WORKERS OF FALLS FROM HEIGHT OF 35 FEET LEADS TO INJURIES OR FATAL. STOP ALL EXTERIOR W #39517892J | Aug 22, 2023 IN VIOLATION | $0 |
| Sep 16, 2021 | Site Safety CLASS - 1 FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER 33-SSP-C.S. LOG BOOK. NOTED: AT TIME OF MY INSPECTION OF AN ALTERATION TYPE 1,CONSTRUCTION IN PROGRESS AT THE UNDERPINNING STAGE,UPON ENTERIN #35589507L | Mar 15, 2022 IN VIOLATION | $0 |
| Sep 16, 2021 | Construction CLASS - 1 SEC. BC 3301.1.2 NO ADEQUATE FIRE EXTINGUISHERS ON SITE. NOTED: AT TIME OF MY INSPECTION OF AN ALTERATION TYPE 1,4 STY BLDG CONSTRUCTION IN PROGRESS AT THE UNDERPINNING/FOUNDATION PHASE,UPON ENTERING THE SITE,I #35589510M | Mar 15, 2022 IN VIOLATION | $0 |
| Sep 16, 2021 | Unknown CLASS - 2 CONSTRUCTION SUPERINTENDENT FAILED TO PERFORM DUTIES PER CODE. NOTED: AT TIME OF MY INSPECTION OF AN ALT-1,4 STY BLDG FOR WHICH THE ABOVE MENTIONED RESPONDENT IS THE CONSTRUCTION SUPERINTENDENT I OBSERVED THE #35589513H | Mar 15, 2022 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Mar 7, 2024 | PLUMBING BASED ON COMMISSIONERS SUSPENSION NOTIFICATION ON 2/28/2024 INTENDS TO REVOKE ALL PLUMBING APPROVALS AND PERMIT ISSUED UNDER JOB #421623951 DUE TO SUSPENSION OF LICENSE MASTER PLUMBER # 002245 STOP ALL PLUMBING WORK UNDER ABOVE MENTIONED PERMIT IMMEDIATELY. #24-00677 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Jan 8, 2026 | Gas Piping - LL152 FTF-PL-PER Cycle 2, Sub-cycle A (premises is in Community District 1) | Active |
None open.
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)