Brooklyn · Block 4868 · Lot 39 · 11226

308 Linden Boulevard

7 floors · 18 apartments · 14,190 sq ft · built 2021 · class D1 · owner of record: Troy Global Llc

1open violations
$15,525ECB/OATH penalties owed
0HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 68 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 68 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 84 days
Annual
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 17 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 433 days
Next cycle year 2027
Facade inspection report (Cycle 10B) Applies
Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. Agency page

Feb 21, 2028
in 485 days
No Cycle 10 report on record yet

Open violations

ECB / OATH (8) · $15,525 owed
IssuedViolationHearingBalance
Oct 27, 2021Construction CLASS - 1
UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF STOP WORK ORDER.AT TIME OF INSPECTION ON ACTIVE PERMIT 7 STORY NEW BUILDING SITE WITH 6 PARTIAL STOP WORK ORDERS IN EFFECT IN BIS WITH MORE RECENT PARTIAL STOP WORK
#35633052J
Nov 3, 2022
IN VIOLATION
$5,000
Aug 30, 2021Construction CLASS - 2
PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION.NOTED:AT THE TIME OF INSPECTION I OBSERVED PROPOSED 7 STORY NEW BLDG CURRENTLY AT 3RDFL DECK LEVEL.ALSO I OBSERVED CONSTRUCTION FENCE & SIDEWALK SHED IN PL
#35589781Y
Aug 25, 2022
IN VIOLATION
$2,400
Aug 30, 2021Construction CLASS - 1
3307.2.6.3 REQUIREMENTS FOR SIDEWALK MISSING BLIND SPOT MIRROR.NOTE:ATTHE TIME OF MY INSPECTION AT PROPOSED 7 STORY NEW BLDG CURRENTLY AT 3RD FL DECOR WALL.THE FOLLOWING VIOLATING CONDITION I WAS OBSERVED:AT EX
#35589782X
Aug 25, 2022
IN VIOLATION
$625
Aug 24, 2021Construction CLASS - 2
PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATION AT TIME OF INSPECTION OF 7 STORY NB,NO ACTIVE WORK OBSERVED YODOCK BARRIERS PLACED ONSIDEWALK STORED IMPROPERLY AND UNPROTECTED FROM PEDESTRIAN PASSING BY
#35583373H
Mar 16, 2022
IN VIOLATION
$625
Jun 5, 2021Construction CLASS - 1
WORK DOES NOT CONFORM TO APPROVED P.E. CONSTRUCTION DOCUMENTS. AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE JOBSITE OBSERVED: 1),ORTAR USED FOR CMU FROM GROUND LEVEL TO 3RD LEVEL TO BE TYPES DESPITE DRAWING S-0
#35577752R
Mar 21, 2022
IN VIOLATION
$625
Jun 5, 2021Construction CLASS - 1
SEC. BC 3310.7 FAILURE TO PROVIDE APPROVED P.E. DESIGN DRAWINGS. AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE CONSTRUCTION SITE,OBSERVED STEEL STAIRCASE BEING INSTALLED FROM GROUND LEVEL TO 2ND FL. WHILE INSTAL
#35577751P
Oct 13, 2021
IN VIOLATION
$1,250
Jun 5, 2021Construction CLASS - 1
SEC. 2104.6 FAILURE TO PROVIDE MASONRY CMU BLOCK WALL CONSTRUCTION BRACING ACCORDANCE W/TMS 602/ACI 530.1/ASCE 6 SECTION 3.3.E. AS NOTED: ATTIME OF INSPECTION AT AN ACTIVE JOBSITE,OBSERVED ON GROUND LEVEL & 2ND
#35577753Z
Mar 21, 2022
IN VIOLATION
$2,500
Jun 5, 2021Construction CLASS - 1
SEC. 3301.1.2 FAILURE TO PROVIDE FIRE GUARD FOR TORCH OPERATIONS. AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE JOBSITE,OBSERVED HOTWORK/WELDING WAS BEING PERFORMED AT STEEL STAIRCASE BETWEEN GROUND LEVEL & 2ND
#35577755M
Mar 21, 2022
IN VIOLATION
$2,500
DOB (0)

None open.

DOB NOW Safety (1)
IssuedViolationStatus
Sep 11, 2024Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2023 Periodic Inspection Report
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 24, 2026, 6:56 PM ET. BBL 3048680039.

Look up another building