4 floors · 61,700 sq ft · built 1950 · class G1 · owner of record: 310 Company Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 6 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 44 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 44 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 61,700 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 165 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 165 days | Annual filing |
| Energy audit and retro-commissioning (2030) Likely applies Local Law 87 · Calendar year 2030 What this isBuildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 1340). Agency page | Dec 31, 2030 in 1505 days | Next due 2030 |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 23, 2026 | Elevators CLASS - 1 100/M/7 IN SIDE CAR BACK WALL MISSING PROVIDE. #39185829Z | Dec 1, 2026 | $1,250 |
| Aug 16, 2023 | Construction CLASS - 1 AT TIME OF INSPECTION OBSERVED PARKING GARAGE INSTATE OF DISREPAIR CONDITIONS INCLUDING CELLING CONCRETE CRACKS, SPALLING, MISSING CONCRETE THROUGHOUT 1ST TO 4TH FLOOR. ALSO OBSERVED WATER DAMAGE AND REINFORCEM #39092635H | Oct 26, 2023 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 12, 2026 | CONSTRUCTION BOROUGH COMMISSIONER STOP WORK ORDER APPLICATION #M00866401-I1 DUE TO SPECIAL INSPECTOR WITHDRAWAL. #26-01988 | DOB VIOLATION - ACTIVE |
| Aug 29, 2023 | CONSTRUCTION PARTIAL VACATE ORDER.OBSERVED SPALLING CONCRETE AT CEILINGOF CONCRETE SLAB,ENCASED BEAMS AND REBARS EXPOSED; SHORINGS IN CLOSEPROXIMITY IN TRAFFIC LANES.VACATE ENTIRE FLOOR 3 AND 4 OF PARKING GARAGE #LL10601JL | DOB VIOLATION - ACTIVE |
| Aug 28, 2023 | CONSTRUCTION EMERGENCY WORK ORDER FAILURE TO MAINTAIN PARKING STRUCTURE IN SAFE CONDITION.OWNR TO RTAIN NYC REC DDGN(RDP)TO DRCT&SUPERVISE THE IMMED INSTALLATION OF SAFETY MEASURES@ALL FAILD&HAX CNCRETE ELEMENTS #CEU1061OO | DOB VIOLATION - ACTIVE |
| Aug 16, 2023 | CONSTRUCTION AT TIME OF INSPECTION OBSERVED PARKING GARAGE INSTATE OF DISREPAIR CONDITIONS INCLUDING CELLING CONCRETE CRACKS, SPALLING, MISSING CONCRETE THROUGHOUT 1ST TO 4TH FLOOR. ALSO OBSERVED WATER DAMAGE AND REINFORCEMENT/REBAR EXPOSED & SEVERELY ROTTEN. #23-02360 | DOB VIOLATION - ACTIVE |
| Apr 3, 2014 | ELEVATOR #9027/50318N | DOB VIOLATION - ACTIVE |
| Jun 3, 2013 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00458 | DOB VIOLATION - ACTIVE |
| May 3, 2012 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00713 | DOB VIOLATION - ACTIVE |
| Jan 1, 2012 | FAILURE TO BENCHMARK FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4 #00573 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Dec 31, 2024 | Parking Structures FTC-PS-UNSAFE Unsafe report of parking structures filed. | Active |
| May 20, 2019 | Elevators EVCAT5 | Active |
| May 20, 2019 | Elevators EVCAT5 | Active |
| Jun 3, 2013 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| May 3, 2012 | Benchmarking - LL84 FTF-EN-BENCH | Active |
| Jan 1, 2012 | Benchmarking - LL84 FTF-EN-BENCH | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 12, 2026 | DOB | CONSTRUCTION: BOROUGH COMMISSIONER STOP WORK ORDER APPLICATION #M00866401-I1 DUE TO SPECIAL INSPECTOR WITHDRAWAL. | Open |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 17, 2026, 5:53 PM ET. BBL 1013400044.