Brooklyn · Block 6815 · Lot 57 · 11229

3065 Nostrand Avenue

1 floors · 2 apartments · 2,025 sq ft · built 1945 · class S2 · owner of record: Nostrand Cmp, Llc

14open violations
$11,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
425dto Gas piping inspection (2027 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 60 days
Keep the report on file (not filed with DOB)
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 304 days
Required only if the owner doesn't live there
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 15 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 425 days
Next cycle year 2027

Open violations

ECB / OATH (7) · $11,250 owed
IssuedViolationHearingBalance
Oct 3, 2023Construction CLASS - 2
WORK WITHOUT A PERMIT AT REAR YARD APPOX 18'X24'12' PERGOLA WITH ELECTRIC LIGHTS , AT 2ND FLOORS ENTRANCE AND STRUCTURE WITH ROOF AND FRAMING WITH PARTIAL PLYS INSTALLED, 4 A/C UNITS INSTALLED WITHOUT A PERMITS
#39096338J
Dec 9, 2025
DEFAULT
$6,250
Mar 25, 2021Construction CLASS - 1
WORK WITHOUT A PERMIT, GAS, WATER AND WASTE PIPE INSTALLED THROUGHOUT SECOND FLOOR 2 NEW TOILET ROUGHS NEW SHOWER PAN AND SHOWER BODY WITH MULTIPLE SINKS, OBTAIN PERMIT
#39038327Z
Oct 13, 2022
IN VIOLATION
$2,500
Mar 25, 2021Construction CLASS - 1
FAILURE TO MAINTAIN, PROHIBITED MATERIALS. PVC USED FOR WASTE AND VENT PIPE THROUGHOUT 2ND FLOOR. PVC PROHIBITED IN MIXED USED BUILDINGS AS PER PC 702.1, REPAIR AND/REPLACE
#39038328K
Oct 13, 2022
IN VIOLATION
$625
Mar 25, 2021Unknown CLASS - 2
ELECTRICAL WORK W/O A PERMIT. ON 3-25-21 AT 1:45PM,I OBSERVED,NEW BRANCH CIRCUIT WIRING. NEW # 6AWG FDR INSTALLED 1 100AMPS PANEL 12/24 CIRCUIT. NEW FIXTURES,SWITCHES,RECEPTACLES. CENTRAL AIR UNIT INSTALLED 2ND
#35547708M
Oct 13, 2022
IN VIOLATION
$0
Mar 25, 2021Construction CLASS - 1
WORKING AGAINST A STOP WORK ORDER, PIPING INSTALLED FOR KITCHEN AND BATHROOMS WHILE PROPERTY WAS UNDER STOP WORK ORDER, COMPLY WITH STOP WORK ORDER
#39038321H
Oct 13, 2022
IN VIOLATION
$0
Feb 18, 2021Construction CLASS - 2
FAILURE TO MAINTAIN VIOLATING CONDITION WAS OBSERVED ON GROUND LEVEL LOCATION BEING USED AS DENTAL OFFICE.OBSERVED 3X3' PIECE OF SHEETROCK CEILING THAT FELL DUE TO ILLEGAL CONST ON2FL.ROM IN WHICH DAMAGE HAS OC
#35441776Z
Feb 4, 2022
IN VIOLATION
$625
Feb 12, 2021Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER, VARIOUS LEAKS IN CEILING OF DENTIST OFFICE LEAKS ARE COMING FROM VACANT SPACE ON SECOND FLOOR. MAN FROM SECOND FLOOR DENIED ACCESS. THERE IS WORK ONGOING I
#39036192L
Jun 16, 2021
IN VIOLATION
$1,250
DOB (3)
IssuedViolationStatus
Jun 23, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00457
DOB VIOLATION - ACTIVE
Jun 23, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00458
DOB VIOLATION - ACTIVE
May 12, 2021FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00299
DOB VIOLATION - ACTIVE
DOB NOW Safety (3)
IssuedViolationStatus
Jun 23, 2021AEUHAZ FTC-AEU-HAZ
Active
Jun 23, 2021AEUHAZ FTC-AEU-HAZ
Active
May 12, 2021AEUHAZ FTC-AEU-HAZ
Active
HPD (1) · C 0 · B 1 · A 0
IssuedClassViolationCorrect by
Jan 10, 2020B§ 27-2005 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF EXPOSED WIRE CONECTING BETWEEN TWO FUSE BOXES AT NORTH WALL AT CELLARFeb 14, 2020

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 1, 2026, 12:50 PM ET. BBL 3068150057.

Look up another building