Manhattan · Block 763 · Lot 45 · 10018

306 West 40 Street

4 floors · 4,800 sq ft · built 1930 · class K4 · owner of record: Nyc One Holding Llc

59open violations
$256,715ECB/OATH penalties owed
0HPD class C (immediately hazardous)
48dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 48 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 48 days
Keep the report on file (not filed with DOB)

Open violations

ECB / OATH (32) · $256,715 owed
IssuedViolationHearingBalance
Aug 10, 2026Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE IN PLACE. UPON REVIEW OF DEPARTMENT RECORDS, IT WAS DETERMINED THAT CONSTRUCTION FENCE PERMIT M01178407-I1-FN EXPIRED ON 04/30/2026. RENEW THE REQUIRED PERMIT.
#39557736Y
Oct 15, 2026
DEFAULT
$1,280
Aug 10, 2026Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED IN PLACE WITHOUT THE REQUIRED PARAPET INFORMATION PANEL, CONTRARY TO BC 3301.9.2. PROVIDE AND MAINTAIN THE REQUIRED SIDEWALK SHED PARAPET INFORMATION PANEL.PROVIDE
#39557735M
Oct 15, 2026
DEFAULT
$1,280
Aug 10, 2026Construction CLASS - 2
AT TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE NOT PROPERLY MAINTAINED AND WITHOUT REQUIRED VIEWING PANELS, CONTRARY TO BC 3307.7.3. ADVERTISING WAS POSTED ON THE FENCE CONTRARY TO BC 3301.9.7, MAINTAIN FEN
#39557737X
Oct 15, 2026
DEFAULT
$1,030
May 12, 2026Construction CLASS - 2
OBSERVED EXPO.1 SWS DECK NOT TIGHT TO FACADE CREATED OPENING HAZARD CREATED STRIKE FROM ABOVE DEBRIS OR MATERIAL.BC3307.6.4.5 STIPULATES GAPS BETWEEN DECK SWS AND FACE OF BUILDING BE SEALED WITH MATERIAL SUFFIC
#39188182K
Jul 16, 2026
DEFAULT
$6,250
May 5, 2026Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. DOBVIO23-02230 IN CONNECTION WITH 39091608H ISSUED BY BADGE 2748,REVIEWED DEPARTMENT RECORDS NO PE REPORT SUBMITTED FOR VIO23-02230,NO CFC FOR ECB3909
#39187303N
Jul 9, 2026
DEFAULT
$12,500
May 5, 2026Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH COMMISSIONER'S ORDER. VIO24-02958-DISPOSITION IN COMPLAINT 1682037 NOTES WOOD SHORING SYSTEM STABILIZING BUILDING COMPROMISED DUE TO FIRE,PE REPORT REQUESTED, REVEIWED DEPA
#39187304P
Jul 9, 2026
DEFAULT
$12,500
Feb 27, 2026Construction CLASS - 2
AT TIME OF INSPECTION 5:30 AM, OBSERVED DEFECTIVE LIGHTING AT SIDEWALK SHED EXPS.1, CREATING DARK CONDITION. HAZARDOUS TO TENANTS/PEDESTRIANS, RISK OF SLIP/TRIP/FALL AND CRIMINAL ACTIVITY. NO PREVENTIVE MEASURE
#39551013N
May 7, 2026
DEFAULT
$10,000
Nov 21, 2025Construction CLASS - 1
FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39091608H ISSUED ON 08/02/2023 FOR FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER, REPAIR AND/REPLACE
#39167991H
Jan 29, 2026
DEFAULT
$25,000
Nov 21, 2025Construction CLASS - 2
FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39088489R ISSUED ON 06/13/2023 FOR FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER, FILE A CERTIFICATE OF CORRECTION
#39167989Z
Jan 29, 2026
DEFAULT
$6,250
Nov 21, 2025Construction CLASS - 1
FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39141008R ISSUED ON 03/10/2025 FOR FAILURE TO MAINTAIN BUILDING WALL(S) OR APPURTENANCES., MAINTAIN EXTERIOR BUILDING WALL
#39167990X
Jan 29, 2026
DEFAULT
$25,000
Apr 1, 2025Construction CLASS - 2
AT TIME OF INSPECTION IN RESPONSE TO COMPLAINT I OBSERVED UNDERSIDE OF SIDEWALK SHED A NOT ILLUMINATED AS PER 3307.6.4.8. THIS CREATES A HAZARDOUS CONDITION FOR PUBLIC WALKING UNDERNEATH WHILE DARK AND NOT BEIN
#39538564N
Jun 5, 2025
DEFAULT
$10,000
Mar 25, 2025Construction CLASS - 2
FAILED TO PROVIDE SIDEWALK SHED'S PARAPET INFORMATION PANEL CONTRARY WITH BC-3301.9.2, CREATING HAZARDOUS AS FDNY HARD TO LOCATED IN EMERGENCY. WHERE A SIDEWALK SHED PARAPET INFORMATION PANEL SHALL BE POSTED IN
#39538350H
Jun 8, 2026
IN VIOLATION
$1,250
Mar 10, 2025Construction CLASS - 1
OBSERVED AT EXPOSURE#4 CHIMNEY IN A STATE OF DISREPAIR WITH LOOSE AND MISSING BRICKS., MAINTAIN EXTERIOR BUILDING WALL; REPAIR FACADE
#39141008R
May 15, 2025
DEFAULT
$25,000
Mar 10, 2025Construction CLASS - 1
FAILURE TO COMPLY WITH A COMMISSIONERS ORDER FOR NO SUBMITTAL OF AN ENGINEERS REPORT AS REQUESTED VIA DOB VIOLATION VIO24-02958, COMPLY WITH COMMISSIONER'S ORDER
#39141009Z
May 15, 2025
DEFAULT
$12,500
Sep 15, 2023Construction CLASS - 2
FAILURE TO MAINTAIN BUILDING IN A CODE-COMPLIANT MANNER. AT THE TIME OF INSPECTION, I OBSERVED EXCESSIVE AMOUNT OF DEBRIS BEHIND THE CONSTRUCTION SITE FENCE. DEBRIS CONSIST OF PLASTIC BOTTLES, PLASTIC CANS, BEE
#39094914J
Apr 2, 2024
DEFAULT
$3,125
Sep 15, 2023Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT ON SITE- EXPIRED PERMIT. AT THE TIME OF INSPECTION, I OBSERVED CONSTRUCTION SITE FENCE UNDER JOB # M00039537-I1-FN EXP. 3/6/2020 IS EXPIRED AND NOT RENEWED IN DOB RECORDS., RENE
#39094916N
Dec 12, 2024
IN VIOLATION
$625
Sep 15, 2023Construction CLASS - 2
TEMPORARY CONSTRUCTION EQUIPMENT ON SITE- EXPIRED PERMIT. AT THE TIME OF INSPECTION, I OBSERVED CONSTRUCTION SIDEWALK SHED UNDER JOB # M00640521-I1-SH EXP. 1/21/2023 IS EXPIRED AND NOT RENEWED IN DOB RECORDS.,
#39094915L
Nov 30, 2023
DEFAULT
$6,250
Aug 2, 2023Construction CLASS - 1
OBSERVED PARAPET WALL AT EXPO # 04 EXTREME DISREPAIR AND MASONRY CHIMNEY TOP PARTIALLY COLLAPSED WITH LEANING & FURTHER COLLAPSE LIKELY. ALSO OBSERVED SECTION OF BRICKS MISSING WITH VERTICAL CRACK ON EXTERIOR W
#39091608H
Oct 12, 2023
DEFAULT
$12,500
Jun 13, 2023Construction CLASS - 1
AT TIME OF INSPECTION, SIDEWALK SHED AT EXPOSURE 1 OF PREMISES BUILT WITHOUT PERMIT, OBTAIN PERMIT; OBTAIN SIDEWALK SHED PERMIT
#39088490Y
May 2, 2024
IN VIOLATION
$2,500
Jun 13, 2023Construction CLASS - 1
AT TIME OF INSPECTION, 4 X 4 WOOD PANEL AT CONSTRUCTION FENCE DETACHED AND OPEN AND FRONT DOOR OF PREMISES OPEN, LEAVING VACANT BUILDING OPEN TO THE PUBLIC, REPAIR AND/REPLACE; SEAL BUILDING AND CONSTRUCTION FE
#39088489R
May 2, 2024
IN VIOLATION
$1,250
Jun 13, 2023Construction CLASS - 1
AT TIME OF INSPECTION, CONSTRUCTION FENCE AT EXPOSURE 1 OF PREMISES BUILT WITHOUT PERMIT, OBTAIN PERMIT; OBTAIN FENCE PERMIT
#39088491X
May 2, 2024
IN VIOLATION
$2,500
Mar 3, 2023Construction CLASS - 2
AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE #1 OF THE BUILDING WITHOUT SIGNS OR PROJECT INFORMATION PANEL ON THE SHED PARAPET TO INDICATE THE NAME AND THE CONTACT INFORMATION OF THE OWN
#39513748R
May 11, 2023
DEFAULT
$6,250
Mar 3, 2023Construction CLASS - 2
AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE #1 OF THE BUILDING, UPON REVIEW THE DEPARTMENT RECORDS TO VERIFY COMPLIANCE IT SHOWS THAT THE SHED PERMIT HAD EXPIRED SINCE 01212023RENEW PER
#39513746N
May 11, 2023
DEFAULT
$3,125
Mar 3, 2023Construction CLASS - 2
AT TIME OF INSPECTION I OBSERVED CONSTRUCTION FENCE INSTALLED ON EXPOSURE #1 OF THE BUILDING, UPON REVIEW THE DEPARTMENT RECORDS TO VERIFY COMPLIANCE IT SHOWS THAT THE FENCE PERMIT HAD EXPIRED SINCE 03062020REN
#39513747P
May 11, 2023
DEFAULT
$6,250
Mar 3, 2023Construction CLASS - 1
AT TIME OF INSPECTION I OBSERVED SIDEWALK SHED INSTALLED ON EXPOSURE #1 WITH INOPERABLE LIGHT BULBS UNDERSIDE THE SHED TO BRING ILLUMINATION FAILURE TO PROVIDE LIGHTING CREATES UNSAFE AND MUGGING CONDITION TO
#39513745L
May 11, 2023
DEFAULT
$12,500
Mar 3, 2022Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION NOTED:FACADE EXPOSURE#4 IN STATE OF DISREPAIR WITH MISSING AND OR DISLODGED BRICKS WITH BRICK CHIMNEY LEANING OUT OF PLUMB.REM:COMPLY
#35636144K
Jun 2, 2022
DEFAULT
$12,500
Mar 3, 2022Construction CLASS - 1
FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATION#39050455P ISSUED ON 11/3/21 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01.REM:COMPLY WITH COMMISSIO
#35567964J
Jun 2, 2022
DEFAULT
$6,250
Dec 16, 2021Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.AT TIME OF INSPECTION OBSERVED 4 STORY CLASS - 3 BUILDING NFF STRUCTURE CURRENTLY UNOCCUPIED AND FULL STATE OF DISREPAIR NOT MAINTAINED PROPERLY ALL EXP SAM
#35636112X
Mar 17, 2022
DEFAULT
$12,500
Nov 3, 2021Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED 4 STORY, CLASS 3 NFP STRUCTURE CURRENTLY UNOCCUPIED AND IN FULL STATE OF DISREPAIR WITH ENTIRE EXPOSURE #4 SHORED WITH COMBUSTIBLE MATERIALS (WOOD
#39050449Z
Dec 23, 2021
DEFAULT
$6,250
Nov 3, 2021Construction CLASS - 1
WORK WITHOUT A PERMIT. OBSERVED 4 STORY, CLASS 3 NFP STRUCTURE CURRENTLY UNOCCUPIED AND IN FULL STATE OF DISREPAIR WITH ENTIRE EXPOSURE 4 (40' HIGH X 40LF IN LENGTH) SHORED WITH COMBUSTIBLE MATERIALS (WOOD) AND
#39050455P
Dec 23, 2021
DEFAULT
$12,500
Mar 20, 2013Unknown CLASS - 1
ELECTRICAL WORK W/O A PERMIT. TWO ELECTRICAL SIGNS: NO APP ON FILE FO RTWO ELECTRICAL SIGN. "OPEN 24 HRS" REMEDY: OBTAIN PERMIT.
#35009388Y
May 9, 2013
DEFAULT
$0
Mar 20, 2013Unknown CLASS - 1
UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMEN APPARATUS,MATERIALS,DEVICES,APPLIANCES OR WRITING IN USE.AT THE ENTIRE PARKING LOT:DEFECTIVE WIRING USED FLEXIBLE CORDS/CABLE NOT PROTECTED.FLEX CORDS/CABLE NOT
#35009387M
May 9, 2013
DEFAULT
$0
DOB (17)
IssuedViolationStatus
Feb 11, 2026CONSTRUCTION
FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AS NOTED AT TI ME OF INSPECTION,I OBSERVED AT EXP1 SAGGING/CORRODED LENTIL ON 2ND&3RD FLOORS.DAMAGED MORTAR JOINTS AT LINTELS.EXP4 CHIMNEY DISINTERGRATING,M ISSING COPING STONE,SPALLING STUCCO AT SEVERAL LOCATIONS.MISSING BRICK AT NW CORNER OF
#SR0403RF
DOB VIOLATION - ACTIVE
Nov 15, 2024CONSTRUCTION
OWNER TO HIRE NYPSE TO SUBMIT REPORT TO ERTINSPECTIONS@BUILDINGS.NYC.GOV WITH IN 3 DAYS ADDRESSING ALL CONDITIONS W/PLANS, PHOTOS, RECOMMENDING TIME FRAME AND REPAIRS TO BE COMPLETED.
#24-02958
DOB VIOLATION - ACTIVE
Dec 13, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00004
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00203
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00202
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00204
DOB VIOLATION - ACTIVE
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00205
DOB VIOLATION - ACTIVE
Sep 15, 2023IMMEDIATE EMERGENCY

#17873
DOB VIOLATION - ACTIVE
Sep 15, 2023IMMEDIATE EMERGENCY
REPAIR CONSTRUCTION SITE FENCE DOOR AT FRONT EXPOSURE 1 AND SECURE THE SITE
#17873
DOB VIOLATION - ACTIVE
Aug 2, 2023CONSTRUCTION
OBSERVED PARAPET WALL AT EXPO # 04 EXTREME DISREPAIR AND MASONRY CHIMNEY TOP PARTIALLY COLLAPSED WITH LEANING & FURTHER COLLAPSE LIKELY. ALSO OBSERVED SECTION OF BRICKS MISSING WITH VERTICAL CRACK ON EXTERIOR WALL AT THE CORNER OF EXPO # 01 & 04.
#23-02230
DOB VIOLATION - ACTIVE
Mar 16, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00027
DOB VIOLATION - ACTIVE
Feb 2, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00020
DOB VIOLATION - ACTIVE
Feb 2, 2022FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00021
DOB VIOLATION - ACTIVE
Jan 15, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00540
DOB VIOLATION - ACTIVE
Jan 15, 2014FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00539
DOB VIOLATION - ACTIVE
Jun 23, 2010ZONING

#MTF07VP
DOB VIOLATION - ACTIVE
Sep 25, 2002CONSTRUCTION

#MTF03RNS
DOB VIOLATION - ACTIVE
DOB NOW Safety (13)
IssuedViolationStatus
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Mar 17, 2026AEUHAZ FTC-AEU-HAZ
Active
Dec 13, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
Mar 16, 2022AEUHAZ FTC-AEU-HAZ
Active
Feb 2, 2022AEUHAZ FTC-AEU-HAZ
Active
Feb 2, 2022AEUHAZ FTC-AEU-HAZ
Active
Jan 15, 2014AEUHAZ FTC-AEU-HAZ
Active
Jan 15, 2014AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Aug 10, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE IN PLACE. UPON REVIEW OF DEPARTMENT RECORDS, IT WAS DETERMINED THAT CONSTRUCTION FENCE PERMIT M01178407-I1-FN EXPIRED ON 04/30/2026. RENEW THE REQUIRED PERMIT.Open
Aug 10, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED SIDEWALK SHED IN PLACE WITHOUT THE REQUIRED PARAPET INFORMATION PANEL, CONTRARY TO BC 3301.9.2. PROVIDE AND MAINTAIN THE REQUIRED SIDEWALK SHED PARAPET INFORMATION PANEL.PROVIDEOpen
Aug 10, 2026ECBConstruction: AT TIME OF INSPECTION, OBSERVED CONSTRUCTION FENCE NOT PROPERLY MAINTAINED AND WITHOUT REQUIRED VIEWING PANELS, CONTRARY TO BC 3307.7.3. ADVERTISING WAS POSTED ON THE FENCE CONTRARY TO BC 3301.9.7, MAINTAIN FENOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 13, 2026, 5:41 PM ET. BBL 1007630045.

Look up another building