Bronx · Block 5714 · Lot 159 · 10463

306 West 232 Street

7 floors · 27,875 sq ft · built 2025 · class W3 · owner of record: Panstar Realty Llc

25open violations
$184,180ECB/OATH penalties owed
0HPD class C (immediately hazardous)
62dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 62 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 62 days
Keep the report on file (not filed with DOB)
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 114 days
No Cycle 10 report on record yet
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 27,875 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 183 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 183 days
Annual filing

Open violations

ECB / OATH (25) · $184,180 owed
IssuedViolationHearingBalance
Jul 20, 2026Unknown CLASS - 2
AT TIME OF INSPECTION, 7-STORY SCHOOL BUILDING OBSERVED WITH DUMPSTER STORAGE ZONE AT EXPOSURE 1 NOT PROPERLY ENCLOSED. REQUIRED 4-FOOT SOLID BARRIER AND 4-FOOT CHAIN-LINK FENCING WERE NOT PROVIDED AROUND THE D
#39556818N
Oct 2, 2026
DEFAULT
$2,530
Jun 18, 2026Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENTS. ASNOTED: AT TIME OF INSPECTION AT A JOBSITE OF A PROPOSED 7 STORY BUILDING ALREADY AT THE BULKHEAD LEVEL. OBSERVED FROM THE BULKHEAD LEVEL TO
#35726440Y
Sep 4, 2026
DEFAULT
$12,500
Jun 18, 2026Construction CLASS - 1
FAILURE TO INSTITUTE SAFETY EQUIP MEASURES OR TEMPORARY CONSTRUCTION "IMPROPER GUARDRAIL". AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE JOBSITE OF A PROPOSED 7 STORY BUILDING ALREADY AT THE BULKHEAD LEVEL. OBSE
#35726439R
Sep 4, 2026
DEFAULT
$25,000
May 18, 2026Unknown CLASS - 2
7-STORY NEW BUILDING TOPPED OUT, I OBSERVED EXPOSURE #1 WHERE A DELIVERY TRUCK WAS USED FOR WINDOW DELIVERY AND A FORKLIFT WAS LIFTING EQUIPMENT OVER A PEDESTRIAN WALKWAY. REVIEW OF DOT RECORDS AND ONSITE DOCUM
#39554263J
Jan 29, 2027
PENDING
$2,500
Apr 10, 2026Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENT. AS NOTED: AT TIME OF INSPECTION AT A JOBSITE OF A PROPOSED 7 STORY BUILDING ALREADY AT THE BULKHEAD LEVEL. OBSERVED FROM THE BULKHEAD LEVEL TO
#35726462P
Dec 18, 2026
PENDING
$2,500
Mar 4, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION OF A 7-STORY NEW BUILDING, OBSERVED SUPPORTED PIPE SCAFFOLDS ERECTED AT ALL EXPOSURES THAT WERE NOT MAINTAINED IN ACCORDANCE WITH CODE. SCAFFOLDS WERE NOT FULLY PLANKED AND WERE MISSIN
#39551217P
May 15, 2026
DEFAULT
$10,000
Mar 4, 2026Unknown CLASS - 1
AT THE TIME OF INSPECTION OF A 7-STORY NEW BUILDING, ACTIVE JOBSITE WITH SUPPORTED PIPE SCAFFOLDS INSTALLATION OPERATION ONGOING UPON REQUESTING ORIENTATION FOR THE WORKERS INSTALLING PIPE SCAFFOLDS NON WAS PRE
#39551210M
May 15, 2026
DEFAULT
$25,000
Mar 4, 2026Unknown CLASS - 2
AT THE TIME OF INSPECTION, ACTIVE JOBSITE I OBSERVED PIPE SCAFFOLDS NOT AS PER CODE WHILE USING, UPON REQUEST INSTALLATION INSPECTION REPORT PRIOR TO USE AS PER CODE 3314.4.3.3 NON WAS ONSITE OR MADE AVAILABLE
#39551221H
May 15, 2026
DEFAULT
$10,000
Mar 4, 2026Construction CLASS - 1
AT THE TIME OF INSPECTION OF A 6-STORY NEW BUILDING, ACTIVE CONSTRUCTION SITE I NOTICED INADEQUATE HOUSEKEEPING 1ST FLOOR TO ROOF AND SIDEWALK SHED DECK NOT FREE OF DEBRIS, THIS CREATES UNSAFE WORKING CONDITION
#39551206J
May 15, 2026
DEFAULT
$12,500
Feb 3, 2026Construction CLASS - 2
28-103.8. FAILURE TO MAINTAIN EMBED SAFETY STRAPS INSTALLATION INSPECTION LOG BOOK ON SITE. AS NOTED: AT TIME OF INSPECTION ON AN ACTIVE JOBSITE OF A PROPOSED 7 STORY BUILDING ALREADY AT THE BULKHEAD LEVEL OF A
#35726553K
Apr 17, 2026
DEFAULT
$6,250
Feb 3, 2026Construction CLASS - 1
FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING PER SECTION REQUIREMENT. AS NOTED: AT TIME OF INSPECTION AT A JOBSITE OF A PROPOSED 7 STORY BUILDING ALREADY AT THE BULKHEAD LEVEL. OBSERVED FROM THE 1ST FLOOR LEVEL MI
#35726554M
Apr 17, 2026
DEFAULT
$12,500
Feb 3, 2026Construction CLASS - 1
FAILURE TO INSTITUTE SAFETY EQUIP MEASURES OR TEMPORARY CONSTRUCTION "IMPROPER GUARDRAILS". AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE JOBSITE OF A PROPOSED 7 STORY BUILDING ALREADY AT THE ROOFTOP/BULKHEAD LE
#35726552Z
Apr 17, 2026
DEFAULT
$25,000
Dec 26, 2025Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION WITH THE DEPARTMENT OF BUILDING. FAILURE TO FILE COC WITH THE DOB. REMEDY: FILE A CERTIFICATE OF CORRECTION FILE CERTIFICATE OF CO
#39548500N
May 1, 2026
DEFAULT
$6,250
Oct 28, 2025Unknown CLASS - 2
7-STORY PROPOSED NEW BUILDING,ACTIVE JOBSITE DURING MY INSPECTION I OBSERVED PIPE SCAFFOLDS ERECTED EXP#2-3 NOT MAINTAINER AS PER CODE 3314.1 PIPE SCAFFOLD ERECTED EXP#2-3 NOT FULLY PLANK MISSING,TOE BROAD,MISS
#39546402K
Dec 29, 2026
DEFAULT
$10,000
Sep 24, 2025Construction CLASS - 1
AT TIME OF INSPECTION OF A 7-STORY NEW PROPOSED BUILDING,ACTIVE CONSTRUCTION SITE DURING MY INSPECTION I OBSERVED HOUSEKEEPING NOT MAINTAIN AS PER CODE DEBRIS AND MATERIALS BLOCKING WALKWAY FOR WORKERS AND EXP#
#39545281Z
Apr 3, 2026
IN VIOLATION
$1,250
May 13, 2025Unknown CLASS - 2
OBSERVED 2ND STORY SLAB POURED OF A 7 STORY NB WITH NO OHP FOR ADJ.PROPERTY EGRESS AND YARD EXP2,BC3309.1 STIPULATES PROTECTION REQUIRED FOR ADJ.PUBLIC AND PRIVATE PROPERTY, INCLUDING PERSONS THEREON, SHALL BE
#39540219P
Jan 4, 2027
PENDING
$10,000
Mar 11, 2025Construction CLASS - 1
3301.12 PRE-SHIFT SAFETY MEETINGS. AT TIME OF INSPECTION OF A 7-STORY PROPOSED NEW BUILDING, ACTIVE JOBSITE .COMPONENT PERSON PRESENT ONSITE,I OBSERVED 6-WORKERS ONSITE. UPON REQUESTING COMPONENT PERSON PRE-SHI
#39537872K
Feb 12, 2026
IN VIOLATION
$1,250
Dec 19, 2024Construction CLASS - 3
TEMPORARY CONSTRUCTION FENCING UNDER DOB PERMIT# X00776731 BEING EXTENDED UP TO EIGHT FEET HIGH IN CONTRARY TO APPROVED PLANS (EQ-022.00)., CONFORM WORK TO APPROVED CONSTRUCTION DOCUMENTS/AMENDMENTS
#39133357P
Mar 7, 2025
DEFAULT
$500
Jun 14, 2024Unknown CLASS - 2
3303.14 AT A CLOSED FOUNDATION JOBSITE.A LARGE AMOUNT OF STAND STILL WATER AT OPEN EXCAVATION AREA ACCUMULATING.AS PER SECTION 3303.14-3303.14.5.DEWATERING AT CONSTRUCTION SITE EXCAVATION SHALL BE DRAINED.THIS
#39529620Y
Mar 5, 2026
IN VIOLATION
$1,250
Apr 12, 2024Construction CLASS - 2
TEMPORARY CONSTRUCTION FENCING UNSTABLE POST AT EXPOSURE#2 LEANING OUTWARDS., COMPLY WITH CODE
#39111570R
Nov 5, 2026
DEFAULT
$5,000
Jan 8, 2024Construction CLASS - 2
PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. AT TIME OF INSPECTION I OBSERVED INADEQUATE MATERIAL AND MACHINERY STORED IN OPEN SPACE MATERIALS STORED HIGHER THEN BARRIERS. REMEDY: COMPLY WITH CODE.
#35581295M
May 3, 2024
IN VIOLATION
$2,400
May 5, 2023Construction CLASS - 1
REQUIRED MEANS OF EGRESS. AT TIME OF INSPECTION I OBSERVED WOOD LADDER USED FOR EGRESS NOT PROPERLY SECURED AND WITH STEP HEIGHT INADEQUATE AND LARGE SPACES IN BETWEEN STEPS CREATING A HAZARDOUS CONDITION FOR
#39516224J
Dec 15, 2023
IN VIOLATION
$0
May 5, 2023Construction CLASS - 1
STANDING WATER. AT TIME OF INSPECTION I OBSERVED STANDING WATER APPROX. 4 INCHES DEEP THROUGHOUT JOBSITE CREATING A HEALTH HAZARD FROM MOSQUITOES AND OTHER INSECTS AND RODENTS ALSO CREATING A SLIP AND FALL HAZA
#39516225L
Jul 21, 2023
IN VIOLATION
$0
Mar 6, 2023Construction CLASS - 1
AT THE TIME OF INSPECTION, OBSERVED DAMAGED SIDEWALK AT EXPOSURE 1, REAR YARD PAVEMENT FOR EXP2 PROPERTY (3147 TIBBETT AVE) AND SEPARATION BETWEEN ASPHALT PAVING AND CURB AT EXPOSURE 4 PARKING LOT(3130 IRWIN AV
#39513826N
Feb 27, 2024
IN VIOLATION
$0
Mar 14, 2022Construction CLASS - 2
JOB SITE FENCE NOT CONSTRUCTED OR MAINTAINED PURSUANT TO SUBSECTION. I OBSERVED MISSING PANELS FROM THE FENCE AT EXPOSURE #3 AND EXPOSURE #4, COMPLY WITH CODE
#39058006X
Sep 23, 2022
IN VIOLATION
$0
DOB (1)
IssuedViolationStatus
Oct 4, 2023FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#01437
DOB VIOLATION - ACTIVE
DOB NOW Safety (1)
IssuedViolationStatus
Oct 4, 2023AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Jul 20, 2026ECBUnknown: AT TIME OF INSPECTION, 7-STORY SCHOOL BUILDING OBSERVED WITH DUMPSTER STORAGE ZONE AT EXPOSURE 1 NOT PROPERLY ENCLOSED. REQUIRED 4-FOOT SOLID BARRIER AND 4-FOOT CHAIN-LINK FENCING WERE NOT PROVIDED AROUND THE DOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 30, 2026, 10:29 AM ET. BBL 2057140159.