Bronx · Block 2303 · Lot 3 · 10454

306 Alexander Avenue

3 floors · 9 apartments · 3,359 sq ft · built 1881 · class C1 · owner of record: Alexander Bricks, Llc

2open violations
$34,687ECB/OATH penalties owed
2HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 64 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 64 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 80 days
Annual
Gas piping inspection (2028 cycle) Likely applies
Local Law 152 · During 2028
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 1 is on the 2028 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2028
in 795 days
Next cycle year 2028

Open violations

ECB / OATH (7) · $34,687 owed
IssuedViolationHearingBalance
Dec 20, 2021Construction CLASS - 1
BC 3307.7 JOBSITE FENCE NOT CONSTRUCTED OR MAINTAINED AS PER CODE AT TIME OF INSPECTION OF 4 STORY ALT 1,OBSERVED CONSTRUCTION FENCE INSTALLED AT EXP#1 NOT AS PER CODE.OBSERVED THAT THE SWING GATE TO ENTIRE THE
#35636927R
Mar 18, 2022
DEFAULT
$6,250
Dec 20, 2021Construction CLASS - 2
BC 3314.4 SUPPORTED PIPE SCAFFOLD NOT INSTALLED,MAINTAINED AS PER CODEAT TIME OF INSPECTION OF 4 STORY ALT 1,OBSERVED SUPPORTED PIPE SCAFFOLD NOT INSTALLED AS CODE.SUPPORTED PIPE SCAFFOLD HAS LOOSE PLANKS,PLANK
#35636928Z
Mar 18, 2022
DEFAULT
$3,125
Dec 20, 2021Construction CLASS - 1
FAILURE TO PROVIDE PEDESTRIAN PROTECTION FOR SIDEWALK AT TIME OF INSPECTION OF 4 STORY ALT 1,OBSERVED AT EXP#1 SUPPORTED PIPE SCAFFOLD APPROX.50FT HIGH FROM GROUND,ALSO OBSERVED NO SIDEWALK SHED OR ANY OVERHEAD
#35636929K
Mar 18, 2022
DEFAULT
$12,500
Feb 22, 2021Unknown CLASS - 1
RESPONDENT FAILED TO ENSURE THAT EACH CONSTRUCTION OR DEMOLITION WORKER WORKING/ENGAGED AT THE SITE SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER BC 3321.1 & HAS AN OSHA 30HRS CLASS OR A 100HRS TRAINING PR
#35540707Z
Jan 28, 2022
IN VIOLATION
$1,250
Feb 22, 2021Unknown CLASS - 1
SEC. 28-204.1.1 RESPONDENT FAILED TO ENSURE THAT EACH CONSTRUCTION OR DEMOLITION WORKER WORKING/ENGAGED AT SITE SUCCESSFULLY COMPLETED THE REQUIRED TRAINING UNDER BC 3321.1 & HAS AN OSHA 30HRS CLASS OR 100HRS
#35540705P
Jan 28, 2022
IN VIOLATION
$1,250
Dec 8, 2020Site Safety CLASS - 1
FAILURE TO DESIGNATE AND/OR HAVE A CONSTRUCTION SUPERINTENDENT PRESENTAT SITE AS REQUIRED. NOTED:ONGOING CONST WORK UNDER APPL#220593472 HASNO SUPER FOR WORK OBSERVED-REMOVAL OF ALL EXISTING WOOD JOIST,REPLACED
#35508208Y
Jun 24, 2022
IN VIOLATION
$10,000
Dec 8, 2020Construction CLASS - 2
FAILURE TO PROVIDE APPROVED/ACCEPTED CONSTRUCTION DOCUMENTS. NOTED:APPROVED PLANS FOR WORK UNDER APPL#220593472 PROVIDED WERE INCOMPLETE SET,DIRTY,SOILED UNABLE TO READ,MISSING SHEETS. REMEDY:"STOP ALL WORK" IM
#35508209X
Jun 24, 2022
IN VIOLATION
$312
DOB (0)

None open.

DOB NOW Safety (0)

None open.

HPD (2) · C 2 · B 0 · A 0
IssuedClassViolationCorrect by
Nov 6, 2023CApt BSMT · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT BSMT, 1st APARTMENT FROM EAST AT SOUTHNov 20, 2023
Nov 6, 2023CApt BSMT · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT BSMT, 1st STORY, 1st APARTMENT FROM EAST AT SOUTHNov 20, 2023

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 28, 2026, 10:13 AM ET. BBL 2023030003.