Brooklyn · Block 8674 · Lot 23 · 11235

3052 Brighton 5 Street

7 floors · 15 apartments · 18,000 sq ft · built 2008 · class D3 · owner of record: Dmr Holding Llc C/O N

39open violations
$10,000ECB/OATH penalties owed
11HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 51 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 51 days
Annual
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 67 days
Annual
Facade inspection report (Cycle 10A) Applies
Local Law 11 / FISP · Feb 21, 2025 to Feb 21, 2027
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 4, 5, 6 or 9 are in sub-cycle 10A. Agency page

Feb 21, 2027
in 103 days
No Cycle 10 report on record yet
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueNo current registration found
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 13 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1147 days
Next cycle year 2029

Open violations

ECB / OATH (5) · $10,000 owed
IssuedViolationHearingBalance
Sep 16, 2026Construction CLASS - 1
ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY: AT THE TIME OF INSPECTION, OBSERVED NB ERECTED UNDER JOB #302300212 FOR 7-STORY, 15-FAMILY RESIDENTIAL BUILDING, 2ND - 5TH FL. CONTAIN
#39204284Z
Nov 25, 2026
PENDING
$6,250
Jul 22, 2025Construction CLASS - 1
BUILDING OR OPEN LOT OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY; OBSERVED 7 STORY MULTIPLE DWELLING BUILDING BEING OCCUPIED WITHOUT A VALID C OF O. NO CERTIFICATE OF OCCUPANCY HAS BEEN ISSUED TO NEW BUIL
#39154496H
Nov 12, 2025
IN VIOLATION
$2,500
Mar 19, 2024Construction CLASS - 2
FAILURE TO COMPLY WITH COMMISSIONER'S ORDER CONTAINED IN SUMMONS #39036200M ISSUED ON 2/12/2021, AND FAILURE TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28.201.1 AND 1RCNY 102-01(D)(2). AN ACCEPTABLE CERTIF
#37027137L
Oct 25, 2024
IN VIOLATION
$1,250
Jun 8, 2022Construction CLASS - 1
BUILDING OR OPEN LOT OCCUPIED WITHOUT A VALID CERT. OF OCCUPANCY. OBSERVED 7 STORY MULTIPLE DWELLING OCCUPIED WITHOUT A VALID C OF O - NO CO ISSUED UNDER NB JOB#302300212 & ALL PERMITS EXPIRED. REPEAT VIOLATION
#39063762H
Nov 16, 2022
IN VIOLATION
$0
Jun 8, 2022Construction CLASS - 2
FAILURE TO COMPLY WITH THE DEPT OF BUILDINGS REQUIREMENT FOR PERMIT SIGN-OFF. RESPONDENT OBTAINED PERMIT # 302300212 WHICH EXPIRED 05/09/2017 PERMIT HAS NOT BEEN SIGNED OFF WITHIN 1 YEAR FOLLOWING ITS EXPIRATIO
#39063761X
Nov 16, 2022
IN VIOLATION
$0
DOB (0)

None open.

DOB NOW Safety (3)
IssuedViolationStatus
Oct 21, 2026AEUHAZ FTC-AEU-HAZ
Active
Oct 2, 2026Elevators FTF-VT-CAT1-CO
Violation Issued-Failure To File 2025 Cat1 Test Report
Active
Aug 29, 2025Elevators FTF-VT-PER-CO
Violation Issued-Failure To File 2024 Periodic Inspection Report
Active
HPD (32) · C 11 · B 15 · A 6
IssuedClassViolationCorrect by
May 8, 2026A(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.Aug 11, 2026
Apr 30, 2025CApt 2C · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER EXCEEDS THE MAXIMUM ALLOWABLE OPERATING TEMPERATURE OF 130F AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHMay 6, 2025
Apr 30, 2025BApt 2C · § 27-2005 HMC: REFIT DOOR IN THE ENTRANCE LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHJun 4, 2025
Mar 18, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE HINGES AT BOILER ROOM, AT ROOFApr 1, 2025
Mar 17, 2025BApt 2C · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES AT BATHTUB IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 21, 2025
Mar 17, 2025BApt 2C · § 27-2024 ADM CODE PROVIDE ADEQUATE SUPPLY OF COLD WATER FOR THE FIXTURES AT BATHTUB IN THE BATHROOM LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 21, 2025
Mar 17, 2025BApt 2C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INDIVIDUAL HEATING SYSTEM AT EAST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 21, 2025
Mar 17, 2025CApt 2C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE HEAVY DUTY LOCKSET AT APARTMENT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHMar 23, 2025
Mar 17, 2025BApt 2C · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 21, 2025
Mar 17, 2025C§ 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT HINGES , AT BULKHEAD DOOR AT PUBLIC HALL STAIRS, 7th STORYMar 31, 2025
Mar 17, 2025BApt 2C · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 21, 2025
Mar 17, 2025CApt 2C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE AT HINGES , AT ENTRANCE DOOR IN THE ENTRANCE LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHMar 31, 2025
Mar 17, 2025CApt 2C · § 27-2029 ADM CODE PROVIDE AN ADEQUATE SUPPLY OF HEAT FOR THE APARTMENT IN THE ENTIRE APARTMENT LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHMar 13, 2025
Mar 17, 2025BApt 2C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE GFCI RECEPTACLE AT SOUTH WALL IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 21, 2025
Mar 17, 2025BApt 2C · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE VENTILATION UNIT IN THE KITCHEN LOCATED AT APT 2C, 2nd STORY, 1st APARTMENT FROM EAST AT SOUTHApr 21, 2025
Mar 11, 2025C§ 27-2005, 2007 ADM CODE REMOVE DEVICE PREVENTING DOOR FROM BEING SELF-CLOSING TEMPORARILY INSTALLED WEDGE AT DOOR LEADING TO 1ST STORY PUBLIC HALL STAIRS PREVENTING IT FROM BEING SELF CLOSING AT PUBLIC HALL, 1st STORYMar 25, 2025
Jan 11, 2024A§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORYApr 15, 2024
Jan 11, 2024A§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORYApr 15, 2024
Jan 11, 2024A§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT PUBLIC HALL, 1st STORYApr 15, 2024
Jan 11, 2024A§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORYApr 15, 2024
Jan 11, 2024CApt 3C · § 27-2005, 27-2007, 27-2041.1 HMC, §238, § 309; § 107 (2) ( C) MDL AND 28 RCNY §25-171: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .... IN THE ENTRANCE LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHJan 25, 2024
Jan 10, 2024CApt 3C · § 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 3C, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTHJan 10, 2024
Jun 9, 2022CApt 4C · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4C, 4th STORY, 1st APARTMENT FROM EAST AT SOUTHJul 5, 2022
Jun 9, 2022A§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT PUBLIC HALL, 1st STORYSep 12, 2022
Dec 9, 2014BApt 5C · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 13, 2015
Dec 9, 2014BApt 5C · § 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 5C, 5th STORY, 1st APARTMENT FROM SOUTH AT WESTJan 13, 2015
Jul 7, 2014BApt 6A · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERATIVE LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTAug 11, 2014
Jul 7, 2014CApt 6A · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 7; WG TO REPLACE = 0; WG TO REPAIR = 0; LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM SOUTH AT WESAug 4, 2014
Jul 7, 2014BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CLOSET CEILING AT EAST OFFSET # 1 IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTAug 11, 2014
Jul 7, 2014BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE KITCHENETTE LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTAug 11, 2014
Jul 7, 2014BApt 6A · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE 2nd ROOM FROM NORTH LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTAug 11, 2014
Jul 7, 2014BApt 6A · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERATIVE LOCATED AT APT 6A, 6th STORY, 1st APARTMENT FROM SOUTH AT WESTAug 11, 2014

Issued in the last 120 days

DateSourceWhatNow
Oct 21, 2026DOB SafetyAEUHAZ: Open
Oct 2, 2026DOB SafetyElevators: Violation Issued-Failure To File 2025 Cat1 Test ReportOpen
Sep 16, 2026ECBConstruction: ALTERED/CHANGED BUILDING OCCUPIED WITHOUT A VALID CERTIFICATE OF OCCUPANCY: AT THE TIME OF INSPECTION, OBSERVED NB ERECTED UNDER JOB #302300212 FOR 7-STORY, 15-FAMILY RESIDENTIAL BUILDING, 2ND - 5TH FL. CONTAINOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 10, 2026, 4:28 AM ET. BBL 3086740023.