20 floors · 22,841 sq ft · built 2004 · class RH · owner of record: Yad Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 47 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Facade inspection report (Cycle 10C) Applies Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $90,000 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2029 in 830 days | Filing window not open yet |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Aug 5, 2026 | Elevators CLASS - 2 CLASS 2: IN-CAR POSITION INDICATOR INOPERATIVE. AS PER ASME A17.1 8.6. REMEDY: REPAIR OR REPLACE INDICATOR AND VERIFY PROPER FLOOR DISPLAY. EMERGENCY PHONE INOPERATIVE; RESPONDENT UNABLE TO HEAR OCCUPANT IN THE #39199341M | Mar 30, 2027 PENDING | $625 |
| Aug 5, 2026 | Construction CLASS - 2 AT THE TIME OF INSPECTION OBSERVED SEVERELY RUSTED NUTS AND BOLTS ALSO CORRODED COPPER PIPING WAS SOAKED AND LEAKING WITH WATER ON THE MAIN SPRINKLER RPZ WHICH IS CONTRARY TO FC 901.6 & FC 901.6.1, REPAIR AND/O #39199221H | Mar 30, 2027 PENDING | $1,250 |
| Aug 5, 2026 | Elevators CLASS - 2 CLASS 2: SEPARATING CAR DOORS AT THE BOTTOM IN CLOSED POSITION CREATES EXCESSIVE GAP AND EXPOSES ACCESS TO THE HOISTWAY WHILE THE CAR IS IN MOTION, INDICATING IMPROPER ECCENTRICS ADJUSTMENT. AS PER ASME A17.1 2 #39199342Y | Mar 30, 2027 PENDING | $625 |
| Aug 5, 2026 | Construction CLASS - 1 ATOI OBSERVED THROUGHOUT THE BUILDING OBSTRUCTION OF SPRINKLER HEADS AND PAINTED SPRINKLER HEADS WHICH IS CONTRARY TO 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKLER #39199220X | Mar 30, 2027 | $2,500 |
| Oct 29, 2025 | Construction CLASS - 2 FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39121097J ISSUED ON 08/07/2024 FOR UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE, FILE #39165351K | May 17, 2027 DEFAULT | $6,250 |
| Aug 7, 2024 | Unknown CLASS - 1 I OBSERVED IN THE MAIN ELECTRICAL SERVICE ROOM THE INSTALLATION OF THE EMERGENCY ATS DISCONNECT AS PER EC NO PARTS OF THE ATS SYSTEM SHALL BE INSTALLED WITH THE MAIN ELECTRICAL SERVICE. PHOTOS TAKEN, COMPLY WIT #39121097J | Dec 5, 2024 IN VIOLATION | $0 |
| Aug 7, 2024 | Unknown CLASS - 1 I OBSERVED IN THE BASEMENT WATER METER ROOM THE ELECTRICAL GROUNDING SYSTEM IN A SEVERE STATE OF CORROSION AND ALSO NOTED THE EMERGENCY GENERATOR ALSO. AS PER OF THE SAFETY SYSTEMS FOR THE BUILDING THIS AN IMME #39121096H | Dec 5, 2024 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Oct 30, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00058 | DOB VIOLATION - ACTIVE |
| Oct 16, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00051 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Oct 30, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 16, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
None open.
| Date | Source | What | Now |
|---|---|---|---|
| Aug 5, 2026 | ECB | Elevators: CLASS 2: IN-CAR POSITION INDICATOR INOPERATIVE. AS PER ASME A17.1 8.6. REMEDY: REPAIR OR REPLACE INDICATOR AND VERIFY PROPER FLOOR DISPLAY. EMERGENCY PHONE INOPERATIVE; RESPONDENT UNABLE TO HEAR OCCUPANT IN THE | Open |
| Aug 5, 2026 | ECB | Construction: AT THE TIME OF INSPECTION OBSERVED SEVERELY RUSTED NUTS AND BOLTS ALSO CORRODED COPPER PIPING WAS SOAKED AND LEAKING WITH WATER ON THE MAIN SPRINKLER RPZ WHICH IS CONTRARY TO FC 901.6 & FC 901.6.1, REPAIR AND/O | Open |
| Aug 5, 2026 | ECB | Elevators: CLASS 2: SEPARATING CAR DOORS AT THE BOTTOM IN CLOSED POSITION CREATES EXCESSIVE GAP AND EXPOSES ACCESS TO THE HOISTWAY WHILE THE CAR IS IN MOTION, INDICATING IMPROPER ECCENTRICS ADJUSTMENT. AS PER ASME A17.1 2 | Open |
| Aug 5, 2026 | ECB | Construction: ATOI OBSERVED THROUGHOUT THE BUILDING OBSTRUCTION OF SPRINKLER HEADS AND PAINTED SPRINKLER HEADS WHICH IS CONTRARY TO 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKLER | Closed |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 2:37 PM ET. BBL 1007637503.