Manhattan · Block 763 · Lot 7503 · 10018

305 West 39th Street

20 floors · 22,841 sq ft · built 2004 · class RH · owner of record: Yad Llc

10open violations
$11,250ECB/OATH penalties owed
0HPD class C (immediately hazardous)
47dto Gas piping inspection (2026 cycle)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 4 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 47 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 47 days
Keep the report on file (not filed with DOB)
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $90,000 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 830 days
Filing window not open yet

Open violations

ECB / OATH (7) · $11,250 owed
IssuedViolationHearingBalance
Aug 5, 2026Elevators CLASS - 2
CLASS 2: IN-CAR POSITION INDICATOR INOPERATIVE. AS PER ASME A17.1 8.6. REMEDY: REPAIR OR REPLACE INDICATOR AND VERIFY PROPER FLOOR DISPLAY. EMERGENCY PHONE INOPERATIVE; RESPONDENT UNABLE TO HEAR OCCUPANT IN THE
#39199341M
Mar 30, 2027
PENDING
$625
Aug 5, 2026Construction CLASS - 2
AT THE TIME OF INSPECTION OBSERVED SEVERELY RUSTED NUTS AND BOLTS ALSO CORRODED COPPER PIPING WAS SOAKED AND LEAKING WITH WATER ON THE MAIN SPRINKLER RPZ WHICH IS CONTRARY TO FC 901.6 & FC 901.6.1, REPAIR AND/O
#39199221H
Mar 30, 2027
PENDING
$1,250
Aug 5, 2026Elevators CLASS - 2
CLASS 2: SEPARATING CAR DOORS AT THE BOTTOM IN CLOSED POSITION CREATES EXCESSIVE GAP AND EXPOSES ACCESS TO THE HOISTWAY WHILE THE CAR IS IN MOTION, INDICATING IMPROPER ECCENTRICS ADJUSTMENT. AS PER ASME A17.1 2
#39199342Y
Mar 30, 2027
PENDING
$625
Aug 5, 2026Construction CLASS - 1
ATOI OBSERVED THROUGHOUT THE BUILDING OBSTRUCTION OF SPRINKLER HEADS AND PAINTED SPRINKLER HEADS WHICH IS CONTRARY TO 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKLER
#39199220X
Mar 30, 2027
$2,500
Oct 29, 2025Construction CLASS - 2
FAILURE TO SUBMIT CERTIFICATE OF CORRECTION FOR VIOLATION # 39121097J ISSUED ON 08/07/2024 FOR UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE, FILE
#39165351K
May 17, 2027
DEFAULT
$6,250
Aug 7, 2024Unknown CLASS - 1
I OBSERVED IN THE MAIN ELECTRICAL SERVICE ROOM THE INSTALLATION OF THE EMERGENCY ATS DISCONNECT AS PER EC NO PARTS OF THE ATS SYSTEM SHALL BE INSTALLED WITH THE MAIN ELECTRICAL SERVICE. PHOTOS TAKEN, COMPLY WIT
#39121097J
Dec 5, 2024
IN VIOLATION
$0
Aug 7, 2024Unknown CLASS - 1
I OBSERVED IN THE BASEMENT WATER METER ROOM THE ELECTRICAL GROUNDING SYSTEM IN A SEVERE STATE OF CORROSION AND ALSO NOTED THE EMERGENCY GENERATOR ALSO. AS PER OF THE SAFETY SYSTEMS FOR THE BUILDING THIS AN IMME
#39121096H
Dec 5, 2024
IN VIOLATION
$0
DOB (2)
IssuedViolationStatus
Oct 30, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00058
DOB VIOLATION - ACTIVE
Oct 16, 2024FAIL TO CERTIFY CLASS 1
FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
#00051
DOB VIOLATION - ACTIVE
DOB NOW Safety (2)
IssuedViolationStatus
Oct 30, 2024AEUHAZ FTC-AEU-HAZ
Active
Oct 16, 2024AEUHAZ FTC-AEU-HAZ
Active
HPD (0)

None open.

Issued in the last 120 days

DateSourceWhatNow
Aug 5, 2026ECBElevators: CLASS 2: IN-CAR POSITION INDICATOR INOPERATIVE. AS PER ASME A17.1 8.6. REMEDY: REPAIR OR REPLACE INDICATOR AND VERIFY PROPER FLOOR DISPLAY. EMERGENCY PHONE INOPERATIVE; RESPONDENT UNABLE TO HEAR OCCUPANT IN THEOpen
Aug 5, 2026ECBConstruction: AT THE TIME OF INSPECTION OBSERVED SEVERELY RUSTED NUTS AND BOLTS ALSO CORRODED COPPER PIPING WAS SOAKED AND LEAKING WITH WATER ON THE MAIN SPRINKLER RPZ WHICH IS CONTRARY TO FC 901.6 & FC 901.6.1, REPAIR AND/OOpen
Aug 5, 2026ECBElevators: CLASS 2: SEPARATING CAR DOORS AT THE BOTTOM IN CLOSED POSITION CREATES EXCESSIVE GAP AND EXPOSES ACCESS TO THE HOISTWAY WHILE THE CAR IS IN MOTION, INDICATING IMPROPER ECCENTRICS ADJUSTMENT. AS PER ASME A17.1 2Open
Aug 5, 2026ECBConstruction: ATOI OBSERVED THROUGHOUT THE BUILDING OBSTRUCTION OF SPRINKLER HEADS AND PAINTED SPRINKLER HEADS WHICH IS CONTRARY TO 903.3.3 OBSTRUCTED LOCATIONS IN AUTOMATIC FIRE SPRINKLER SYSTEMS. IT MANDATES THAT SPRINKLERClosed