Brooklyn · Block 1610 · Lot 63 · 11221

305 Van Buren Street

2 floors · 2 apartments · 2,295 sq ft · built 1899 · class B3 · owner of record: Miller, Darrin

16open violations
$25,000ECB/OATH penalties owed
0HPD class C (immediately hazardous)
290dto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 290 days
Required only if the owner doesn't live there

Open violations

ECB / OATH (2) · $25,000 owed
IssuedViolationHearingBalance
Dec 22, 2025Construction CLASS - 1
AT THE TIME OF MY INSPECTION, I OBSERVED FACADE COLLAPSE AT EXPOSURE #2 AND DEMOLITION STARTED AT THE 3RD FLOOR FACADE. INVESTIGATION REVEAL THAT THE COMMISSIONER ORDER WAS TO PROVIDE SHORING FROM THE CELLAR TO
#39548341P
Feb 25, 2026
DEFAULT
$12,500
Nov 28, 2025Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. AS NOTED: AT TIME OF INSPECTION OBSERVED BRICK WALL AT EXP #2 THAT HAS COLLAPSED ONTOTHE ADJ. PROPERTIES ROOF. FAILED TO MAINTAIN BUILDING IN CODE-COMPLIAN
#35685743N
Feb 9, 2027
DEFAULT
$12,500
DOB (6)
IssuedViolationStatus
Dec 9, 2025IMMEDIATE EMERGENCY
IMMEDIATELY INSTALL 2 LINES OF TEMPORARY SHORING ALONG EXPOSURE 2, FROM CELLAR UP UNDERSIDE OF ROOF, EXTENDING THE FULL LENGTH OF THE BUILDING FROM FRONT TO BACK. INSTALL TRANSVERSE CROSS BRACING BETWEEN THE 2 LINES OF SHORING. AFTER SHORING IS INSTALLED, PARTIALLY
#19801
DOB VIOLATION - ACTIVE
Dec 8, 2025CONSTRUCTION
EMERGENCY WORK ORDER.ON/AROUND 11/28/25,EXP2,8INCH BEARNG APPRX 15 LF CLLPSD ONTO ADJ 303 ROOF.REMAINING EXP2 WALL CRCKD&SEVERELY BULGNG OUT &AT RISK OF CLLPSE.EXP2 RUBBLE FDN WALL PRTLLY.OWNR TO IMMED RETAIN NYSPE&GC ENDRSD FOR DEMO TO 1.PE TO PRVDE MEANS&METHDS TO DOB-FEU FOR REVIEW&APPRVL
#FEU30301PN
DOB VIOLATION - ACTIVE
Dec 4, 2025CONSTRUCTION
EMERGENCY WORK ORDER.ON/AROUND 11/28/25 EXP2 WALL@2ND FLOOR PARTIALLY CLLPSD ONTO ADJ 303 VAM BUREN ROOF.035 EXP2 WALL@RISK OF FURTHER CLLPSE.ROOF&BLDG STRCTRLLY CMPRMSD&POSES DNGR TO THE PUBLIC IMMEDIATELY COMPLY WITH COMMISSIONER'S ORDER 350221 (112825FEU30301PN) DATED 11/28/2025
#FEU30301PN
DOB VIOLATION - ACTIVE
Nov 28, 2025CONSTRUCTION
FAILURE TO MAINTAIN BUILDIING IN CODE COMPLIANT MANNER . AT TIME OF IN SPECTION OBSERVED AT EXPOSURE #2 WALL PARTIAL BRICK WALL COLLAPSE WITH REMAINING SECTIONS LLOSE AND READY TO FALL AFFECTING BUILDING STRUCTU RAL STABILITY : REMEDY SUBMIT ENGINEERS REPORT EVALUATING CITED CONDIT ONS WITH PHOTOS,
#CER01CM
DOB VIOLATION - ACTIVE
Nov 28, 2025CONSTRUCTION
EMERGENCY WORK ORDER.ON/AROUND 11/28/25 EXP2 WALL@2ND FLOOR PARTIALLY CLLPSD ONTO AD 303 VAN BUREN ROOF.305 EXP2 WALL@RISK OF FRTHR CLLPSE ROOF&BLDG STRCTRLLY CMPRMSD&POSES DNGR TO THE PUBLIC.IMMEDIATELY COMPLY COMMISSIONER'S ORDER 350221 (112825FEU30301PN) DATED 11/28/2025
#FEU30303PN
DOB VIOLATION - ACTIVE
Nov 28, 2025CONSTRUCTION
FAILURE TO MAINTAIN BLDG IN A SAFE CONDITION.ON/AROUND 11/28/25.APPRX 1FT,&AT RISK OF COLLAPSE.ROOF UNSUPPORTED/INADEQUATELY SUPPORTED EXTENT OF EXP2 WALL INSTABILITY@LOWER FLOORS.OWNR TO RTAIN NYSPE TO EVAL ENT BLDG&FILE RPAIR DWGS.BLDG TO BE PERM RPAIRD UNDR PRMT STRTNG BY 1/19/26&CMPLTD/SGND OFF
#FEU30302PN
DOB VIOLATION - ACTIVE
DOB NOW Safety (0)

None open.

HPD (8) · C 0 · B 7 · A 1
IssuedClassViolationCorrect by
Jun 25, 2008BSECTION 27-2032, 2034 ADNIM. CODE: DISCONTINUE USE OF ILLEGAL SPACE AND/OR HOT WATER HEATER AND PROVIDE FILED FOR & APPROVED HEATER WHICH OBTAINS COMBUSTION AIR DIRECTLY FROM OUTSIDE THE BUILDING OR APPROVED CENTRAL SYSTEM AT- FRONT AND REAR ROOMS- 2ND STY. APT.Jul 30, 2008
Jun 25, 2008ASECTION 27-2014 ADMIN. CODE AND DEPARTMENT RULES AND REGULATIONS: SCRAPE AND REMOVE RUST SCALES AND PAINT WITH TWO COATS OF PAINT THE REAR FIRE ESCAPE -ALL STYS.Sep 28, 2008
Jun 25, 2008BSECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE BROKEN OR DEFECTIVE MARBLE DOOR SADDLE STREET ENTRANCE TO PUBLIC VESTIBULE.Jul 30, 2008
Jun 25, 2008BSECTION 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF REFRIGERATOR 1ST STY PUBLIC HALL.Jul 30, 2008
Jun 25, 2008BSECTION 27-2005, 2007 ADMIN. CODE: REMOVE ALL ENCUMBRANCES CONSISTING OF WARDROBE & SPACE HEATER 2ND STY PUBLIC HALL.Jul 30, 2008
Jun 25, 2008BSECTION 27-2005 ADMIN. CODE: REPLACE WITH NEW THE MISSING GLASS SKYLIGHT ABOVE BATHROOM ROOF REAR.Jul 30, 2008
Jun 25, 2008BSECTION 27-2005 ADMIN. CODE: FIRE ESCAPE DEFECTIVE. FILL IN HOLES IN WALL AROUND BRACKETS AND/OR RAILSJul 30, 2008
Jun 25, 2008BSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR THE BROKEN OR DEFECTIVE BRICKWORK AREA AT 3RD STY SOUTH WINDOW BUILDING FRONT.Jul 30, 2008