Manhattan · Block 851 · Lot 41 · 10010

304 Park Avenue South

12 floors · 183,815 sq ft · built 1930 · class O6 · owner of record: 304 Pas Owner Llc

11open violations
$0ECB/OATH penalties owed
0HPD class C (immediately hazardous)
163dto Energy and water benchmarking

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 42 days
Keep the report on file (not filed with DOB)
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 183,815 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 163 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 163 days
Annual filing
Facade inspection report (Cycle 10C) Applies
Local Law 11 / FISP · Feb 21, 2027 to Feb 21, 2029
What this is

Buildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 1, 2 or 3 are in sub-cycle 10C. DOB facade records for this building show $182,250 in late-filing or failure-to-file penalties. Agency page

Feb 21, 2029
in 825 days
Filing window not open yet
Gas piping inspection (2029 cycle) Likely applies
Local Law 152 · During 2029
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 5 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2029
in 1138 days
Next cycle year 2029
Energy audit and retro-commissioning (2031) Likely applies
Local Law 87 · Calendar year 2031
What this is

Buildings over 50,000 sq ft file an Energy Efficiency Report every ten years, in the year whose last digit matches the last digit of the tax block (block 851). Agency page

Dec 31, 2031
in 1868 days
Next due 2031
Annual boiler inspection (2 boilers) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-24 (Accepted). Agency page

On file2026 reports accepted

Open violations

ECB / OATH (2)
IssuedViolationHearingBalance
Oct 8, 2021Local Law CLASS - 2
FAILURE TO FILE ACCEPTABLE AMENDED CYCLE8C AND9C REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY28-302.5 FOR CONTROL#902365.FILE ACCEPTABLE REPORT
#37022123H
Feb 24, 2022
IN VIOLATION
$0
Apr 27, 2020Construction CLASS - 2
FAILURE TO MAINTAIN/DISPLAY ON SITE DOCUMENTS REQUIRED BY BC CHAPTER33AT TIME OF INSPECTION ON OPEN PERMIT I OBSERVED ACTIVE SITE W/A SUPERINTENDENT PRESENT. UPON REQUEST FOR APPROVED DOCUMENTS PLANS & SAFETY
#35480441Z
Aug 13, 2020
IN VIOLATION
$0
DOB (4)
IssuedViolationStatus
Dec 23, 2022HAZARDOUS CONDITION (FACADE)
CYCLE 9C UNSAFE REPORT FILED
#910614
DOB VIOLATION - ACTIVE
Mar 26, 2020FACADE SAFETY PROGRAM
UNSAFE REPORT FILED
#HAZ88846
DOB VIOLATION - ACTIVE
Mar 26, 2020FACADE SAFETY PROGRAM
UNSAFE REPORT FILED
#HAZ92360
DOB VIOLATION - ACTIVE
Mar 26, 2020FAILURE TO CORRECT SWARMP CONDITIONS (FACADE)
CYCLE 9C FAILURE TO CORRECT SWARMP CONDITIONS
#00015
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Dec 23, 2022Facades FISPHAZ
CYCLE 9C UNSAFE REPORT FILED
Active
Mar 26, 2020Facades FISP
UNSAFE REPORT FILED
Active
Mar 26, 2020Facades FISPFCS
CYCLE 9C FAILURE TO CORRECT SWARMP CONDITIONS
Active
Mar 26, 2020Facades FISP
UNSAFE REPORT FILED
Active
Apr 30, 2019Facades FISPNRF
FAILED TO FILE FISP CYCLE 8C TECHNICAL REPORT BY 02/21/2019
Active
HPD (0)

None open.

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Nov 19, 2026, 7:33 AM ET. BBL 1008510041.