| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 69 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 69 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 69 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 85 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 39,894 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 190 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 190 days | Annual filing |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-10 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Sep 8, 2026 | Elevators CLASS - 1 FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLAINT AS PER BC3001.2 & 27-987. CEASE USE CLASS 1: DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/DISABLED AND RENDERED INOPERATIVE, THIS IS A DEVICE TO ENSURE HUM #39203278H | Nov 20, 2026 PENDING | $1,250 |
| Mar 10, 2026 | Elevators CLASS - 2 CLASS 2 ITEMS: PROVIDE ACCESS TO ELEVATOR MACHINE ROOM & PIT. ADJUST FLOOR STOPS AS NEEDED. IN CAR COMMUNICATION INOPERATIVE. #39179891Z | Oct 2, 2026 DEFAULT | $655 |
| Apr 6, 2023 | Construction CLASS - 2 AT TIME OF MY INSPECTION OF A 6 STORY BUILDING WITH A SIDEWALK SHED. I NOTICED THAT SIDEWALK SHED IS NOT FULLY EXTENDED THE FULL WIDTH OF SIDEWALK AND ITS NOT EXTENDED AT EXPOSURE#4 5FT TO PROTECT NEIGHBORING B #39515068M | Jun 16, 2023 DEFAULT | $0 |
| Apr 3, 1991 | Cranes and Derricks Non-Hazardous 1) USE OF RIGGING EQUIPMENT WITHOUT SPECIAL RIGGERS LICENSE (OBTAIN LICENSE). 2) USE OF RIGGING EQUIPMENT WITHOUT PROPER DANGER SIGNS (PROVIDE DANGER SIGNS). STOP WORK ORDER ISSUED # 3571. #34047909L | Jun 6, 1991 WRITTEN OFF | $0 |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2024 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 #00557 | DOB VIOLATION - ACTIVE |
| Dec 31, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013 #01008 | DOB VIOLATION - ACTIVE |
| Aug 8, 2002 | LOCAL LAW 11/98 - FACADE #NRF52338 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Feb 22, 2024 | Facades FISPNRF FAILED TO FILE FISP CYCLE 9C TECHNICAL REPORT BY 2/21/2024 | Active |
| Aug 11, 2023 | Elevators FTF-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Report | Active |
| Dec 31, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7C TECHNICAL REPORT BY 02/21/2013 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Jun 10, 2024 | B | Apt 43 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK ABOVE THE CEILING IN THE BATHROOM LOCATED AT APT 43, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST | Jul 15, 2024 |
| Jun 10, 2024 | B | Apt 43 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING AND NORTH WALL IN THE BATHROOM LOCATED AT APT 43, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST | Jul 15, 2024 |
| Jun 6, 2024 | C | Apt 43 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 43, 4th STORY, 2nd APARTMENT FROM NORTH AT EAST | Jul 2, 2024 |
| Sep 12, 2023 | C | Apt 32 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... APPROX 30 SQ.FT AT NORTH AND WEST WALLS IN THE BATHROOM LOCATED AT APT 32, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 8, 2023 |
| Feb 1, 2023 | C | Apt 7 · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | Feb 25, 2023 |
| Sep 20, 2021 | B | Apt 7 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 25, 2021 |
| Sep 20, 2021 | B | Apt 7 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE 3rd ROOM FROM NORTH LOCATED AT APT 7, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Oct 25, 2021 |
| Sep 20, 2021 | C | § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND ASSEMBLY AT BUILDING ENTRANCE DOOR , 1st STORY | Sep 26, 2021 |
| Aug 2, 2021 | C | Apt 7 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 7, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Aug 28, 2021 |
| May 25, 2021 | C | Apt 7 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 7, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jun 20, 2021 |
| Dec 10, 2020 | B | Apt 7 · § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING WATER CLOSET TANK COVER IN THE BATHROOM LOCATED AT APT 7, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST | Jan 14, 2021 |
| Jan 21, 2020 | C | Apt 7 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 7, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH | Feb 11, 2020 |
| Jan 21, 2020 | C | Apt 7 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 7, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST , SECTION AT NORTH | Feb 11, 2020 |
| Oct 15, 2019 | C | Apt 52 · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT CEILING AND NORTH WALL ( APPROX 20 SQ.FT ) IN THE BATHROOM LOCATED AT APT 52, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH ORIGINAL VIOLATION 13201644 ISSUED 30-JUL-19 HAS BEEN UPGRADED TO CLASS C PER ADMINISTRATI | Nov 5, 2019 |
| Aug 1, 2019 | C | Apt 52 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE LOCATED AT APT 52, 5th STORY, 1st APARTMENT FROM EAST AT SOUTH | Aug 22, 2019 |
| Date | Source | What | Now |
|---|---|---|---|
| Sep 8, 2026 | ECB | Elevators: FAILURE TO MAINTAIN ELEVATOR IN BUILDING CODE COMPLAINT AS PER BC3001.2 & 27-987. CEASE USE CLASS 1: DOOR ZONE RESTRICTOR HAS BEEN TAMPERED WITH/DISABLED AND RENDERED INOPERATIVE, THIS IS A DEVICE TO ENSURE HUM | Open |