Bronx · Block 5703 · Lot 203 · 10463

3033 Godwin Terrace

5 floors · 43 apartments · 43,990 sq ft · built 1926 · class C1 · owner of record: Godwin Company Llc

18open violations
$2,500ECB/OATH penalties owed
6HPD class C (immediately hazardous)
Overdueto Annual property registration

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual property registration Applies
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

OverdueRegistration expired 2026-09-01
Gas piping inspection (2026 cycle) Likely applies
Local Law 152 · During 2026
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2026
in 66 days
Due this year
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 66 days
Keep the report on file (not filed with DOB)
Bedbug annual filing Applies
Local Law 69 · December 1 to 31 each year
What this is

Owners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page

Dec 31, 2026
in 66 days
Annual
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-05-06 (Accepted). Agency page

Dec 31, 2026
in 66 days
1 of 1 without an accepted 2026 report yet
Annual notice: window guards and lead paint Applies
HPD / Health Code · January 1 to 16 each year
What this is

Deliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page

Jan 16, 2027
in 82 days
Annual
Energy and water benchmarking Likely applies
Local Law 84 · May 1 each year
What this is

Buildings over 25,000 sq ft (this lot shows 43,990 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page

May 1, 2027
in 187 days
Annual filing
Building emissions report Likely applies
Local Law 97 · May 1 each year (extensions available)
What this is

Covered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page

May 1, 2027
in 187 days
Annual filing

Open violations

ECB / OATH (1) · $2,500 owed
IssuedViolationHearingBalance
Jun 8, 2026Construction CLASS - 1
FAILURE TO MAINTAIN EXTERIOR BUILDING PARAPET WALL AT EXPOSURE 1. AT TIME OF INSPECTION, OBSERVED THE PARAPET WALL DEFLECTING INWARD TOWARD THE ROOF, INDICATING THE WALL IS OUT OF PLUMB. FURTHER OBSERVED DISPLA
#39191646R
Mar 12, 2027
PENDING
$2,500
DOB (1)
IssuedViolationStatus
Jun 8, 2026CONSTRUCTION
REQUESTING A STRUCTURAL STABILITY REPORT DUE TO THE PARAPET WALL AT EXPOSURE 1 OBSERVED DEFLECTING INWARD TOWARD THE ROOF AND OUT OF PLUMB, WITH DISPLACED AND DETERIORATED COPING STONES, OPEN JOINTS, AND APPARENT MOVEMENT AT THE CORNER OF THE PARAPET ASSEMBLY. THE CONDITION INDICATES POTENTIAL STRUC
#26-01494
DOB VIOLATION - ACTIVE
DOB NOW Safety (5)
IssuedViolationStatus
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2022 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2020 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2021 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2018 External Inspection Affirmation of Correction for LP Device
Active
Nov 14, 2023Boiler FTC-BE-EXT-LP
Violation Issued-Failure To File 2019 External Inspection Affirmation of Correction for LP Device
Active
HPD (11) · C 6 · B 4 · A 1
IssuedClassViolationCorrect by
Oct 22, 2026AApt 3E · § 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OBSERVED LESS THAN 10 SQ FT AT THE CEILING IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTJan 25, 2027
Oct 22, 2026BApt 3E · § 27-2005 HMC: REFIT LOWER SASH AT 1ST WINDOW FROM EAST AT SOUTH IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 26, 2026
Oct 22, 2026BApt 3E · § 27-2005 HMC: REFIT LOWER SASH AT 1ST AND 2ND WINDOW FROM EAST AT SOUTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 26, 2026
Oct 22, 2026CApt 3E · § 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WINDOW SASH HANDLE CRETING CUT HAZARD AT 1ST AND 2ND WI DOW FROM EAST SOUTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOct 28, 2026
Oct 22, 2026BApt 3E · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE WEST WALL IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 26, 2026
Oct 22, 2026BApt 3E · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE WEST WALL IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTNov 26, 2026
Jun 8, 2026C§ 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT CURVING/DAMAGE (BRICK AND MORTAR) AT SOUTH EXTERIOR WALL (EAST SECTION) (PARAPIT WALL)Jun 14, 2026
Jun 8, 2026C§ 27-2005 ADM CODE MAKE SAFE BY PROPERLY REPAIRING THE STRUCTURAL DEFECT HORIZONTAL CRACKING (BRICK AND MOTAR) AT EAST EXTERIOR WALL (SOUTH COURT YARD) (BUILDING FRONT) (RR)Jun 14, 2026
Nov 5, 2025C§ 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT BOILER ROOMNov 11, 2025
Nov 5, 2025CApt 2F · § 27-2043.1 HMC INSTALL THE MISSING OR REPAIR/REPLACE THE DEFECTIVE WINDOW GUARD(S) IN ACCORDANCE WITH THE SPECIFICATIONS OF THE NEW YORK CITY HEALTH CODE SECTION 24 RCNY CHAPTER 12. WG TO INSTALL = 1, WG TO REPLACE = 0, WG TO REPAIR = 0 IN THE ENTIRE APARTMENT LOCATED AT APT 2F, 2nd STORY, 2nd APARNov 11, 2025
Feb 28, 2012CApt 1H · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM NORTH AT EAST WALL IN THE FOYER LOCATED AT APT 1H, 1st STORY, 1st APARTMMar 25, 2012

Issued in the last 120 days

DateSourceWhatNow
Oct 22, 2026HPD A§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... OBSERVED LESS THAN 10 SQ FT AT THE CEILING IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 22, 2026HPD B§ 27-2005 HMC: REFIT LOWER SASH AT 1ST WINDOW FROM EAST AT SOUTH IN THE KITCHEN LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 22, 2026HPD B§ 27-2005 HMC: REFIT LOWER SASH AT 1ST AND 2ND WINDOW FROM EAST AT SOUTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 22, 2026HPD C§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LOWER WINDOW SASH HANDLE CRETING CUT HAZARD AT 1ST AND 2ND WI DOW FROM EAST SOUTH IN THE 2nd ROOM FROM EAST LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 22, 2026HPD B§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT THE WEST WALL IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen
Oct 22, 2026HPD B§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT THE WEST WALL IN THE BATHROOM LOCATED AT APT 3E, 3rd STORY, 1st APARTMENT FROM SOUTH AT WESTOpen

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 26, 2026, 4:39 AM ET. BBL 2057030203.