3 floors · 40,400 sq ft · built 1925 · class W1 · owner of record: St Johns Rc Church
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 8 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 67 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 67 days | Keep the report on file (not filed with DOB) |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 40,400 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 188 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 188 days | Annual filing |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-06-23 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Mar 24, 2026 | Construction CLASS - 2 REISSUE ON ECB #35717156M. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: FIRE RATED CLASSROOM AND SMOKE DOORS NOT SELF-CLOSING DUE TO BINGING MISSING OR FAULTY HARDWARE ON CLASSROOMS, 311, 310, #35727272Z | Apr 10, 2026 POP/IN-VIO | $0 |
| Mar 24, 2026 | Construction CLASS - 2 28-301.1. REISSUE ON ECB #35717154Z. UNLAWFUL PLACEMENT OF FURNISHINGS, DECORATIONS OR OTHER OBJECTS AT EXITS THAT OBSTRUCT ACCESS TO EGRESSFROM OR VISIBILITY THERE OF PER FDNY 2008 CODE; FC 1027.4. NOTED: THER #35727273K | Apr 10, 2026 POP/IN-VIO | $0 |
| Mar 24, 2026 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NO FIRE STOPPING PER BC 712.3; 27-345. NOTED: FIRE STOPPING MISSING IN SEVERAL LOCATIONS THROUGHOUT ELECTRIC, SWITCH GEAR ROOM, BOILER ROOM, GAS METER ROOM #35727274M | Apr 10, 2026 POP/IN-VIO | $0 |
| Mar 24, 2026 | Construction CLASS - 2 EXIT DOOR NOT SELF-CLOSING. NOTED: EMERGENCY EXTERIOR EXIT DOOR NOT SELF-CLOSING DUE TO BINDING, HARDWARE OR FAULTY HARDWARE ON EXTERIOR HARDWARE ON EXTERIOR DOOR 1ST FLOOR 3C AND EXTERIOR K/D 1ST FLOOR STAIR B #35727275Y | Apr 10, 2026 POP/IN-VIO | $0 |
| Apr 8, 2025 | Construction CLASS - 2 REISSUE#35678775M FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED FIREPROOF SELF CLOSING DOORS AT 3 FL,310,309,307,300,200,206,110,105B,103 NOT CLOSING PROPERLY.REM:COMPLY WITH CODE. #35717156M | Aug 15, 2025 POP/IN-VIO | $0 |
| Apr 8, 2025 | Construction CLASS - 2 28-301.1 REISSUE#35678974P UNLAWFUL PLACEMENT OF FURNISHINGS,DECORATIONS OR OTHER OBJECTS AT EXITS THAT OBSTRUCT ACCESS TO EGRESS FROM OR VISIBILITY.THERE IS FURNITURE ON 2 FLOORS AT THE END OF THE HALLWAYS.BOO #35717154Z | Aug 15, 2025 POP/IN-VIO | $0 |
| Apr 9, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: OBSERVEDINTERIOR FIRE-PROOF SELF CLOSING DOORS LOCATED AT 3 FLR.-310, 309, 307, 300. AT 2 FLR.-200, 206. AT 1 FLR.-110, 105B, 103 ARE NOT CLOSING PR #35678775M | May 17, 2024 POP/IN-VIO | $0 |
| Apr 9, 2024 | Construction CLASS - 2 28-301.1. UNLAWFUL PLACEMENT OF FURNISHINGS, DECORATIONS OR OTHER OBJECTS AT EXITS THAT OBSTRUCT ACCESS TO EGRESS FROM OR VISIBILITY THEREOFPER FDNY 2008 CODE; FC 1027.4. NOTED: OBSERVED THROUGHOUT THE OCCUPIED #35678974P | May 17, 2024 POP/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Aug 29, 1995 | LOCAL LAW 62/91 - BOILERS #17487 | DOB VIOLATION - ACTIVE |
| Jun 9, 1994 | LOCAL LAW 62/91 - BOILERS #02822 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Aug 29, 1995 | Boiler LL6291 | Active |
| Jun 9, 1994 | Boiler LL6291 | Active |
None open.