6 floors · 48 apartments · 42,984 sq ft · built 1923 · class D1 · owner of record: 302 Eastern Corp
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Overdue | Registration expired 2026-09-01 |
| Gas piping inspection (2026 cycle) Likely applies Local Law 152 · During 2026 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 9 is on the 2026 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2026 in 70 days | Due this year |
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 70 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 70 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 86 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 42,984 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 191 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 191 days | Annual filing |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-04-30 (Accepted). Agency page | On file | 2026 reports accepted |
None open.
| Issued | Violation | Status |
|---|---|---|
| Feb 4, 2021 | ELEVATOR #9028/696232 | DOB VIOLATION - ACTIVE |
| Feb 18, 2020 | ELEVATOR #9028/671877 | DOB VIOLATION - ACTIVE |
None open.
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Feb 17, 2021 | C | Apt 2B · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE COUNTER BALANCE AT LOWER SASH WINDOW. GUILLOTINE EFFECT. IN THE 3rd ROOM FROM NORTH AT EAST LOCATED AT APT 2B, 2nd STORY, 4th APARTMENT FROM WEST AT NORTH | Feb 23, 2021 |
| Feb 17, 2021 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES CONSISTING OF FLOWER POTS AT 2ND STORY BALCONY, EAST STACK AT BUILDING FRONT | Mar 24, 2021 |
| Feb 17, 2021 | B | Apt 6F · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE LOCATED AT APT 6F, 5th STORY, 4th APARTMENT FROM EAST AT SOUTH | Mar 24, 2021 |
| Feb 17, 2021 | C | Apt 2B · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE THERMAL WINDOW LOWER SASH COUNTER BALANCES, FIRST WINDOW FROM EAST AT SOUTH WALL, IN THE 3rd ROOM FROM EAST LOCATED AT APT 2B, 2nd STORY, 2nd APARTMENT FROM WEST AT NORTH | Feb 23, 2021 |
| Feb 17, 2021 | C | § 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING CONSISTING OF AN UNACCEPTABLE ELECTROMAGNETIC LOCKING DEVICE INSTALLED AT THE BUILDING ENTRANCE DOOR , 1st STORY | Feb 23, 2021 |
| Feb 17, 2021 | B | Apt 5G · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE PORCELAIN IN BATH TUB IN THE BATHROOM LOCATED AT APT 5G, 5th STORY, 1st APARTMENT FROM WEST AT NORTH | Mar 24, 2021 |
| Feb 17, 2021 | B | Apt 2D · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WEST WOODEN DOOR JAMB IN THE ENTRANCE LOCATED AT APT 2D, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Mar 24, 2021 |
| Jun 10, 2010 | B | Apt 4B · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AND MILDEW AT CEILING 10 SQUARE FEET IN THE BATHROOM FROM NORTH AT WEST LOCATED AT APT 4B, 4th STORY, APARTMENT AT NORTH | Jul 15, 2010 |
| May 6, 2010 | B | Apt 4B · § 27-2005 HMC:TRACE AND REPAIR THE SOURCE AND ABATE THE NUISANCE CONSISTING OF MOLD ... AT CEILING 6 SQ FEET IN THE 2nd BATHROOM FROM NORTH LOCATED AT APT 4B, 4th STORY, 4th APARTMENT FROM WEST AT NORTH | Jun 10, 2010 |
| Apr 28, 1992 | C | Apt 4B · SECTION 27-2013 ADM CODE REMOVE OR COVER IN A MANNER APPROVED BY THE DEPARTMENT THE PEELING LEAD PAINT WALLS & CEILING WATERCLOSET COMPARTMENT & 2ND ROOM FROM NORTH AT EAST 4 STY NORTHEAST APT 4B ER1 0722452. , SECTION '' '' | May 18, 1992 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)