4 floors · 13 apartments · 8,528 sq ft · built 1926 · class C1 · owner of record: Family Trust Uto Floarea Samoila Living Trust
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 47 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 47 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 63 days | Annual |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 291 days | Registered through 2027-09-01 |
| Gas piping inspection (2027 cycle) Likely applies Local Law 152 · During 2027 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 12 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2027 in 412 days | Next cycle year 2027 |
| Annual boiler inspection (1 boiler) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-10-21 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Nov 25, 2025 | Construction CLASS - 2 WORK WITHOUT A PERMIT. I OBSERVED EVIDENCE OF A 3PIECE BATHROOM ARRANGED WITH WATER AND WASTE PIPES, TOILET FLOOR FLANGE AND A SHOWER BODY DIVERTER INSTALLED IN THE FRONT CELLAR. NO PERMIT ON FILE, OBTAIN ALL P #39168270M | Apr 13, 2027 DEFAULT | $3,125 |
| Sep 5, 2025 | Construction CLASS - 2 OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O AND/OR DEPARTMENT OF BUILDING RECORDS.ILLEGALLY CREATED CLASS A APARTMENT AT CELLAR WITH FULL BATHROOM AND KITCHEN CONSISTED OF:GAS STOVE VACATE NOT WARRANTED DUE TO 2N #35482643X | Jun 30, 2026 ADMIT/IN-VIO | $0 |
| Sep 5, 2025 | Construction CLASS - 1 OCCUPANCY CONTRARY TO THAT ALLOWED BY C/O AND/OR DEPARTMENT OF BUILDING RECORDS.ILLEGALLY CREATED B ROOM AT CELLAR WITH FULL BATHROOM AND A KITCHEN CONSISTED OF:NONE APPLIANCES.VACATE IS WARRANTED DUE TO NO 2ND #35482642Y | Jun 30, 2026 ADMIT/IN-VIO | $0 |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | LOW PRESSURE BOILER VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION #07182 | DOB VIOLATION - ACTIVE |
| May 17, 1993 | LOCAL LAW 62/91 - BOILERS #05269 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Nov 14, 2025 | Boiler LBLVIO VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION | Active |
| Jan 31, 2025 | Gas Piping - LL152 FTF-PL-PER Cycle 1, Sub-cycle D (premises is in Community District 12) | Active |
| May 17, 1993 | Boiler LL6291 | Active |
| Issued | Class | Violation | Correct by |
|---|---|---|---|
| Sep 16, 2025 | I | § 27-2142 ADM CODE APTS HAVE BEEN VACATED BY THIS DEPARTMENT AND CANNOT BE REOCCUPIED UNTIL SO ORDERED AFTER PROOF OF COMPLIANCE FOR APTS VACATE 259869 POSTED AT CELLAR APT WEST 1 IN THE ENTIRE APARTMENT LOCATED AT CELLAR APT, 1st CELLAR APT FROM SOUTH AT WEST | — |
| Oct 20, 2025 | B | § 27-2037 ADM CODE PROVIDE ADEQUATE LIGHTING AT SOUTH AT FIRE PASSAGE WAY | Nov 24, 2025 |
| Oct 20, 2025 | B | § 27-2005 ADM CODE PROVIDE SECURITY IN THE EVENT OF A POWER OUTAGE BY MEANS OF AN ACCEPTABLE MECHANICAL HEAVY DUTY LOCK AND LATCH SET AT BUILDING ENTRANCE DOOR AT PUBLIC HALL, 1st STORY | Nov 24, 2025 |
| Sep 10, 2025 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WALLS ERECTED FLOOR TO CEILING CREATING ILLEGAL CLASS ''A'' APARTMENT. 1ST APT FROM NORTH AT EAST AT CELLAR | Dec 14, 2025 |
| Sep 10, 2025 | A | § 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION WALL S ERECTED FLOOR TO CEILING CREATED ILLEGAL ''B'' ROOM 1ST ROOM FROM SOUTH AT WEST AT CELLAR | Dec 14, 2025 |
| May 18, 2022 | C | Apt 7 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF KEY OPERATED LOCK AT THE DOOR LEADING TO THE FIRE ESCAPE WINDOW LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | May 24, 2022 |
| May 18, 2022 | C | Apt 7 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF WOOD BUREAU BLOCKING THE FIRE ESCAPE WINDOW LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | May 24, 2022 |
| Aug 9, 2021 | C | Apt 7 · § 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH A | Sep 2, 2021 |
| Aug 6, 2021 | C | Apt 7 · § 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM NORTH AT EAST WALL IN THE BATHROOM LOCATED AT APT 7, 3rd STORY, 2nd APAR | Sep 13, 2021 |
| Aug 6, 2021 | B | Apt 7 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE CERAMIC FLOOR TILE IN THE BATHROOM LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM SOUTH AT WEST | Sep 10, 2021 |
| Dec 21, 2020 | C | Apt 1 · § 27-2037, 2038 HMC: PROVIDE A SAFE AND ADEQUATE SUPPLY OF ELECTRIC SERVICE TO THE FIXTURES ... IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH | Dec 27, 2020 |
| Oct 15, 2020 | B | Apt 6 · § 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). INOPERABLE LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 19, 2020 |
| Oct 15, 2020 | B | Apt 6 · § 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR INOPERABLE LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 19, 2020 |
| Oct 15, 2020 | B | Apt 6 · § 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT EAST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 19, 2020 |
| Oct 15, 2020 | C | Apt 6 · HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 10, 2020 |
| Oct 15, 2020 | B | Apt 6 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT EAST WALL IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Nov 19, 2020 |
| Oct 15, 2020 | A | Apt 6 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT ALL PEELING PAINT SURFACES IN THE 1st ROOM FROM EAST AT SOUTH LOCATED AT APT 6, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST | Jan 18, 2021 |
| Oct 9, 2020 | B | Apt 8 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXTENSION CORDS ACROSS FLOOR IN THE 3rd ROOM FROM EAST AT SOUTH LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 13, 2020 |
| Oct 9, 2020 | B | Apt 8 · § 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF EXTENSION CORDS ACROSS FLOOR IN THE PRIVATE HALLWAY LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 13, 2020 |
| Oct 7, 2020 | B | Apt 8 · § 27-2005, 2006, 2037 HMC: PROPERLY REPAIR AND ABATE UNSAFE ELECTRIC WIRING CONDITION CONSISTING OF EXPOSED ELECTRICAL WIRES AT SOUTH WALL IN THE 3rd ROOM FROM EAST AT NORTH LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 11, 2020 |
| Oct 7, 2020 | B | Apt 8 · § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE RUBBER GASKET ON REFRIGERATOR DOOR IN THE KITCHEN LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 11, 2020 |
| Oct 7, 2020 | B | Apt 8 · § 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR THE CEILING IN THE BATHROOM LOCATED AT APT 8, 3rd STORY, 1st APARTMENT FROM SOUTH AT WEST | Nov 11, 2020 |
| Jan 28, 2019 | A | § 53, 187, 231 M/D LAW AND DEPARTMENT RULES AND REGULATIONS. PROVIDE A SHOE PROPERLY SECURED TO BOTTOM OF STRING OF DROPLADDER AT BUILDING FRONT AT FIRE ESCAPE | May 3, 2019 |
| Jan 28, 2019 | C | Apt 9 · § 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 9, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Feb 18, 2019 |
| Jan 28, 2019 | C | § 27-2005 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE GLASS PANE UPPER WINDOW SASH AT INTERMIDIATE LANDING AT NORTH WALL AT PUBLIC HALL STAIRS, 1st STORY | Feb 5, 2019 |
| Sep 11, 2018 | B | Apt 9 · § 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE SLOPING WOOD FLOORS IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 9, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 16, 2018 |
| Sep 11, 2018 | B | Apt 9 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW BALANCE AT UPPER SASH IN THE 2nd ROOM FROM EAST AT NORTH LOCATED AT APT 9, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 16, 2018 |
| Sep 11, 2018 | B | Apt 9 · § 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE WINDOW BALANCE AT UPPER AND LOWER SASH IN THE 1st ROOM FROM EAST AT NORTH LOCATED AT APT 9, 3rd STORY, 1st APARTMENT FROM NORTH AT EAST | Oct 16, 2018 |
| May 22, 2018 | B | Apt BSMT · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .... IN THE ENTRANCE LOCATED AT APT BSMT, 1st APARTMENT FROM NORTH AT EAST | Jun 26, 2018 |
| May 1, 2017 | A | § 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT LOBBY, 1st STORY | Aug 4, 2017 |
| May 1, 2017 | A | § 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT LOBBY, 1st STORY | Aug 4, 2017 |
| May 1, 2017 | C | § 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT LOBBY, 1st STORY | May 9, 2017 |
| May 1, 2017 | A | § 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT LOBBY, 1st STORY | Aug 4, 2017 |
| May 1, 2017 | A | § 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX MISSING AT LOBBY, 1st STORY | Aug 4, 2017 |
| May 1, 2017 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR MISSING AT LOBBY, 1st STORY | Aug 4, 2017 |
| May 1, 2017 | A | Apt 7 · § 27-2013 ADM CODE PAINT WITH LIGHT COLORED PAINT TO THE SATISFACTION OF THIS DEPARTMENT AT CEILING IN THE BATHROOM LOCATED AT APT 7, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH | Aug 4, 2017 |
| May 1, 2017 | A | § 27-2053 ADM CODE POST SIGN ON WALL OF ENTRANCE STORY BEARING NAME, ADDRESS INCLUDING APARTMENT NUMBER IF ANY, AND TELEPHONE NUMBER OF SUPERINTENDENT, JANITOR OR HOUSEKEEPER. AT LOBBY, 1st STORY | Aug 4, 2017 |
| Jun 29, 2016 | B | § 27-2005, 2007 ADM CODE AND DEPT. RULES AND REGULATIONS. REMOVE THE ENCUMBRANCE OBSTRUCTING EGRESS FROM FIRE ESCAPES ELECTRIC WIRES AT 3RD STORY BALCONY AT FRONT OF BUILDING AT WEST AT FIRE ESCAPE | Aug 3, 2016 |
| Jun 11, 2007 | B | § 27-2005 ADM CODE REPLACE WITH NEW THE MISSING LIGHT FIXTURE ABOVE MAILBOXES AT WEST WALL AT PUBLIC HALL, 1st STORY | Jul 21, 2007 |
| Jun 11, 2007 | A | § 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR .... AT PUBLIC HALL, 1st STORY | Sep 19, 2007 |
| Jan 2, 2002 | B | Apt 12 · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN MICE. IN THE ENTIRE APARTMENT LOCATED AT APT 12, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST | Feb 11, 2002 |
| Jan 2, 2002 | B | Apt 12 · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES. IN THE ENTIRE APARTMENT LOCATED AT APT 12, 3rd STORY, 2nd APARTMENT FROM NORTH AT EAST | Feb 11, 2002 |
| Dec 18, 1990 | B | Apt 1 · § 27-2018 ADM CODE ABATE THE NUISANCE CONSISTING OF VERMIN ROACHES 1ST STY FRONT SOUTH APT 1 KITCHEN. , SECTION '' '' | Feb 4, 1991 |
| Oct 2, 1990 | B | Apt 7 · § 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE ENTRANCE TO 3RD STY NORTHWEST APT 7. , SECTION '' '' | Nov 19, 1990 |
Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)
City records as of Nov 14, 2026, 7:54 PM ET. BBL 2045700010.