Brooklyn · Block 4930 · Lot 1 · 11226

3010 Beverley Road

3 floors · 2 apartments · 3,800 sq ft · built 1931 · class S9 · owner of record: Ahmad Saleh Ahmad

19open violations
$0ECB/OATH penalties owed
1HPD class C (immediately hazardous)
69dto Annual boiler inspection (1 boiler)

Get an email when anything changes here

New violations the morning after they're issued, plus deadline reminders. Free for one building.

Compliance deadlines

RequirementDueStatus
Annual parapet observation Check
Local Law 126 · By December 31 each year
What this is

If the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page

Dec 31, 2026
in 69 days
Keep the report on file (not filed with DOB)
Annual boiler inspection (1 boiler) Applies
Boiler inspection · By December 31 each year
What this is

Boilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2025-05-06 (Accepted). Agency page

Dec 31, 2026
in 69 days
1 of 1 without an accepted 2026 report yet
Annual property registration Check
HPD registration · September 1 each year
What this is

Residential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page

Sep 1, 2027
in 313 days
Required only if the owner doesn't live there
Gas piping inspection (2027 cycle) Likely applies
Local Law 152 · During 2027
What this is

Buildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 17 is on the 2027 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page

Dec 31, 2027
in 434 days
Next cycle year 2027

Open violations

ECB / OATH (4)
IssuedViolationHearingBalance
Jan 31, 2023Construction CLASS - 1
UNLAWFUL ACTS. FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONER TO COMPLY WITH DOB VIOLATION# VIO-00240 ISSUED 01.26.2023, COMPLY WITH COMMISSIONER'S ORDER
#39078745H
Nov 6, 2023
DEFAULT
$0
Jan 26, 2023Construction CLASS - 1
FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION IN CELLAR I OBSERVED 3 FUTURE TEE CONNECTIONS ON GAS LINE, AND DISCONNECTED FLUE PIPE FROM GAS DRYER., REPAIR AND/REPLACE
#39078462H
Dec 12, 2023
IN VIOLATION
$0
Oct 28, 2010Construction CLASS - 2
FAILURE TO PROVIDE APPROVED PLANS @ THE TIME OF INSPECTION.RE FULL FLR.ENTIRE LENGTH OF STONE.CUTTING BRICK POCKETS TO RECIEVE STEEL BEAMS.NO PLANS AVAILABLE.STOP ALL WORK.REM:PROVIDE APPROVED WORK PLANS @ JOB
#34883785M
Dec 20, 2010
IN VIOLATION
$0
Oct 28, 2010Construction CLASS - 1
WORK W/O A WORK PERMIT.@ TIME OF INSPECTION 3 MEN REMOVING WOOD FLR JOISTS ENTIRE FL REMOVED ON STREET LEVEL @ CORNER STORE.INSTALLING STEELFOR CORRUGATED DECKING.WORK BEHIND THE STEEL ROLL-DOWN GATE.STOP ALL W
#34883784K
Dec 20, 2010
IN VIOLATION
$0
DOB (7)
IssuedViolationStatus
Jun 20, 2023LOW PRESSURE BOILER
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
#07305
DOB VIOLATION - ACTIVE
Jan 26, 2023PLUMBING
OBSERVED DISCONNECTED FLUE PIPE FROM GAS DRYER, WHICH DOES NOT COMPLY WITH SECTION 28-301.1 OF THE ADMIN. CODE, AND PRESENTS AN IMMINENT RISK TO PUBLIC SAFETY. YOU ARE HEREBY ORDERED TO IMMEDIATELY CORRECT THE ABOVE CONDITION BY RETAINING A LIC. PROFESSIONAL TO PERFORM ALL NECESSARY WORK.
#23-00240
DOB VIOLATION - ACTIVE
Nov 8, 2019LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
#06618
DOB VIOLATION - ACTIVE
Apr 6, 2018LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
#08437
DOB VIOLATION - ACTIVE
Oct 1, 2015LOW PRESSURE BOILER
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
#06145
DOB VIOLATION - ACTIVE
Dec 31, 2009LOW PRESSURE BOILER

#15359
DOB VIOLATION - ACTIVE
Jan 1, 2009LOCAL LAW 62/91 - BOILERS

#11253
DOB VIOLATION - ACTIVE
DOB NOW Safety (7)
IssuedViolationStatus
Jan 31, 2025Gas Piping - LL152 FTF-PL-PER
Cycle 1, Sub-cycle D (premises is in Community District 17)
Active
Jun 20, 2023Boiler LBLVIO
VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
Active
Nov 8, 2019Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
Active
Apr 6, 2018Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
Active
Oct 1, 2015Boiler LBLVIO
VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
Active
Dec 31, 2009Boiler LBLVIO
Active
Jan 1, 2009Boiler LL6291
Active
HPD (1) · C 1 · B 0 · A 0
IssuedClassViolationCorrect by
Aug 19, 2008CSECTION 27-2005 ADMIN. CODE: PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE METAL CORNICE ON ROOF AT NORTH, LOOSE AND HANGING OVER SUBWAY STATION.Aug 25, 2008

Check the agency records

Always confirm on the city's own systems before acting: DOB BIS property profile · DOB NOW · HPD Online · Pay ECB/OATH penalties (CityPay)

City records as of Oct 23, 2026, 10:59 AM ET. BBL 3049300001.