7 floors · 24 apartments · 32,956 sq ft · built 1891 · class D1 · owner of record: Pinta Associates Llc
New violations the morning after they're issued, plus deadline reminders. Free for one building.
| Requirement | Due | Status |
|---|---|---|
| Annual parapet observation Check Local Law 126 · By December 31 each year What this isIf the building has a parapet facing a street, sidewalk or other public way, a competent person (such as a mason, engineer or architect) must observe it every year and the owner keeps the report for DOB on request. Detached one- and two-family homes are exempt. Agency page | Dec 31, 2026 in 58 days | Keep the report on file (not filed with DOB) |
| Bedbug annual filing Applies Local Law 69 · December 1 to 31 each year What this isOwners of multiple dwellings file their bedbug infestation history for the prior year with HPD and post or distribute it to tenants. Agency page | Dec 31, 2026 in 58 days | Annual |
| Annual notice: window guards and lead paint Applies HPD / Health Code · January 1 to 16 each year What this isDeliver the annual notice to every unit asking whether a child lives there (window guards for children 10 and under; lead paint for children under 6 in pre-1960 buildings), then follow up on units that don't return it by mid-February. Agency page | Jan 16, 2027 in 74 days | Annual |
| Energy and water benchmarking Likely applies Local Law 84 · May 1 each year What this isBuildings over 25,000 sq ft (this lot shows 32,956 sq ft) report energy and water use for the prior calendar year through ENERGY STAR Portfolio Manager. The city's Covered Buildings List is the final word on which buildings must file. Agency page | May 1, 2027 in 179 days | Annual filing |
| Building emissions report Likely applies Local Law 97 · May 1 each year (extensions available) What this isCovered buildings file an annual greenhouse gas emissions report certified by a registered design professional. Buildings over their emissions limit owe penalties, so it pays to check early. Agency page | May 1, 2027 in 179 days | Annual filing |
| Annual property registration Applies HPD registration · September 1 each year What this isResidential buildings with three or more units, and one- and two-family homes the owner doesn't occupy, register with HPD every year ($13 fee). An unregistered building can't start a nonpayment case in Housing Court and faces civil penalties. Agency page | Sep 1, 2027 in 302 days | Registered through 2027-09-01 |
| Facade inspection report (Cycle 10B) Applies Local Law 11 / FISP · Feb 21, 2026 to Feb 21, 2028 What this isBuildings taller than six stories file a facade inspection report by a QEWI once every five-year cycle. Tax blocks ending in 0, 7 or 8 are in sub-cycle 10B. DOB facade records for this building show $1,864,800 in late-filing or failure-to-file penalties. Agency page | Feb 21, 2028 in 475 days | No Cycle 10 report on record yet |
| Gas piping inspection (2029 cycle) Likely applies Local Law 152 · During 2029 What this isBuildings with gas piping (except one- and two-family homes) need a periodic gas piping inspection by a licensed master plumber every four years. Community district 7 is on the 2029 cycle; certification is filed with DOB after the inspection. Buildings with no gas piping file a certification instead. Agency page | Dec 31, 2029 in 1154 days | Next cycle year 2029 |
| Annual boiler inspection (2 boilers) Applies Boiler inspection · By December 31 each year What this isBoilers are inspected each calendar year and the report is filed in DOB NOW: Safety within 14 days of the inspection (low-pressure boilers in residential buildings of 5 or fewer families are exempt). Latest report on record: 2026-07-23 (Accepted). Agency page | On file | 2026 reports accepted |
| Issued | Violation | Hearing | Balance |
|---|---|---|---|
| Apr 20, 2026 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7B, 8B, AND 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #903461. AGG1: PRIOR NOV 37026343H #37036481P | Jul 16, 2026 DEFAULT | $10,000 |
| Mar 2, 2026 | Unknown CLASS - 2 3314.1 AT INSPECTION OF A 7 STORIES BUILDING UNDER FACADE REPAIR I OBSERVED PIPE SCAFFOLD ERECTED ON THE SITE WITH NO SIGN OF ANY EXTERIOR WORK GOING ON. I OBSERVED TORN AND DISCONNECTED DEBRIS SAFETY NETTING A #39551076K | Jan 15, 2027 | $2,500 |
| Jul 28, 2025 | Construction CLASS - 2 AT TIME OF INSPECTION OF 7 STORY MIXED USE BUILDING WITH SIDEWALK SHED IN PLACE NOT MAINTAINED PER CODE SPECIFICATIONS HAVING 5' WIDTH CLEARANCE FOR PEDESTRIANS AND COVER FULL WIDTH OF SIDEWALK/VERTICAL MEMBERS #39542912M | Oct 19, 2026 IN VIOLATION | $2,400 |
| May 23, 2025 | Elevators CLASS - 1 CLASS 1 (CU):DOOR ZONE RESTRICTOR INOPERATIVE (CU).REPAIR THE DEVICE AND CONTACT NYC DOB BY EMAILING EIR@BUILDINGS.NYC.GOV TO SCHEDULE A RE-INSPECTION TO HAVE THE CEASE USE ORDER LIFTED. #39148866P | Jul 31, 2025 DEFAULT | $6,250 |
| Sep 25, 2024 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR FACADE AND APPURTENANCES NOTES;CRACKED/DISPLACED BRICK MASONRY BETWEEN 5TH AND 6TH STORY AT EXPOSURE#1 SOUTH ELEVATION.DEFORMED METAL WINDOW FRAME AT 5TH STORY AT EXPOSURE#1 SOUTH.R #35686626Z | Feb 6, 2025 DEFAULT | $6,250 |
| Jan 16, 2024 | Local Law CLASS - 2 FAILURE TO FILE ACCEPTABLE AMENDED CYCLE 7B, 8B, AND 9B REPORT INDICATING CORRECTION OF UNSAFE CONDITIONS DESCRIBED IN INITIAL FACADES IN INITIAL FACADES REPORT REQUIRED BY 28-302.5 FOR CONTROL #903461. REMEDY: #37026343H | Jun 20, 2024 IN VIOLATION | $0 |
| Jul 6, 2023 | Elevators CLASS - 1 FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. SERVICE ELEVATOR EQUIPMENT AS PER BC3001.2 & 27-987. UPON INSPECTION, THE DEVICE IS FOUND TO BE OUT OF SERVICE, CREATING A HAZARDOUS CONDITION PER 1RCNY 11 #39089789N | Oct 12, 2023 IN VIOLATION | $3,125 |
| Jun 14, 2023 | Elevators CLASS - 1 97:X:10; ENTIRE DEVICE IS NOT OPERATING, NEEDS TO BE REPAIRED. #39088545M | Sep 28, 2023 IN VIOLATION | $1,250 |
| Jan 20, 2023 | Elevators CLASS - 1 CLASS 1 CEASE USE ITEMS;;;; PROVIDE WORKING ALARM BELL THRU THE STOP SWITCH AND A SEPERATE DEVICE TO ACTUATE ALARM SIGNAL. RENDER OPERATIVE THE DOOR ZONE RESTRICTOR. THIS IS A SAFETY DEVICE TO ENSURE PASSENGERS #39078104H | Mar 30, 2023 ADMIT/IN-VIO | $0 |
| Dec 19, 2022 | Elevators CLASS - 1 CLASS 1: 97.X.10 RESTORE TO SERVICE REPAIR IMMEDIATLY & CALL NYCDOB FOR INSPECTION. #39075934N | Feb 23, 2023 DEFAULT | $6,250 |
| Sep 1, 2022 | Elevators CLASS - 1 V/F CLASS 1 CAR CEASE USE 2/X10 OUT SIDE COMM INOPERATIVE REPAIR,1/L/10 EMERGENCY STOP SWITCH BELL DOES NOT RING WHEN ACTIVATED DEFECTED REPAIR DLM IMPROPERLY INSTALLED ON THIS DEVICE. NO FIREMANS SERVICE PRESE #39069302Y | Oct 20, 2022 DEFAULT | $6,250 |
| Jun 1, 2021 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7B & 8B REPORT OF CRITIAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#803461. AGG2 HISTORY OF NONCOMPLIANCE #37021426K | Oct 7, 2021 DEFAULT | $10,000 |
| Mar 18, 2021 | Elevators CLASS - 1 DLM NOT WORKING REPAIR ,CAR DOOR RESTRICTOR MISSING PROVIDE CONTROLLER BOARD INSTALL 5/24/83. MACHINE ROOM WHEEL HOUSE MISSING LIGHT AND STOP SWITCH ,TOP A CAR MISSING STOP SWITCH PROVIDE. #39037875P | Jun 17, 2021 IN VIOLATION | $1,250 |
| Feb 16, 2021 | Elevators CLASS - 1 FOUND DLM UNIT ARE NOT CONNECTED WITH MAIN CONTOLLER OF THE ELEVATOR I.E. DLM NOT WORKING. WORK PERMIT FOR FURNISHING AND INSTALLING DLM EXPIRED. PERMIT NUMBER : M00295782-I1-VT. EXPIRED ON 07/27/2020. PERFORM #39036277K | Apr 8, 2021 DEFAULT | $3,125 |
| May 20, 2020 | Local Law CLASS - 2 FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 7B & 8B REPORT CRITICALEXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL & APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#803461. AGG2 HISTORY OF NONCOMPLIANCE ON #37019022L | Aug 27, 2020 DEFAULT | $10,000 |
| Oct 15, 2018 | Local Law CLASS - 2 FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#803461. REMEDY: SUBMIT REQUIRED TECHNICAL REPORT #37012772Z | May 2, 2019 IN VIOLATION | $0 |
| Jun 25, 2018 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING FACADE AND APPURTENANCES. *SOUTHAND WEST ELEVATIONS, EXP1 AND 2 OBSERVED BROKEN OFF/DAMAGED AND LOOSE PCS OF DECORATIVE STONES ON VARIOUS FLOORS ON VARIOUS LOCATIONS.RMDY: #35319250P | Oct 4, 2018 IN VIOLATION | $0 |
| Nov 16, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG SOUTH ELEV EXP#1 DECORATIVE MASONRY BANS CHIPPED CRACKED BROKEN OFF-MISSING BRICK(6 FL)ASPHALT ROOFING TILES DEFECTIVE/BROKEN CHIPPED WEST ELEV EXP#2 DECORATIVE MASONRY BANS #35174019H | Jan 26, 2017 WRITTEN OFF | $0 |
| Aug 11, 2016 | Local Law CLASS - 2 FAILURE TO SUBMIT ACCEPTABLE 7TH ROUND REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALLS & APPURTENANCES REQUIRED BY 28-302.4. AGG2 HISTORY OF NONCOMPLIANCE ON 36023389N(AGG1),36019568R. #37001046K | Mar 2, 2017 WRITTEN OFF | $0 |
| Aug 10, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BLDG SOUTH ELEV EXP#1 HORIZONTAL MASONRY BANS CHIPPED & BROKEN OFF-CHIMNEY SPALLING,BRICK ERODED MASONRY. SOUTHEAST PARAPET(BULGING)AT TRANSITIONAL MATERIAL(CONCRETE/STONE TO BRICK) #35170589L | Sep 29, 2016 WRITTEN OFF | $0 |
| Jan 21, 2016 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING SOUTH ELEV EXP1 - 6 FLOOR BAN AND CRACKED 7 FLOOR BAN BULGING-LOOSE ASPHALT SHINGLES TRIM AT ROOF LINE DEFECTIVE AND DISLODGED (ABOVE ENTRANCE) PARAPET BULGING WEST ELE #35133902X | Mar 10, 2016 WRITTEN OFF | $0 |
| Oct 27, 2015 | Construction CLASS - 2 FAILURE TO MAINTAIN EXTERIOR BUILDING ROOF-LOOSE,WARN MISSING ASPHALT ROOF SHINGLES,CHIMNEY DEFECTIVE CRACKED AND MISSING MORTAR ELEV MACHINE ROOM COPING CRACKED-ROOF DRAIN LEADER MISSING CRACKED OR MISSING CAM #35133903H | Mar 10, 2016 WRITTEN OFF | $0 |
| Oct 21, 2015 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE TECHNICAL REPORT IN COMPLIANCE W/CODE PROVISIONS: PERIODIC INSPECTION PF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28.302 & THE DOB'S RULES & REGULATIONS. REMEDY: FILE #36023389N | Mar 3, 2016 WRITTEN OFF | $0 |
| Aug 11, 2015 | Construction CLASS - 1 FAILURE TO MAINTAIN BLDG WALLS OR APPURTENANCES. NOTED: A 7 STY MD W/BRICK & BROWNSTONE FACADE HAS EROSION/DISAGGREGATION OF BROWNSTONE & PIECES HAVE DETACHED & FALLEN ONTO SIDEWALK,ALSO NOTED AT SEVERAL DIFFER #35137013Y | Dec 24, 2015 IN VIOLATION | $0 |
| Jul 14, 2014 | Local Law CLASS - 2 FAILURE TO FILE AN ACCEPTABLE CYCLE 7 TECHNICAL REPORT IN COMPLIANCE WITH CODE PROVISIONS: PERIODIC INSPECTION OF EXTERIOR WALLS & APPURTENANCES AS REQUIRED BY ARTICLE 28-302 & THE DEPT OF BLDGS RULES & REGULAT #36019568R | Dec 11, 2014 IN VIOLATION | $0 |
| Issued | Violation | Status |
|---|---|---|
| Dec 11, 2024 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00124 | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00377 | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00380 | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00379 | DOB VIOLATION - ACTIVE |
| Oct 4, 2023 | FAIL TO CERTIFY CLASS 1 FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION #00378 | DOB VIOLATION - ACTIVE |
| Dec 15, 2021 | HAZARDOUS CONDITION (FACADE) CYCLE 7B UNSAFE REPORT FILED #709543 | DOB VIOLATION - ACTIVE |
| Dec 15, 2021 | FAILURE TO CORRECT SWARMP CONDITIONS (FACADE) CYCLE 9B FAILURE TO CORRECT SWARMP CONDITIONS #00139 | DOB VIOLATION - ACTIVE |
| Dec 15, 2021 | HAZARDOUS CONDITION (FACADE) CYCLE 8B UNSAFE REPORT FILED #809544 | DOB VIOLATION - ACTIVE |
| Dec 15, 2021 | HAZARDOUS CONDITION (FACADE) CYCLE 9B UNSAFE REPORT FILED #909545 | DOB VIOLATION - ACTIVE |
| Sep 15, 2017 | ELEVATOR ANNUAL INSPECTION / TEST VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2016 INSPECTION/TEST #01107 | DOB VIOLATION - ACTIVE |
| Feb 24, 2017 | LOW PRESSURE BOILER VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT #00069 | DOB VIOLATION - ACTIVE |
| Jun 1, 2016 | NON-RESIDENTIAL ELEVATOR PERIODIC INSPECTION/TEST FAILURE TO PERFORM CATEGORY 5 INSPECTION #00484 | DOB VIOLATION - ACTIVE |
| Aug 30, 2013 | NO REPORT AND / OR LATE FILING (FACADE) FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012 #00506 | DOB VIOLATION - ACTIVE |
| Nov 30, 2007 | LOCAL LAW 11/98 - FACADE #NRF43074 | DOB VIOLATION - ACTIVE |
| Aug 8, 2002 | LOCAL LAW 11/98 - FACADE #NRF50951 | DOB VIOLATION - ACTIVE |
| Issued | Violation | Status |
|---|---|---|
| Mar 17, 2026 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 10, 2025 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2024 Cat1 Test Affirmation of Correction | Active |
| Dec 11, 2024 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 11, 2024 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2023 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2020 Cat1 Test Affirmation of Correction | Active |
| Oct 23, 2023 | Elevators FTC-VT-CAT1-CO Violation Issued-Failure To File 2022 Cat1 Test Affirmation of Correction | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Oct 4, 2023 | AEUHAZ FTC-AEU-HAZ | Active |
| Dec 15, 2021 | Facades FISPHAZ CYCLE 7B UNSAFE REPORT FILED | Active |
| Dec 15, 2021 | Facades FISPHAZ CYCLE 9B UNSAFE REPORT FILED | Active |
| Dec 15, 2021 | Facades FISPFCS CYCLE 9B FAILURE TO CORRECT SWARMP CONDITIONS | Active |
| Dec 15, 2021 | Facades FISPHAZ CYCLE 8B UNSAFE REPORT FILED | Active |
| Jul 31, 2018 | Facades FISPNRF FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018 | Active |
| Sep 15, 2017 | Elevators EVCAT1 | Active |
| Feb 24, 2017 | Boiler LBLVIO VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT | Active |
| Jun 1, 2016 | Elevators EVCAT5 | Active |
| Aug 30, 2013 | Facades FISPNRF FAILED TO FILE FISP CYCLE 7B TECHNICAL REPORT BY 08/21/2012 | Active |
| Nov 30, 2007 | Facades LL1198 CYCLE 6 NO REPORT FILED | Active |
None open.